0
eRRU Installation Modes
Installing the eRRU on a Pole
b
Normal pole
推荐抱杆直径值为
80mm
c
Common Requirements
a
Special pole
mm
In this document, eRRU3232 is used as an example. Difference in
installation and operation of other eRRU products are also described
.
CAUTIO
N
• In all scenarios, the eRRU must be installed vertically.
• Do not stand the eRRU upright because the load-bearing capacity of the RF ports at the bottom of the eRRU is low.
• Place a foam pad or cardboard on the ground to protect the housing of the eRRU from damage before the binding.
Installing the Mounting Kits on the Wall
eRRU Installation Process
• For a single RRU, the wall can bear four
times of the weight of an RRU.
• Expansion bolts must be tightened to 30 N·m
to ensure that the bolts work properly and the
wall remains intact without cracks in it.
NOTE
Before installing the RRU, check the RRU and
accessories based on the equipment packing list and
ensure that all materials are complete.
NOTE
Start
End
Conduct power-on check
(slide 14)
Check the hardware
installation (slides 13 and 14)
Install RRU cables (slides 8
to 13)
Unpack and Inspect the
Equipment
Install eRRUs on a
pole (slides 4 and
5)
Install eRRUs on
the wall (slide 6)
eRRU Quick Installation Guide
V100R005C00 02