No.
Data
5
Start mode and end mode of the test
6.14.2 Configuring the Jitter Server
The IP address and number of the port monitored by the server must be identical with those
configured on the client.
Context
Do as follows on the NQA server (Jitter server):
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
nqa-server udpecho
ip-address
port-number
The UDP monitoring service is configured.
Note that the IP address and port number monitored by the Jitter server should be consistent
with those configured on the client.
----End
6.14.3 Configuring the Jitter Client
This part describes how to configure the client of the jitter test.
Context
NOTE
The system supports the collection of the statistics about the maximum uni-directional transmission delay.
Do as follows on the NQA client (Jitter client):
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
(Optional) To configure the version number of Jitter packets, run the
nqa-jitter tag-version
version-number
command in the system view.
If Version 2 is adopted, after collecting the packet loss across a uni-directional link is enabled,
you can find the packet loss across the link from the source to the destination (or from the