Rubber pads

φ8 Drill bit

M6 plug bolt

90

M4

ETSI cabinet (21 inch)

1U

1U=44.45mm

>=1U

M6

Install the device in a cabinet.

Fix the captive nuts.

● When the ground screw is located on one side of the switch, the ground cable cannot be connected when the switch is in a cabinet. Connect the 
   ground cable before installing the switch in the cabinet.
● The S6700 chassis is 420 mm in depth. To fix the S6300 chassis securely in a rack, install guide rails in the rack.
● When the 220 mm depth chassis of an S2700 or S3700 is installed in a cabinet, use two screws to install the rack-mounting ear onto the chassis.
● The dimensions of RPS1800 chassis are 442 mm x 310 mm x 43.6 mm (W x D x H) and can be installed only in a 19-inch IEC cabinet.
● The RPS1800 can use only short rack-mounting ears, which are installed at two ends and middle of each side.

Install the plug bolt.

Install the device on the wall.

Fix the rack-mounting ears.

Mark the hole locations on the wall according to 

the device installed with rack-mounting ears.

Adhibit the rubber pads.

Install the device on a worktable.

● The power supplies and fan modules are hot swappable, but service cards are not. (The service cards of S5700-28C-HI, S5700-28C-HI-24S, 
   S5710-28C-EI, and S5710-52C-EI are hot swappable.)

●  A 4-port GE optical interface card or 4-port 10GE optical interface card must be installed together with an external channel card (except on 
    an S5700-28C-HI or S5700-28C-HI-24S). Otherwise, the interface card cannot work.
●  Remove blank panels before installing service modules.

Installation of the front-access 

service module.

Installtion of the rear-access 

service module.

Installation of the power 

supply module.

Removal of the power 

supply module.

● Before installation, take ESD-preventive measures, for example, wear ESD-preventive gloves or a wrist strap.
● When the devices without fans are piled, ensure that the distance between each two devices is no less than 1U.
● Leave at at least 50 mm space beside and behind the chassis to allow for cooling air circulation.
● The AC terminal loose-proof pinch is used only when the switch is placed on a desk or wall-mounted.

IEC cabinet (19 inch)

IEC cabinet (19 inch) IEC cabinet (19 inch)

IEC cabinet (19 inch)

Fix the rack-mounting ears.

M4

M4

M4

M4

S2700-9TP-SI/EI

S5710-EI

A

B

D

E

C

1

2

3

Huawei Technologies Co., Ltd.

Address: Administration Building,

               Huawei Technologies Co., 

               Ltd.,Bantian, Longgang

               District,Shenzhen,People’s

               Republic of China

Email: [email protected]

Website: http://www.huawei.com

Postcode: 518129

S2700/3700/5700/6700 

Series Ethernet Switches

S2700/3700/5700/6700 

Series Ethernet Switches

S2700/3700/5700/6700 

Series Ethernet Switches

Accessories

Service and Support

Precautions

Installing the Device in a Cabinet

Tool List

Installing the Device on a Worktable

The S6700 cannot be placed on a worktable

Installing the Device on a Wall

Installing and Removing the Modules

Part number: 31504991

Rev: 07

The device model is on the product nameplate.

●  The S6700 and S5710-EI cannot be wall-mounted.
●  To prevent injuries, check that there is no electrical wire at the locations to be drilled before drilling holes in the wall.
●  When the 220 mm depth chassis of an S2700 or S3700 is mounted on the wall, use two screws to install the rack-mounting ear onto the chassis.
●  When a device is mounted to the wall, the front panel must face down to prevent water.
●  Ensure that there are no flammable or explosive materials near the switch and no sundries within 100 mm around the switch.

Quick Installation Guide

Quick Installation Guide

Percussion drill

(φ8 Drill bit)

M6 Plug bolt

Marker pen

Crosshead 

screwdriver

Flathead 

screwdriver

Diagonal pliers

ESD-preventive

Claw hammer

Adjustable 

spanner

Cable tie

Optical fiber 

bundling tape

        Rear 

rack-mounting 

 ear(S5710 -EI)

           Long

rack-mounting ear

           Short

rack-mounting ear

       Front 

rack-mounting 

ear(S5710 -EI)

Rubber pads

Captive nut

M6 screw

M4 screw

    AC terminal 

loose-proof pinch

Отзывы: