Attribute
Alarm ID
Alarm Severity
Alarm Type
65541
Major
Fault alarm
Parameter
Parameter
Description
Frame
Subrack number of the EDFA
Slot
Slot number of the EDFA
PUMP
PUMP ID. Value: 2
the pump current
Actual current of EDFA PUMP2
Impact on the System
The EDFA service life is affected.
Possible Cause
The current in PUMP2 exceeds the current alarm threshold.
Handling Procedure
Check whether the current alarm threshold is set to a proper value. If it is set to a proper
value, contact Huawei.
Alarm Clearing Condition
When the current of EDFA PUMP2 drops below the preset alarm threshold, the alarm is
cleared.
2.3.3.4 ALM-65542 EDFA PUMP2 Temperature Alarm
Description
The temperature of PUMP2 exceeds the upper threshold.
The temperature of PUMP2 is below the lower threshold.
Alarms are generated for both scenarios.