Attribute
Alarm ID
Alarm Severity
Alarm Type
65540
Critical
Fault alarm
Parameter
Parameter
Description
Frame
Subrack number of the EDFA
Slot
Slot number of the EDFA
PUMP
PUMP ID. Value: 1
current pump
temperature
Actual temperature of EDFA PUMP1
Impact on the System
The EDFA service life is affected.
Possible Cause
The temperature of PUMP1 exceeds the upper threshold.
The temperature of PUMP1 is below the lower threshold.
Handling Procedure
Check whether the temperature alarm threshold is set to a proper value. If it is set to a proper
value, contact Huawei.
Alarm Clearing Condition
When the temperature of PUMP1 is between the upper and lower thresholds, the alarm is
cleared.