Figure 4-16
Appearance of the SFUI-200-C
Panel
shows the appearance of the panel.
Figure 4-17
Appearance of the panel
1. Ejector lever
2. ACT indicator
3. OFL button
4. OFL indicator
5. RUN indicator
describes the buttons and indicators on the panel of the SFU.
Table 4-11
Buttons and indicators on the panel of the SFUI-200-C
LED
Description
RUN
Before the registration of the SFU: If the green indicator blinks twice each
second (2 Hz), the system is in the alarm state.
After the registration of the SFU: If the green indicator blinks once every two
seconds (0.5 Hz), the system is running normally.
ACT
If the green indicator is on, it indicates that the SFU is working normally; if the
green indicator is off, it indicates that the SFU is faulty.
OFFLINE
When the SFU is working normally, the OFL indicator is off. After the OFL
button is pressed to power off the SFU, the OFL indicator is on.
HUAWEI CX600-8/16/X3/X8/X16 Metro Service Platform
Hardware Description
4 CX600-X8
Issue 03 (2013-11-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
94