manualshive.com logo in svg
background image

CloudEngine 7800&6800&5800 Series Switches

Hardware Description

Issue

16

Date

2015-08-26

HUAWEI TECHNOLOGIES CO., LTD.

Содержание CE6810-32T16S4Q-LI

Страница 1: ...CloudEngine 7800 6800 5800 Series Switches Hardware Description Issue 16 Date 2015 08 26 HUAWEI TECHNOLOGIES CO LTD ...

Страница 2: ...cument may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject to change without notice Every effort has been made in the preparation of this d...

Страница 3: ...nce engineers l System maintenance engineers Symbol Conventions The symbols that may be found in this document are defined as follows Symbol Description Indicates an imminently hazardous situation which if not avoided will result in death or serious injury Indicates a potentially hazardous situation which if not avoided could result in death or serious injury Indicates a potentially hazardous situ...

Страница 4: ...are grouped in braces and separated by vertical bars One item is selected x y Optional items are grouped in brackets and separated by vertical bars One item is selected or no item is selected x y Optional items are grouped in braces and separated by vertical bars A minimum of one item or a maximum of all items can be selected x y Optional items are grouped in brackets and separated by vertical bar...

Страница 5: ...led on the device Change History Changes between document issues are cumulative The latest document issue contains all the changes made in earlier issues Issue 16 2015 08 26 This version has the following updates The following information is modified l 2 Chassis l 3 Power Module l 4 Fan Module Issue 15 2015 06 10 This version has the following updates The following information is modified l 2 3 Ap...

Страница 6: ... following information is modified l 2 3 Appearance and Structure l 5 8 AOC Cable Issue 10 2014 09 20 This version has the following updates The following information is added l CE6810 48S4Q LI l CE6810 48S LI Issue 09 2014 08 01 This version has the following updates The following information is modified l 1 Version Support for Components l 3 Power Module l 4 Fan Module Issue 08 2014 04 21 This v...

Страница 7: ...e following updates The following information is modified l 3 Power Module Issue 03 2013 08 01 This version has the following updates The following information is added l 3 4 350 W DC Power Module l 3 5 600 W AC Power Module l 4 2 FAN 40SB Series Fan Modules l 5 2 DC Power Cable The following information is modified l 2 Chassis l 6 Optical Module Issue 02 2013 04 20 This version has the following ...

Страница 8: ...e 01 2013 03 15 Initial commercial release CloudEngine 7800 6800 5800 Series Switches Hardware Description About This Document Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd vii ...

Страница 9: ...ering Information 97 3 Power Module 105 3 1 150 W AC Power Module PAC 150WA 106 3 2 150 W AC Power Module ES0W2PSA0150 110 3 3 350 W AC Power Module 113 3 4 350 W DC Power Module 118 3 5 600 W AC Power Module 123 3 6 600 W AC 240 V DC Power Module 128 3 7 600 W High Voltage DC Power Module 134 4 Fan Module 139 4 1 FAN 40EA Series Fan Modules 140 4 2 FAN 40SB Series Fan Modules 143 4 3 FAN 40HA Ser...

Страница 10: ... 6 Network Cable 167 5 7 Optical Fiber 172 5 8 AOC Cable 179 5 9 Copper Cable 180 6 Optical Module 185 6 1 Concepts 186 6 2 SFP SFP Modules 188 6 3 QSFP Modules 203 CloudEngine 7800 6800 5800 Series Switches Hardware Description Contents Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd ix ...

Страница 11: ...ftware versions released for the CE7800 6800 5800 series switches 1 1 Components Available in V100R001C00 1 2 Components Available in V100R002C00 1 3 Components Available in V100R003C00 1 4 Components Available in V100R003C10 1 5 Components Available in V100R005C00 1 6 Components Available in V100R005C10 CloudEngine 7800 6800 5800 Series Switches Hardware Description 1 Version Support for Componen...

Страница 12: ...al ports 4 10GE SFP optical ports 2 40GE QSFP optical ports cannot be split into four 10GE ports Available Power Modules Table 1 2 lists the power modules available in V100R001C00 Table 1 2 Power modules available in V100R001C00 Power Module Type Power Module Power Description AC power module PAC 150WA 150 W AC power module natural heat dissipation PAC 350WA B 350 W AC power module air exhaust on ...

Страница 13: ...GE QSFP optical ports can be split into four 10GE ports CE6850 48T4Q EI 52 total 48 10GBASE T Ethernet electrical ports 4 40GE QSFP optical ports can be split into four 10GE ports CE5800 CE5810 24T4S EI 28 total 24 10 100 1000BASE T Ethernet electrical ports 4 10GE SFP optical ports CE5810 48T4S EI 52 total 48 10 100 1000BASE T Ethernet electrical ports 4 10GE SFP optical ports CE5850 48T4S2Q EI 5...

Страница 14: ... panel DC power module PDC 350WA B 350 W DC power module air exhaust on front panel PDC 350WA F 350 W DC power module air intake on front panel Available Fan Modules Table 1 6 lists the fan modules available in V100R002C00 Table 1 6 Fan modules available in V100R002C00 Series Model Description FAN 40EA FAN 40EA B FAN 40EA air exhaust on front panel FAN 40EA F FAN 40EA air intake on front panel FAN...

Страница 15: ...T4Q EI 52 total 48 10GBASE T Ethernet electrical ports 4 40GE QSFP optical ports can be split into four 10GE ports CE5800 CE5810 24T4S EI 28 total 24 10 100 1000BASE T Ethernet electrical ports 4 10GE SFP optical ports CE5810 48T4S EI 52 total 48 10 100 1000BASE T Ethernet electrical ports 4 10GE SFP optical ports CE5850 48T4S2Q EI 54 total 48 10 100 1000BASE T Ethernet electrical ports 4 10GE SFP...

Страница 16: ...50WA B 350 W DC power module air exhaust on front panel PDC 350WA F 350 W DC power module air intake on front panel Available Fan Modules Table 1 9 lists the fan modules available in V100R003C00 Table 1 9 Fan modules available in V100R003C00 Series Model Description FAN 40EA FAN 40EA B FAN 40EA air exhaust on front panel FAN 40EA F FAN 40EA air intake on front panel FAN 40SB FAN 40SB B FAN 40SB ai...

Страница 17: ...ical ports can be split into four 10GE ports CE6850 48S4Q EI 52 total 48 10GE SFP optical ports 4 40GE QSFP optical ports can be split into four 10GE ports CE6850 48T4Q EI 52 total 48 10GBASE T Ethernet electrical ports 4 40GE QSFP optical ports can be split into four 10GE ports CE6810 48S4Q LI 52 total 48 10GE SFP optical ports 4 40GE QSFP optical ports can be split into four 10GE ports CE6810 48...

Страница 18: ...available in V100R003C10 Power Module Type Power Module Power Description AC power module PAC 150WA 150 W AC power module natural heat dissipation PAC 350WA B 350 W AC power module air exhaust on front panel PAC 350WA F 350 W AC power module air intake on front panel PAC 600WA B 600 W AC power module air exhaust on front panel PAC 600WA F 600 W AC power module air intake on front panel DC power mo...

Страница 19: ...lable Models Table 1 13 lists the switch models available in V100R005C00 Table 1 13 Models available in V100R005C00 Series Model Maximum Number of Ports Supported and Port Description CE7800 CE7850 32Q EI 32 total 32 40GE QSFP optical ports can be split into four 10GE ports CE6800 CE6810 48S4Q EI 52 total 48 10GE SFP optical ports 4 40GE QSFP optical ports can be split into four 10GE ports CE6850 ...

Страница 20: ...ernet electrical ports 4 10GE SFP optical ports CE5850 48T4S2Q EI 54 total 48 10 100 1000BASE T Ethernet electrical ports 4 10GE SFP optical ports 2 40GE QSFP optical ports cannot be split into four 10GE ports CE5850 48T4S2Q HI 54 total 48 10 100 1000BASE T Ethernet electrical ports 4 10GE SFP optical ports 2 40GE QSFP optical ports can be split into four 10GE ports Available Power Modules Table 1...

Страница 21: ... on front panel High voltage DC power module PHD 600WA B 600 W high voltage DC power module air exhaust on front panel PHD 600WA F 600 W high voltage DC power module air intake on front panel Available Fan Modules Table 1 15 lists the fan modules available in V100R005C00 Table 1 15 Fan modules available in V100R005C00 Series Model Description FAN 40EA FAN 40EA B FAN 40EA series fan modules air exh...

Страница 22: ...05C10 Table 1 16 Models available in V100R005C10 Series Model Maximum Number of Ports Supported and Port Description CE7800 CE7850 32Q EI 32 total 32 40GE QSFP optical ports can be split into four 10GE ports CE6800 CE6810 48S4Q EI 52 total 48 10GE SFP optical ports 4 40GE QSFP optical ports can be split into four 10GE ports CE6850 48S4Q EI 52 total 48 10GE SFP optical ports 4 40GE QSFP optical por...

Страница 23: ... 40GE QSFP optical ports can be split into four 10GE ports CE6850U 24S2Q HI 26 total 24 10GE SFP FC optical ports 2 40GE QSFP optical ports can be split into four 10GE ports CE6810 32T16S4Q LI 52 total 32 10GBASE T Ethernet electrical ports 16 10GE SFP optical ports 4 40GE QSFP optical ports can be split into four 10GE ports CE6810 24S2Q LI 26 total 24 10GE SFP optical ports 2 40GE QSFP optical po...

Страница 24: ... SFP optical ports 2 40GE QSFP optical ports can be split into four 10GE ports Available Power Modules Table 1 17 lists the power modules available in V100R005C10 Table 1 17 Power modules available in V100R005C10 Power Module Type Power Module Power Description AC power module PAC 150WA 150 W AC power module natural heat dissipation ES0W2PSA0150 150 W AC power module natural heat dissipation PAC 3...

Страница 25: ...100R005C10 Table 1 18 Fan modules available in V100R005C10 Series Model Description FAN 40EA FAN 40EA B FAN 40EA series fan modules air exhaust on front panel FAN 40EA F FAN 40EA series fan modules air intake on front panel FAN 40SB FAN 40SB B FAN 40SB series fan modules air exhaust on front panel FAN 40SB F FAN 40SB series fan modules air intake on front panel FAN 40HA FAN 40HA B FAN 40HA series ...

Страница 26: ...FAN 040A series fan modules air exhaust on front panel FAN 040A F FAN 040A series fan modules air intake on front panel CloudEngine 7800 6800 5800 Series Switches Hardware Description 1 Version Support for Components Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 16 ...

Страница 27: ...ng 2 3 Appearance and Structure 2 4 Indicators 2 5 Ports 2 6 Specifications 2 7 Ordering Information CloudEngine 7800 6800 5800 Series Switches Hardware Description 2 Chassis Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 17 ...

Страница 28: ...oes not provide special functions U The product supports the unified port function D Number and type of downlink interfaces l T GE 10GBase T electrical interfaces l S GE 10GE SFP optical interfaces l Q quad small form factor pluggable plus QSFP optical interfaces E Number and types of uplink interfaces l T GE 10GBase T electrical interfaces l S GE 10GE SFP optical interfaces l Q QSFP optical inter...

Страница 29: ...er versions CE6810 24S2Q LI V100R005C10 and later versions CE6850 CE6850 48S4Q EI V100R001C00 and later versions CE6850 48T4Q EI V100R001C00 and later versions CE6850 48S6Q HI V100R005C00 and later versions CE6850 48T6Q HI V100R005C10 and later versions CE6851 48S6Q HI V100R005C10 and later versions CE6850U 48S6Q HI V100R005C10 and later versions CE6850U 24S2Q HI V100R005C10 and later versions CE5...

Страница 30: ...0 32Q EI STATUS STATUS STATUS STATUS 9 1 2 3 4 5 678 10 10 11 11 12 12 12 12 13 10 10 Front power supply side Rear port side Left side Right side 11 11 1 Power supply slot 1 Applicable power modules l 600 W AC power module 2 Power supply slot 2 Applicable power modules l 600 W AC power module 3 Fan slot 1 Applicable fan modules l FAN 40HA series fan modules 4 Fan slot 2 Applicable fan modules l FA...

Страница 31: ...e l 10 m QSFP AOC cable QSFP to QSFP l 1 m 3 m 5 m QSFP copper cables QSFP to 4 SFP l 1 m 3 m 5 m QSFP copper cables QSFP to QSFP 10 Three port side mounting holes for mounting brackets 11 Four middle mounting holes for mounting brackets 12 Four power supply side mounting holes for mounting brackets 13 Ground screw CloudEngine 7800 6800 5800 Series Switches Hardware Description 2 Chassis Issue 16 ...

Страница 32: ...de 12 12 10 1 Power supply slot 1 Applicable power modules l 350 W DC power module l 600 W AC power module 2 Power supply slot 2 Applicable power modules l 350 W DC power module l 600 W AC power module 3 Fan slot 1 Applicable fan modules l FAN 40EA series fan modules 4 Fan slot 2 Applicable fan modules l FAN 40EA series fan modules 5 Console port 6 ETH management port RJ45 7 Barcode label NOTE Thi...

Страница 33: ... Three port side mounting holes for mounting brackets 12 Four middle mounting holes for mounting brackets 13 Four power supply side mounting holes for mounting brackets 14 Ground screw CE6810 48S4Q LI Figure 2 4 Appearance of the CE6810 48S4Q LI 1 2 3 4 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 1 2 3 4 5 6 7 8 9 10 11 12 SYS MST STA...

Страница 34: ...DM optical module l GE optical module l GE CWDM optical module l GE copper module works at 10 Mbit s 100 Mbit s or 1000 Mbit s l 3 m 10 m 20 m SFP AOC cables l 1 m 3 m 5 m 7 m active 10 m active SFP copper cables 10 Four 40GE QSFP Ethernet optical ports NOTE A 40GE QSFP port can be split into four 10GE ports Applicable modules and cables l 40GE optical module l 10 m QSFP AOC cable QSFP to QSFP l 1...

Страница 35: ...upply slot 1 Applicable power modules l 350 W DC power module l 600 W AC power module 2 Power supply slot 2 Applicable power modules l 350 W DC power module l 600 W AC power module 3 Fan slot 1 Applicable fan modules l FAN 40EA series fan modules 4 Fan slot 2 Applicable fan modules l FAN 40EA series fan modules 5 Console port 6 ETH management port RJ45 7 Barcode label NOTE This label is drawable a...

Страница 36: ...ounting brackets 13 Ground screw CE6810 32T16S4Q LI Figure 2 6 Appearance of the CE6810 32T16S4Q LI 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 SYS MST STAT SPEED STACK MODE ID CE6810 32T16S4Q LI 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 1 2 3 4 CONSOLE ETH SYS MST ACT L A ID PWR1 FAN1 FAN2 PWR2 CE6810 32T16S4Q LI STATUS PAC 600WA B STATUS PAC 600WA...

Страница 37: ...dules and cables l 10GE optical module OSXD22N00 and LE2MXSC80FF0 not supported l 10GE CWDM optical module l GE optical module l GE CWDM optical module l GE copper module works at 10 Mbit s 100 Mbit s or 1000 Mbit s l 3 m 10 m 20 m SFP AOC cables l 1 m 3 m 5 m 7 m active 10 m active SFP copper cables 11 Four 40GE QSFP Ethernet optical ports NOTE A 40GE QSFP port can be split into four 10GE ports A...

Страница 38: ...0WA B STATUS PAC 600WA B 1 Power supply slot 1 Applicable power modules l 350 W DC power module l 600 W AC power module 2 Power supply slot 2 Applicable power modules l 350 W DC power module l 600 W AC power module 3 Fan slot 1 Applicable fan modules l FAN 40EA series fan modules 4 Fan slot 2 Applicable fan modules l FAN 40EA series fan modules 5 Console port 6 ETH management port RJ45 7 Barcode l...

Страница 39: ...Three port side mounting holes for mounting brackets 12 Four middle mounting holes for mounting brackets 13 Four power supply side mounting holes for mounting brackets 14 Ground screw CE6850 48S4Q EI Figure 2 8 Appearance of the CE6850 48S4Q EI 1 2 3 4 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 1 2 3 4 5 6 7 8 9 10 11 12 SYS MST STAT...

Страница 40: ...GE optical module l GE CWDM optical module l GE copper module works at 10 Mbit s 100 Mbit s or 1000 Mbit s l 3 m 10 m 20 m SFP AOC cables l 1 m 3 m 5 m 7 m active 10 m active SFP copper cables 10 Four 40GE QSFP Ethernet optical ports NOTE A 40GE QSFP port can be split into four 10GE ports Applicable modules and cables l 40GE optical module l 10 m QSFP AOC cable QSFP to QSFP l 1 m 3 m 5 m QSFP copp...

Страница 41: ...de 12 12 10 1 Power supply slot 1 Applicable power modules l 350 W AC power module l 600 W AC power module 2 Power supply slot 2 Applicable power modules l 350 W AC power module l 600 W AC power module 3 Fan slot 1 Applicable fan modules l FAN 40EA series fan modules 4 Fan slot 2 Applicable fan modules l FAN 40EA series fan modules 5 Console port 6 ETH management port RJ45 7 Barcode label NOTE Thi...

Страница 42: ...unting holes for mounting brackets 13 Four power supply side mounting holes for mounting brackets 14 Ground screw CE6850 48S6Q HI Figure 2 10 Appearance of the CE6850 48S6Q HI 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 1 2 3 4 5 6 SYS MST CE6850 48S6Q HI ID 4 3 2 1 40GE Breakout STAT FAN 060A F STAT FAN 060...

Страница 43: ... module installed the local interface can go Up but does not support rate configuration 3 Console port 4 USB port 5 Mini USB port 6 Barcode label NOTE This label is drawable and you can pull it outward to view the barcode and MAC address of the switch 7 Fan slot 1 Applicable fan modules l FAN 060A series fan modules 8 Fan slot 2 Applicable fan modules l FAN 060A series fan modules 9 Power supply s...

Страница 44: ... QSFP 13 Three port side mounting holes for mounting brackets 1 4 Four middle mounting holes for mounting brackets 15 Four power supply side mounting holes for mounting brackets CE6850 48T6Q HI Figure 2 11 Appearance of the CE6850 48T6Q HI 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 1 2 3 4 3 4 SYS MST CE685...

Страница 45: ... module installed the local interface can go Up but does not support rate configuration 3 Console port 4 USB port 5 Mini USB port 6 Barcode label NOTE This label is drawable and you can pull it outward to view the barcode and MAC address of the switch 7 Fan slot 1 Applicable fan modules l FAN 060A series fan modules 8 Fan slot 2 Applicable fan modules l FAN 060A series fan modules 9 Power supply s...

Страница 46: ...es for mounting brackets CE6851 48S6Q HI Figure 2 12 Appearance of the CE6851 48S6Q HI 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 1 2 3 4 5 6 SYS MST CE6851 48S6Q HI ID 4 3 2 1 40GE Breakout 9 Front power supply side Rear port side Left side Right side 10 CONSOLE ETH SYS MST ACT L A ID PWR1 FAN1 FAN2 PWR2 C...

Страница 47: ...0 and LE2MXSC80FF0 not supported l 10GE CWDM optical module l GE optical module l GE CWDM optical module l GE copper module only works at 1000 Mbit s l 3 m 10 m 20 m SFP AOC cables l 1 m 3 m 5 m 7 m active 10 m active SFP copper cables 10 Six 40GE QSFP Ethernet optical ports NOTE A 40GE QSFP port can be split into four 10GE ports Applicable modules and cables l 40GE optical module l 10 m QSFP AOC ...

Страница 48: ...tical port of the combo port l FE optical module l GE optical module l GE CWDM optical module NOTE The combo optical port uses a 100M or GE optical module and matching fibers A 100M optical module can be used only after the switch starts successfully If a 10GE optical module is installed the interface can go Up but the system displays an alarm message indicating that the interface does not support...

Страница 49: ...l module l 10GE CWDM optical module l GE optical module l GE CWDM optical module l GE copper module only works at 1000 Mbit s l 3 m 10 m 20 m SFP AOC cables l 1 m 3 m 5 m 7 m active 10 m active SFP copper cables 1 2 Six 40GE QSFP Ethernet optical ports NOTE A 40GE QSFP port can be split into four 10GE ports Applicable modules and cables l 40GE optical module l 10 m QSFP AOC cable QSFP to QSFP l 1 ...

Страница 50: ...l module l GE optical module l GE CWDM optical module NOTE The combo optical port uses a 100M or GE optical module and matching fibers A 100M optical module can be used only after the switch starts successfully If a 10GE optical module is installed the interface can go Up but the system displays an alarm message indicating that the interface does not support the optical module If a GE copper modul...

Страница 51: ...l module l 10GE CWDM optical module l GE optical module l GE CWDM optical module l GE copper module only works at 1000 Mbit s l 3 m 10 m 20 m SFP AOC cables l 1 m 3 m 5 m 7 m active 10 m active SFP copper cables 1 2 Two 40GE QSFP Ethernet optical ports NOTE A 40GE QSFP port can be split into four 10GE ports Applicable modules and cables l 40GE optical module l 10 m QSFP AOC cable QSFP to QSFP l 1 ...

Страница 52: ... 1 Applicable power modules l 150 W AC power module PAC 150WA l 350 W DC power module 2 Power supply slot 2 Applicable power modules l 150 W AC power module PAC 150WA l 350 W DC power module 3 Fan slot 1 Applicable fan modules l FAN 40SB series fan modules 4 Fan slot 2 Applicable fan modules l FAN 40SB series fan modules 5 Console port 6 ETH management port RJ45 7 Barcode label NOTE This label is ...

Страница 53: ... screw CE5810 48T4S EI Figure 2 16 Appearance of the CE5810 48T4S EI 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 SYS MST STAT SPEED STACK MODE ID CE5810 48T4S EI 1 2 3 4 CONSOLE ETH SYS MST ACT L A ID PWR1 FAN1 FAN2 PWR2 CE5810 48T4S EI PAC 150WA 100 240V 50 60Hz 2 5A STATUS PAC 150WA 100 240V 50 60Hz 2 5A S...

Страница 54: ...of the switch 8 USB port 9 Forty eight 10 100 1000BASE T Ethernet electrical ports 10 Four 10GE SFP Ethernet optical ports Applicable transceiver modules and cables l 10GE optical module l 10GE CWDM optical module l GE optical module l GE CWDM optical module l GE copper module only works at 1000 Mbit s l 3 m 10 m 20 m SFP AOC cables l 1 m 3 m 5 m 7 m active 10 m active SFP copper cables 11 Three p...

Страница 55: ...ide Left side Right side 1 Power supply slot 1 Applicable power modules l 150 W AC power module PAC 150WA l 350 W DC power module 2 Power supply slot 2 Applicable power modules l 150 W AC power module PAC 150WA l 350 W DC power module 3 Fan slot 1 Applicable fan modules l FAN 40EA series fan modules 4 Fan slot 2 Applicable fan modules l FAN 40EA series fan modules 5 Console port 6 ETH management p...

Страница 56: ...opper cables 11 Two 40GE QSFP Ethernet optical ports NOTE A 40GE QSFP port cannot be split into four 10GE ports Applicable transceiver modules and cables l 40GE optical module l 10 m QSFP AOC cable QSFP to QSFP l 1 m 3 m 5 m QSFP copper cables QSFP to QSFP 12 Three port side mounting holes for mounting brackets 13 Four power supply side mounting holes for mounting brackets 14 Ground screw CloudEng...

Страница 57: ...Rear port side Left side Right side 1 Power supply slot 1 Applicable power modules l 150 W AC power module PAC 150WA l 350 W DC power module 2 Power supply slot 2 Applicable power modules l 150 W AC power module PAC 150WA l 350 W DC power module 3 Fan slot 1 Applicable fan modules l FAN 40EA series fan modules 4 Fan slot 2 Applicable fan modules l FAN 40EA series fan modules 5 Console port 6 ETH m...

Страница 58: ...Two 40GE QSFP Ethernet optical ports NOTE A 40GE QSFP port can be split into four 10GE ports Applicable modules and cables l 40GE optical module l 10 m QSFP AOC cable QSFP to QSFP l 1 m 3 m 5 m QSFP copper cables QSFP to 4 SFP l 1 m 3 m 5 m QSFP copper cables QSFP to QSFP 12 Three port side mounting holes for mounting brackets 13 Four power supply side mounting holes for mounting brackets 14 Groun...

Страница 59: ... side Rear port side Left side Right side 1 Power supply slot 1 Applicable power modules l 150 W AC power module ES0W2PSA0150 l 350 W DC power module 2 Power supply slot 2 Applicable power modules l 150 W AC power module ES0W2PSA0150 l 350 W DC power module 3 Fan slot 1 Applicable fan modules l FAN 040A series fan modules 4 Fan slot 2 Applicable fan modules l FAN 040A series fan modules 5 Console ...

Страница 60: ...FP copper cables 11 Two 40GE QSFP Ethernet optical ports Applicable modules and cables l 40GE optical module l 10 m QSFP AOC cable QSFP to QSFP l 1 m 3 m 5 m QSFP copper cables QSFP to 4 SFP l 1 m 3 m 5 m QSFP copper cables QSFP to QSFP NOTE A 40GE QSFP port can be split into four 10GE ports 12 Three port side mounting holes for mounting brackets 13 Four power supply side mounting holes for mounti...

Страница 61: ... side 1 Power supply slot 1 Applicable power modules l 150 W AC power module ES0W2PSA0150 l 350 W DC power module 2 Power supply slot 2 Applicable power modules l 150 W AC power module ES0W2PSA0150 l 350 W DC power module 3 Fan slot 1 Applicable fan modules l FAN 040A series fan modules 4 Fan slot 2 Applicable fan modules l FAN 040A series fan modules 5 Console port 6 ETH management port RJ45 7 Ba...

Страница 62: ...ting brackets 14 Ground screw Slot l Power supply slot The CE7800 6800 5800 series switches have two power supply slots in which power modules can be installed to provide power to the chassis A chassis can have one or two power modules Double power modules can provide a higher reliability The CE7800 6800 5800 series switches support double power modules 1 1 backup When both power modules are worki...

Страница 63: ...s and fan modules using front to back airflow are marked or Air flows into the chassis from the power supply side and flows out from the port side as shown in Figure 2 21 CE5800 as an example l Back to front airflow The power modules and fan modules using back to front airflow are marked or Air flows into the chassis from the port side and flows out from the power supply side as shown in Figure 2 ...

Страница 64: ...FAN 40EA B CONSOLE ETH SYS MST ACT L A ID PWR1 FAN1 FAN2 PWR2 CE5850 48T4S2Q EI PAC 150WA 100 240V 50 60Hz 2 5A STATUS PAC 150WA 100 240V 50 60Hz 2 5A STATUS 2 4 Indicators Table 2 3 is a quick reference table for indicators of the CE7800 6800 5800 series switches Table 2 3 Indicator quick reference table Switch Model Indicator Description CE7850 32Q EI The indicator symbols and meanings are descr...

Страница 65: ...n the CE6850 48S6Q HI The CE6850 48S6Q HI is used as an example here to describe the indicators CE6850U 48S6 Q HI CE6850U 24S2 Q HI CE6850 48T6Q HI The downlink service port indicators of the CE6850 48T6Q HI are 10GE electrical port indicators and other indicators are the same as those on the CE6850 48S6Q HI The CE6850 48S6Q HI is used as an example here to describe the indicators CE5810 24T4S EI ...

Страница 66: ...45 6 7 28 29 30 31 32 4 3 2 1 40GE Breakout 8 Figure 2 24 Indicators on the CE7850 32Q EI front panel STATUS FAN 40HA B STATUS FAN 40HA B PAC 350WA B 100 240V 50 60Hz 5A STATUS PAC 350WA B 100 240V 50 60Hz 5A STATUS CONSOLE ETH SYS MST ACT L A ID PWR1 FAN1 FAN2 PWR2 CE7850 32Q EI 9 2 1 6 10 STATUS FAN 40HA B CONSOLE ETH SYS MST ACT L A ID PWR1 FAN1 FAN2 PWR2 CE7850 32Q EI 9 2 1 6 10 CloudEngine 78...

Страница 67: ...another type of error has occurred in the stack 3 STAT STAT mode indicator Off The STAT mode is not selected Green Steady on The STAT mode default mode is selected and service port indicators show the link connection states and link activity on ports 4 SPEED SPEED mode indicator Off The SPEED mode is not selected Green Steady on The SPEED mode is selected and service port indicators show the speed...

Страница 68: ...motely to help field engineers find the device to maintain 7 Service port indicator 40GE optical port NOTE Arrowheads show the positions of ports A down arrowhead indicates a port at the bottom and an up arrowhead indicates a port at the top Meanings of service port indicators vary in different modes For details see Table 2 8 When a 40GE port is configured as four 10GE ports this indicator shows t...

Страница 69: ...status of the fourth 10GE port converted from the corresponding 40GE port The following is an example The first 40GE port shown in Figure 2 23 is split into four 10GE ports and the second 40GE port is not split l When Breakout indicator 1 is on the indicator of 40GE port 1 shows the status of the first 10GE port converted from 40GE port 1 and the indicator of 40GE port 2 still shows the status of ...

Страница 70: ... 3 4 4 3 2 1 40DE Breakout 7 8 8 9 1 2 3 4 5 6 SYS MST STAT SPEED STACK MODE ID CE6850 48T4Q EI 1 2 3 4 5 7 2 1 3 4 5 6 48 1 2 3 4 4 3 2 1 40DE Breakout 8 8 9 Figure 2 26 Indicators on the CE6850 48T4Q EI front panel STATUS FAN 40EA B STATUS FAN 40EA B PAC 350WA B 100 240V 50 60Hz 5A STATUS PAC 350WA B 100 240V 50 60Hz 5A STATUS CONSOLE ETH SYS MST ACT L A ID PWR1 FAN1 FAN2 PWR2 CE6850 48T4Q EI 10...

Страница 71: ...ports this indicator state V100R005C00 Only the CE6810 48S4Q EI and CE6850 48T4Q EI support this indicator state V100R005C10 and later versions Only the CE6810 48S4Q EI CE6810 48S4Q LI CE6810 48S LI CE6810 32T16S4Q LI CE6810 24S2Q LI and CE6850 48T4Q EI support this indicator state Amber Steady on A master election error or another type of error has occurred in the stack The CE6810 24S2Q LI CE6851...

Страница 72: ...de switch button on the front panel Mode switch button l When you press the MODE button once the SPEED indicator turns green and service port indicators show the speed of each port l When you press the MODE button a second time the STACK indicator turns green and service port indicators show the stack member ID of the local switch l When you press the button a third time the STAT indicator turns g...

Страница 73: ...tor shows the status of a 10GE port The sequence number of the indicated 10GE port is identified by indicators 40GE Breakout 1 2 3 4 on the lower right corner of the panel NOTE Each 40GE port has a single color indicator which shows the status of the 40GE port by default If a 40GE port is not split and is connected to four 10GE ports on a remote device using a one to four high speed cable the 40GE...

Страница 74: ...tatus of the fourth 10GE port converted from the corresponding 40GE port The following is an example The first 40GE port shown in Figure 2 25 is split into four 10GE ports and the second 40GE port is not split l When Breakout indicator 1 is on the indicator of 40GE port 1 shows the status of the first 10GE port converted from 40GE port 1 and the indicator of 40GE port 2 still shows the status of 4...

Страница 75: ... rear panel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 1 2 3 4 5 6 SYS MST CE6850 48S6Q HI ID 4 3 2 1 40GE Breakout 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 SYS MST CE6850 ID 1 2 3 4 47 48 1 2 3 4 5 6 4 3 2 1 40GE Breakout 5 6 CloudEngine 7800 6800 5800 Series Switches Hardware Description 2 Chassis Issue 16 2015 08 2...

Страница 76: ...ning normally Red Steady on l The system fails to start l A power module does not work normally l A fan module does not work normally 2 MST stack master slave indicator Off The switch is not a stack master Green Steady on The switch is a stack master or standalone switch 3 ID ID indicator Off The ID indicator is not used default state Blue Steady on The indicator identifies the device for maintena...

Страница 77: ...shut down Green l Steady on A link is established on the port l Blinking The port is sending or receiving data When a 40GE port is configured as four 10GE ports this indicator shows the status of a 10GE port The sequence number of the indicated 10GE port is identified by indicators 40GE Breakout 1 2 3 4 on the lower right corner of the panel NOTE Each 40GE port has a single color indicator which s...

Страница 78: ...E port indicator shows the status of the fourth 10GE port converted from the corresponding 40GE port The following is an example The first 40GE port shown in Figure 2 27 is split into four 10GE ports and the second 40GE port is not split l When Breakout indicator 1 is on the indicator of 40GE port 1 shows the status of the first 10GE port converted from 40GE port 1 and the indicator of 40GE port 2...

Страница 79: ... receiving data CE5850 48T4S2Q HI Figure 2 29 Indicators on the CE5850 48T4S2Q HI rear panel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 1 2 3 4 1 2 SYS MST STAT SPEED STACK MODE ID CE5850 48T4S2Q HI 1 40GE Breakout 2 3 4 7 8 10 9 1 2 3 4 5 6 1 2 3 4 5 SYS MST STAT SPEED STACK MODE ID CE5850 48T4S2Q HI 7 1 2...

Страница 80: ...king The system is running properly Red Steady on l The system fails to start l At least one power module does not work normally l At least one fan module does not work normally 2 MST stack master slave indicator Off The switch is not a stack master Green l Steady on The switch is a stack master or standalone switch l Blinking The switch is working in SVF mode Versions earlier than V100R005C10 Onl...

Страница 81: ...change the stack mode to STACK In this case service port indicators on the member switches show stack member IDs or leaf IDs of these switches 6 MODE ID mode switch button and ID indicator NOTE The mode switch button on the rear panel is integrated with the ID indicator There is only an ID indicator and no mode switch button on the front panel Mode switch button l When you press the MODE button on...

Страница 82: ...ice port indicator 40GE optical port NOTE Arrowheads show the positions of ports A down arrowhead indicates a port at the bottom and an up arrowhead indicates a port at the top The meaning of the service port indicators varies according to the current mode For details see Table 2 8 When a 40GE port is configured as four 10GE ports this indicator shows the status of a 10GE port The sequence number ...

Страница 83: ... is on each 40GE port indicator shows the status of the fourth 10GE port converted from the corresponding 40GE port The following is an example The first 40GE port shown in Figure 2 29 is split into four 10GE ports and the second 40GE port is not split l When Breakout indicator 1 is on the indicator of 40GE port 1 shows the status of the first 10GE port converted from 40GE port 1 and the indicator...

Страница 84: ...he port Amber l Off The port is not sending or receiving data l Blinking The port is sending or receiving data SPEED GE electrical port Off The port is not connected or has been shut down Green l Steady on The port speed is 10 100 Mbit s l Blinking The port speed is 1000 Mbit s 10GE electrical port Off The port is not connected or has been shut down Green l Steady on The port speed is 100 1000 Mbi...

Страница 85: ...eaf ID of the switch NOTE The leaf ID range supported by a switch depends on the number of downlink ports on the switch l On the CE5810 24T4S EI and CE6810 24S2Q LI downlink ports 1 to 24 indicate leaf IDs 101 to 124 If the leaf ID of the switch is larger than 124 port indicators retain the original states before the switch changes to the SVF state and do not show the leaf ID l On the CE6810 48S4Q...

Страница 86: ...he attributes of a 10GBASE T Ethernet electrical port Category 6A shielded twisted pairs are recommended for the 10GBASE T Ethernet electrical port Table 2 10 Attributes of a 10GBASE T Ethernet electrical port Attribute Description Connector RJ45 Standards compliance IEEE802 3an and IEEE802 3az Applicable cable Straight through cable and crossover cable Working mode Supported rate 100 1000 Mbit s ...

Страница 87: ...wing methods l Use a 1 m 3 m 7 m or 10 m SFP high speed cable l Use an active optical cable AOC or optical modules and optical fibers l Upgrade the system software of the CE5850EI switch to V100R005C10 or a later version 40GE QSFP Ethernet Optical Port A 40GE QSFP Ethernet optical port receives and sends services at a speed of 40 Gbit s If a 40GE port is split into four 10GE ports it must use 1 in...

Страница 88: ...ole port and Mini USB port have a cable connected the Mini USB port is used Table 2 13 Attributes of the console port Attribute Description Connector RJ45 Standards compliance RS232 Working mode Duplex Universal Asynchronous Receiver Transmitter UART Baud rate 9600 bit s 115200 bit s Default value 9600 bit s Mini USB Port The Mini USB port can connect to a configuration terminal for onsite configu...

Страница 89: ...If the optical port has an optical module installed first the optical port is used for data switching l If the electrical port has a network cable connected and is in Up state the electrical port is still used for data switching when the optical port has an optical module installed l If the optical port has an optical module installed and is in Up state the optical port is still used for data swit...

Страница 90: ...ace 1 or interface 2 in the BIOS menu Interface 1 is the default choice For details see Modify parameters l After registration of the switch succeeds If both the management ports have a cable connected and are in Up state port 1 acts as the primary management port and port 2 becomes the backup automatically The management interface number displayed on the command line interface is MEth0 0 0 regard...

Страница 91: ... and uploading or USB based deployment 2 6 Specifications Table 2 17 lists the specifications of CE7800 6800 5800 series switches CloudEngine 7800 6800 5800 Series Switches Hardware Description 2 Chassis Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 81 ...

Страница 92: ...HI 442 0 mm x 600 0 mm x 43 6 mm CE6850U 48S6Q HI 442 0 mm x 600 0 mm x 43 6 mm CE6850 48T6Q HI 442 0 mm x 600 0 mm x 43 6 mm CE6850U 24S2Q HI 442 0 mm x 600 0 mm x 43 6 mm CE6851 48S6Q HI 442 0 mm x 420 0 mm x 43 6 mm CE5810 24T4S EI 442 0 mm x 420 0 mm x 43 6 mm CE5810 48T4S EI 442 0 mm x 420 0 mm x 43 6 mm CE5850 48T4S2Q EI 442 0 mm x 420 0 mm x 43 6 mm CE5850 48T4S2Q HI 442 0 mm x 420 0 mm x 4...

Страница 93: ...HI 8 7 kg CE5810 24T4S EI 8 0 kg CE5810 48T4S EI 8 2 kg CE5850 48T4S2Q EI 8 85 kg CE5850 48T4S2Q HI 8 8 kg CE5855 48T4S2Q EI 8 4 kg CE5855 24T4S2Q EI 8 1 kg Environment parameters Temperature l Operating temperature 0 C to 40 C 0 m to 1800 m NOTE When the altitude is between 1800 m and 5000 m the highest operating temperature reduces 1 C every time the altitude increases 220 m l Storage temperatur...

Страница 94: ...ont to back airflow 48 dBA l CE6850 48S4Q EI Back to front airflow 45 dBA Front to back airflow 56 dBA l CE6850 48T4Q EI Back to front airflow 56 dBA Front to back airflow 56 dBA l CE6850 48S6Q HI Back to front airflow 52 dBA Front to back airflow 52 dBA l CE6850U 48S6Q HI Back to front airflow 52 dBA Front to back airflow 52 dBA l CE6850 48T6Q HI Back to front airflow 53 dBA Front to back airflow...

Страница 95: ...pecifications Power source type AC DC high voltage DC AC power input l Rated input voltage range 100 V AC to 240 V AC 50 60 Hz l Maximum input voltage range CE6850 48S6Q HI CE6850 48T6Q HI CE6850U 48S6Q HI and CE6850U 24S2Q HI 90 V AC to 290 V AC 47 Hz to 63 Hz CE5855 48T4S2Q EI and CE5855 24T4S2Q EI 90 V AC to 264 V AC 47 Hz to 63 Hz Other models 90 V AC to 290 V AC 45 Hz to 65 Hz DC power input ...

Страница 96: ... 380 V high voltage DC power input 188 V DC to 400 V DC Maximum input current l 150 W AC power PAC 150WA 2 5 A 90 V AC l 150 W AC power ES0W2PSA0150 3 A 90 V AC l 350 W AC power PAC 350WA series 5 A 90 V AC l 350 W DC power PDC 350WA series 11 A 38 4 V DC l 600 W AC power PAC 600WA series 9 A 90 V AC l 600 W AC 240 V DC power module PAC 600WB series 9 A 90 V AC 4 A 240 V DC l 600 W high voltage DC...

Страница 97: ...Q EI 380 W l CE6850 48S6Q HI 272 W l CE6850U 48S6Q HI 339 W l CE6850 48T6Q HI 379 W l CE6850U 24S2Q HI 282 W l CE6851 48S6Q HI 245 W l CE5810 24T4S EI 68 W l CE5810 48T4S EI 92 W l CE5850 48T4S2Q EI 133 W l CE5850 48T4S2Q HI 131 W l CE5855 48T4S2Q EI 103 W l CE5855 24T4S2Q EI 75 W CloudEngine 7800 6800 5800 Series Switches Hardware Description 2 Chassis Issue 16 2015 08 26 Huawei Proprietary and C...

Страница 98: ...00 traffic load 3 m network cables on 48 ports and QSFP cables on 4 ports double power modules l CE6850 48S6Q HI 166 W 100 traffic load SFP cables on 48 ports and QSFP cables on 6 ports double power modules l CE6850U 48S6Q HI 235 W 100 traffic load SFP cables on 48 ports and QSFP cables on 6 ports double power modules l CE6850 48T6Q HI 252 W 100 traffic load 3 m network cables on 48 ports and QSFP...

Страница 99: ...ower modules Chassis heat dissipation Maximum heat dissipation l CE7850 32Q EI 1470 BTU hr l CE6810 48S4Q EI 812 BTU hr l CE6810 48S4Q LI 812 BTU hr l CE6810 48S LI 607 BTU hr l CE6810 32T16S4Q LI 983 BTU hr l CE6810 24S2Q LI 583 BTU hr l CE6850 48S4Q EI 928 BTU hr l CE6850 48T4Q EI 1297 BTU hr l CE6850 48S6Q HI 928 BTU hr l CE6850U 48S6Q HI 1157 BTU hr l CE6850 48T6Q HI 1293 BTU hr l CE6850U 24S2...

Страница 100: ...r 100 traffic load 3 m network cables on 48 ports and QSFP cables on 4 ports double power modules l CE6850 48S6Q HI 566 BTU hr 100 traffic load SFP cables on 48 ports and QSFP cables on 6 ports double power modules l CE6850U 48S6Q HI 802 BTU hr 100 traffic load SFP cables on 48 ports and QSFP cables on 6 ports double power modules l CE6850 48T6Q HI 860 BTU hr 100 traffic load 3 m network cables on...

Страница 101: ...E6850 48S6Q HI CE6850 48T6Q HI CE6850U 48S6Q HI and CE6850U 24S2Q HI 4 kV in common mode and 2 5 kV in differential mode Other models 6 kV in common mode and 6 kV in differential mode l DC 4 kV in common mode and 2 kV in differential mode Heat dissipation Heat dissipation mode Air cooling Airflow Front to back or back to front which is determined by features of fan modules and power modules Reliab...

Страница 102: ...HI 1 5 GHz quad core l CE6850U 48S6Q HI 1 5 GHz quad core l CE6850 48T6Q HI 1 2 GHz quad core l CE6850U 24S2Q HI 1 5 GHz quad core l CE6851 48S6Q HI 1 2 GHz quad core l CE5810 24T4S EI 1 2 GHz dual core l CE5810 48T4S EI 1 2 GHz dual core l CE5850 48T4S2Q EI 1 2 GHz quad core l CE5850 48T4S2Q HI 1 2 GHz dual core l CE5855 48T4S2Q EI 1 GHz dual core l CE5855 24T4S2Q EI 1 GHz dual core CloudEngine 7...

Страница 103: ...48S6Q HI 4 GB l CE6850U 48S6Q HI 4 GB l CE6850 48T6Q HI 4 GB l CE6850U 24S2Q HI 4 GB l CE6851 48S6Q HI 2 GB l CE5810 24T4S EI 2 GB l CE5810 48T4S EI 2 GB l CE5850 48T4S2Q EI 2 GB l CE5850 48T4S2Q HI 2 GB l CE5855 48T4S2Q EI 2 GB l CE5855 24T4S2Q EI 2 GB CloudEngine 7800 6800 5800 Series Switches Hardware Description 2 Chassis Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Huawei...

Страница 104: ...6Q HI 16 MB l CE6850U 48S6Q HI 16 MB l CE6850 48T6Q HI 16 MB l CE6850U 24S2Q HI 16 MB l CE6851 48S6Q HI 16 MB l CE5810 24T4S EI 16 MB l CE5810 48T4S EI 16 MB l CE5850 48T4S2Q EI 8 MB l CE5850 48T4S2Q HI 16 MB l CE5855 48T4S2Q EI 16 MB l CE5855 24T4S2Q EI 16 MB CloudEngine 7800 6800 5800 Series Switches Hardware Description 2 Chassis Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright...

Страница 105: ...8S6Q HI 1 GB l CE6850U 48S6Q HI 1 GB l CE6850 48T6Q HI 1 GB l CE6850U 24S2Q HI 1 GB l CE6851 48S6Q HI 1 GB l CE5810 24T4S EI 512 MB l CE5810 48T4S EI 512 MB l CE5850 48T4S2Q EI 1 GB l CE5850 48T4S2Q HI 1 GB l CE5855 48T4S2Q EI 512 MB l CE5855 24T4S2Q EI 512 MB CloudEngine 7800 6800 5800 Series Switches Hardware Description 2 Chassis Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright...

Страница 106: ...d 40GE optical ports l CE6850U 48S6Q HI 10GE optical ports and 40GE optical ports l CE6850 48T6Q HI 10GE electrical ports and 40GE optical ports l CE6850U 24S2Q HI 10GE optical ports and 40GE optical ports l CE6851 48S6Q HI 10GE optical ports and 40GE optical ports l CE5810 24T4S EI 10GE optical ports l CE5810 48T4S EI 10GE optical ports l CE5850 48T4S2Q EI 10GE and 40GE optical ports l CE5850 48T...

Страница 107: ... 2009 CLASS A l IEC 61000 3 2 2005 A1 2008 A2 2009 EN 61000 3 2 2006 A1 2009 A2 2009 l IEC 61000 3 3 2008 EN 61000 3 3 2008 l CNS 13438 2006 CLASS A l VCCI V 4 2012 CLASS A l VCCI V 3 2012 CLASS A l EC Council Directive 2004 108 EC l GB9254 Safety and environmental standards compliance l 2002 95 EC 2011 65 EU l 2002 96 EC 2012 19 EU l EC NO 1907 2006 l ETSI EN 300 019 1 1 V2 1 4 l ETSI EN 300 019 ...

Страница 108: ...8T4S2Q EI Switch 2 150W Power Module 2 FAN Box Port side Intake 02356878 CE5810 48T4S EI CE5810 48T4S EI Switch 48 Port GE RJ45 4 Port 10GE SFP Without Fan and Power Module 02350EYW CE5810 48T4S EI F CE5810 48T4S EI Switch 48 Port GE RJ45 4 Port 10G SFP 2 FAN Box Port side Exhaust Without Power Module 02350EYX CE5810 48T4S EI B CE5810 48T4S EI Switch 48 Port GE RJ45 4 Port 10G SFP 2 FAN Box Port s...

Страница 109: ...dule 02359246 CE5850 HI B00 CE5850 48T4S2Q HI Switch 2 150W AC Power Module 2 FAN Box Port side Exhaust 02350FCL CE5850 HI B B00 CE5850 48T4S2Q HI Switch 2 150W Power Module 2 FAN Box Port side Intake 02350GTR CE5855 48T4S 2Q EI F CE5855 48T4S2Q EI Switch 48 Port GE RJ45 4 Port 10G SFP 2 Port 40G QSFP 2 FAN Box Port side Exhaust Without Power Module 02350GTT CE5855 48T4S 2Q EI B CE5855 48T4S2Q EI ...

Страница 110: ...tch 48 Port 10G SFP 6 Port 40GE QSFP 2 FAN Box Port side Intake Without Power Module 02350EWK CE6850 HI F B00 CE6850 48T6Q HI Switch 48 Port 10GE RJ45 6 Port 40GE QSFP 2 AC Power Module 2 FAN Box Port side Exhaust 02350EWL CE6850 HI B B00 CE6850 48T6Q HI Switch 48 Port 10GE RJ45 6 Port 40GE QSFP 2 AC Power Module 2 FAN Box Port side Intake 02350EWH CE6850 48T6 Q HI F CE6850 48T6Q HI Switch 48 Port...

Страница 111: ...24S2Q HI Switch 24 Port 10GE SFP support 2 4 8G FC 2 Port 40GE QSFP 2 AC Power Module 2 FAN Box Port side Intake 02350GTM CE6850U 24S2 Q HI F CE6850U 24S2Q HI Switch 24 Port 10GE SFP support 2 4 8G FC 2 Port 40GE QSFP 2 FAN Box Port side Exhaust Without Power Module 02350GTN CE6850U 24S2 Q HI B CE6850U 24S2Q HI Switch 24 Port 10GE SFP support 2 4 8G FC 2 Port 40GE QSFP 2 FAN Box Port side Intake W...

Страница 112: ...ide Exhaust Without Power Module 02350EXV CE6810 48S4Q EI B CE6810 48S4Q EI Switch 48 Port 10G SFP 4 Port 40G QSFP 2 FAN Box Port side Intake Without Power Module 02358856 CE6810 48S4Q EI CE6810 48S4Q EI Switch 48 Port 10GE SFP 4 Port 40GE QSFP Without Fan and Power Module 02350AQB CE6810 LI B00 CE6810 48S4Q LI Switch 2 600W AC Power Module 2 FAN Box Port side Exhaust 02350EGX CE6810 LI B B0A CE68...

Страница 113: ...SFP 2 Port 40GE QSFP 2 FAN Box Port side Intake Without Power Module 02350EWD CE6810 LI F B00 CE6810 32T16S4Q LI Switch 32 Port 10G RJ45 16 Port 10G SFP 4 Port 40G QSFP 2 AC Power Module 2 FAN Box Port side Exhaust 02350EWE CE6810 LI B B00 CE6810 32T16S4Q LI Switch 32 Port 10G RJ45 16 Port 10G SFP 4 Port 40G QSFP 2 AC Power Module 2 FAN Box Port side Intake 02350EWB CE6810 32T16 S4Q LI F CE6810 32...

Страница 114: ...R4 8 SFP 10G USR Without Fan and Power Module 02358859 CE7850 32Q EI CE7850 32Q EI Switch 32 Port 40GE QSFP Without Fan and Power Module 02359250 CE7850 EI B00 CE7850 32Q EI Switch 2 600W AC Power Module 2 FAN Box Port side Exhaust 02350EYY CE7850 32Q EI F CE7850 32Q EI Switch 32 Port 40G QSFP 2 FAN Box Port side Exhaust Without Power Module 02350FAB CE7850 32Q EI B CE7850 32Q EI Switch 32 Port 40...

Страница 115: ...tall a filler panel on the empty power supply slot l Before powering off a switch turn off all its power modules 3 1 150 W AC Power Module PAC 150WA 3 2 150 W AC Power Module ES0W2PSA0150 3 3 350 W AC Power Module 3 4 350 W DC Power Module 3 5 600 W AC Power Module 3 6 600 W AC 240 V DC Power Module 3 7 600 W High Voltage DC Power Module CloudEngine 7800 6800 5800 Series Switches Hardware Descript...

Страница 116: ... later versions CE5850 48T4S2Q HI Supported NOTE This power module is supported in V100R003C00 version and later versions CE6850 48S4Q EI CE6850 48T4Q EI CE6850 48S6Q HI CE6810 48S4Q EI CE6810 48S4Q LI CE6810 48S LI CE7850 32Q EI CE6850U 48S6Q HI CE6850 48T6Q HI CE6850U 24S2Q HI CE6851 48S6Q HI CE6810 32T16S4Q LI CE6810 24S2Q LI CE5855 48T4S2Q EI CE5855 24T4S2Q EI Not supported Appearance Figure 3...

Страница 117: ...100 240V 50 60 Hz 2 5A Function Table 3 2 describes the functions of the PAC 150WA CloudEngine 7800 6800 5800 Series Switches Hardware Description 3 Power Module Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 107 ...

Страница 118: ...limited within a range the power module automatically resumes power supply Output short circuit protection In this protection state the power module supplies power intermittently When the short circuit is removed the power module automatically resumes power supply Overtemperature protection When the temperature of the power module exceeds a specified threshold the power module stops supplying powe...

Страница 119: ...for example overvoltage overcurrent short circuit or overtemperature l Steady on The power module is working normally Specifications Table 3 4 lists the technical specifications of the PAC 150WA Table 3 4 Technical specifications of the PAC 150WA Item PAC 150WA Dimensions W x D x H 100 mm x 205 mm x 40 mm Weight 1 kg Rated input voltage 100 V AC 240 V AC 50 60 Hz Maximum input voltage 90 V AC 290 ...

Страница 120: ...0 48S LI CE6810 32T16S4Q LI CE6810 24S2Q LI CE6850 48S4Q EI CE6850 48T4Q EI CE6850 48S6Q HI CE6850 48T6Q HI CE6851 48S6Q HI CE6850U 48S6Q HI CE6850U 24S2Q HI CE7850 32Q EI Not supported CE5855 48T4S2Q EI CE5855 24T4S2Q EI Supported NOTE This power module is supported in V100R005C10 and later versions NOTE The ES0W2PSA0150 power module can only be used in the CE5855EI and cannot be used in any othe...

Страница 121: ...r supply when the input current restores to the normal range Output protection Output overvoltage protection In this protection state the power module stops supplying power intermittently When the output voltage restores to the normal range the power module automatically resumes power supply Output overcurrent protection In this protection state the power module supplies power intermittently When ...

Страница 122: ...erature of the power module The power module can automatically resume power supply when the temperature falls within the normal range Panel Figure 3 4 shows the panel of the ES0W2PSA0150 Figure 3 4 Panel of the ES0W2PSA0150 STATUS ON OFF 100 240V 50 60 Hz 3A ES0W2PSA0150 3 2 4 5 1 6 1 Captive screw 2 Handle 3 Indicator 4 Power switch 5 AC power socket 6 AC terminal locking latch Table 3 7 describe...

Страница 123: ...cations Table 3 8 lists the technical specifications of the ES0W2PSA0150 Table 3 8 Technical specifications of the ES0W2PSA0150 Item ES0W2PSA0150 Dimensions W x D x H 100 mm x 205 mm x 40 mm Weight 0 8 kg Rated input voltage range 100 V AC to 240 V AC 50 60 Hz Maximum input voltage 90 V AC to 264 V AC 47 Hz to 63 Hz Maximum input current 3 A Maximum output current 12 5 A Rated output voltage 12 V ...

Страница 124: ... EI CE6810 32T16S4Q LI CE6810 24S2Q LI Not supported Not supported CE6850 48S4Q EI Supported NOTE This power module is supported in V100R001C00 version and later versions Supported NOTE This power module is supported in V100R001C00 version and later versions CE6850 48T4Q EI Supported NOTE This power module is supported in V100R001C00 and later versions 600 W AC power modules are recommended for th...

Страница 125: ...ure 3 6 Appearance of a PAC 350WA F power module STATUS 100 240V 50 60 Hz 5A PAC 350WA F Function PAC 350WA B and PAC 350WA F power modules use different airflow designs but have the same functions Table 3 10 describes the functions of a 350 W AC power module CloudEngine 7800 6800 5800 Series Switches Hardware Description 3 Power Module Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyr...

Страница 126: ...er module automatically resumes power supply Output short circuit protection In this protection state the power module supplies power intermittently When the short circuit is removed the power module automatically resumes power supply Overtemperature protection When the temperature of the power module exceeds a specified threshold the power module stops supplying power When the temperature falls i...

Страница 127: ... describes the indicator on the 350 W AC power module panel Table 3 11 Description of the indicator on the 350 W AC power module panel Indicator Color Description STATUS power indicator Green l Off The power input is abnormal for example no input overvoltage or undervoltage or the power output is abnormal for example overvoltage overcurrent short circuit or overtemperature l Steady on The power mo...

Страница 128: ...dules include PDC 350WA B B back to front airflow air exhaust on front panel and PDC 350WA F F front to back airflow air intake on front panel Table 3 13 describes the mapping between switch models and 350 W DC power modules Table 3 13 Mapping between switch models and 350 W DC power modules Switch Model PDC 350WA B PDC 350WA F CE5810 24T4S EI CE5810 48T4S EI CE5850 48T4S2Q EI CE6850 48S4Q EI Supp...

Страница 129: ...is supported in V100R003C10 version and later versions CE5855 48T4S2Q EI CE5855 24T4S2Q EI CE6810 32T16S4Q LI CE6810 24S2Q LI CE6851 48S6Q HI Supported NOTE This fan module is supported in V100R005C10 version and later versions Supported NOTE This fan module is supported in V100R005C10 version and later versions Appearance Figure 3 9 shows the appearance of a PDC 350WA B power module and Figure 3 ...

Страница 130: ...C 350WA F power modules use different airflow designs but have the same functions Table 3 14 describes the functions of a 350 W DC power module CloudEngine 7800 6800 5800 Series Switches Hardware Description 3 Power Module Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 120 ...

Страница 131: ...r module automatically resumes power supply Output short circuit protection In this protection state the power module supplies power intermittently When the short circuit is removed the power module automatically resumes power supply Overtemperature protection When the temperature of the power module exceeds a specified threshold the power module stops supplying power When the temperature falls in...

Страница 132: ...350 W DC power module panel Table 3 15 Description of the indicator on the 350 W DC power module panel Indicator Color Description STATUS power indicator Green l Off The input power is abnormal no DC input power DC input overvoltage or DC input undervoltage or the output power is abnormal output overvoltage overcurrent short circuit or overtemperature l Steady on The power module is working proper...

Страница 133: ...um output current 29 17 A Rated output voltage 12 V Rated output power 350 W Part Number 02310PQN 02310PQP 3 5 600 W AC Power Module Version Mapping 600 W AC power modules include PAC 600WA B B back to front airflow air exhaust on front panel and PAC 600WA F F front to back airflow air intake on front panel Table 3 17 describes the mapping between switch models and 600 W AC power modules CloudEngi...

Страница 134: ... Supported NOTE This power module is supported in V100R003C00 version and later versions CE6810 48S4Q LI CE6810 48S LI Supported NOTE This fan module is supported in V100R003C10 version and later versions Supported NOTE This fan module is supported in V100R003C10 version and later versions CE6810 32T16S4Q LI CE6810 24S2Q LI CE6851 48S6Q HI Supported NOTE This fan module is supported in V100R005C10...

Страница 135: ...60 Hz 9A PAC 600WA F Function PAC 600WA B and PAC 600WA F power modules use different airflow designs but have the same functions Table 3 18 describes the functions of a 600 W AC power module CloudEngine 7800 6800 5800 Series Switches Hardware Description 3 Power Module Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 125 ...

Страница 136: ...r module automatically resumes power supply Output short circuit protection In this protection state the power module supplies power intermittently When the short circuit is removed the power module automatically resumes power supply Overtemperature protection When the temperature of the power module exceeds a specified threshold the power module stops supplying power When the temperature falls in...

Страница 137: ...19 describes the indicator on the 600 W AC power module panel Table 3 19 Description of the indicator on the 600 W AC power module panel Indicator Color Description STATUS power indicator Green l Off The input power is abnormal no AC input power AC input overvoltage or AC input undervoltage or the output power is abnormal output overvoltage overcurrent short circuit or overtemperature l Steady on ...

Страница 138: ...t power 600 W Part Number 02310PMH 02310PMJ 3 6 600 W AC 240 V DC Power Module Version Mapping 600 W AC 240 V DC power modules can receive AC inputs or 240 V high voltage inputs They are classified into two types depending on the airflow designs PAC 600WB B back to front airflow air exhaust on front panel and PAC 600WB F F front to back airflow air intake on front panel Table 3 21 describes the ma...

Страница 139: ...orted in V100R005C00 and later versions Supported NOTE This power module is supported in V100R005C00 and later versions CE6850U 48S6Q HI CE6850 48T6Q HI CE6850U 24S2Q HI Supported NOTE This power module is supported in V100R005C10 and later versions Supported NOTE This power module is supported in V100R005C10 and later versions Appearance Figure 3 17 shows the appearance of a PAC 600WB B power mod...

Страница 140: ...22 Functions of a 600 W AC 240 V DC power module Function Description Input protection Input overvoltage protection and undervoltage protection In either of the two protection states the power module stops supplying power When the input voltage restores to the normal range the power module automatically resumes power supply CloudEngine 7800 6800 5800 Series Switches Hardware Description 3 Power Mo...

Страница 141: ...uit is removed the power module automatically resumes power supply Overtemperature protection When the temperature of the power module exceeds a specified threshold the power module stops supplying power When the temperature falls into the normal range the power module automatically resumes power supply Heat dissipation l PAC 600WB B back to front airflow l PAC 600WB F front to back airflow Hot sw...

Страница 142: ...handle This velcro strap is used to bundle the power cable to the handle 5 Airflow flag l back to front airflow l front to back airflow 6 Power socket Table 3 23 describes the indicator on a 600 W AC 240 V DC power module panel CloudEngine 7800 6800 5800 Series Switches Hardware Description 3 Power Module Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd ...

Страница 143: ...ervoltage Specifications Table 3 24 describes the technical specifications of 600 W AC 240 V DC power modules Table 3 24 Technical specifications of 600 W AC 240 V DC power modules Item PAC 600WB B PAC 600WB F Dimensions W x D x H 66 0 mm x 340 0 mm x 39 6 mm Weight 1 5 kg Rated AC input voltage range 100 V AC to 240 V AC 50 60 Hz Maximum AC input voltage range 90 V AC to 290 V AC 47 Hz to 63 Hz R...

Страница 144: ...h voltage DC power modules Switch Model PHD 600WA B PHD 600WA F CE7850 32Q EI CE6810 48S4Q EI CE6810 48S4Q LI CE6810 48S LI CE6850 48S4Q EI CE6850 48T4Q EI CE5810 24T4S EI CE5810 48T4S EI CE5850 48T4S2Q EI CE5850 48T4S2Q HI CE6810 32T16S4Q LI CE6810 24S2Q LI CE6851 48S6Q HI CE5855 48T4S2Q EI CE5855 24T4S2Q EI Not supported Not supported CE6850 48S6Q HI Supported NOTE This power module is supported...

Страница 145: ...arance Figure 3 21 shows the appearance of a PHD 600WA B power module and Figure 3 22 shows the appearance of a PHD 600WA F power module Figure 3 21 Appearance of a PHD 600WA B power module STAT PHD 600WA B Figure 3 22 Appearance of a PHD 600WA F power module STAT PHD 600WA F CloudEngine 7800 6800 5800 Series Switches Hardware Description 3 Power Module Issue 16 2015 08 26 Huawei Proprietary and C...

Страница 146: ...e power module supplies power intermittently When the output current is limited within a range the power module automatically resumes power supply Output short circuit protection In this protection state the power module supplies power intermittently When the short circuit is removed the power module automatically resumes power supply Overtemperature protection When the temperature of the power mo...

Страница 147: ...ach 600 W high voltage DC power module is delivered with a velcro strap on the handle This velcro strap is used to bundle the power cable to the handle 5 Airflow flag l back to front airflow l front to back airflow 6 Power socket CloudEngine 7800 6800 5800 Series Switches Hardware Description 3 Power Module Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Lt...

Страница 148: ...ervoltage l The power output is abnormal output overcurrent output short circuit or output overvoltage Specifications Table 3 28 describes the technical specifications of 600 W high voltage DC power modules Table 3 28 Technical specifications of 600 W high voltage DC power modules Item PHD 600WA B PHD 600WA F Dimensions W x D x H 66 0 mm x 340 0 mm x 39 6 mm Weight 1 5 kg Rated voltage range of 38...

Страница 149: ...one of fan modules is removed from the chassis reinstall it into the chassis within 3 minutes 4 1 FAN 40EA Series Fan Modules 4 2 FAN 40SB Series Fan Modules 4 3 FAN 40HA Series Fan Modules 4 4 FAN 040A Series Fan Modules 4 5 FAN 060A Series Fan Modules CloudEngine 7800 6800 5800 Series Switches Hardware Description 4 Fan Module Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Hua...

Страница 150: ...0R001C00 version and later versions Supported NOTE This fan module is supported in V100R001C00 version and later versions CE5850 48T4S2Q HI CE6810 48S4Q EI Supported NOTE This fan module is supported in V100R003C00 version and later versions Supported NOTE This fan module is supported in V100R003C00 version and later versions CE6810 48S4Q LI CE6810 48S LI Supported NOTE This fan module is supporte...

Страница 151: ...4 2 Appearance of a FAN 40EA F fan module STATUS FAN 40EA F Function A FAN 40EA fan module consists of a fan tray two fans and a fan control unit FAN 40EA B and FAN 40EA F fan modules use different airflow designs but have the same functions Table 4 2 describes the functions of them CloudEngine 7800 6800 5800 Series Switches Hardware Description 4 Fan Module Issue 16 2015 08 26 Huawei Proprietary ...

Страница 152: ... front to back airflow Panel Figure 4 3 and Figure 4 4 show the panels of the FAN 40EA series fan modules Figure 4 3 Panel of a FAN 40EA B fan module STATUS FAN 40EA B 2 3 1 4 5 Figure 4 4 Panel of a FAN 40EA F fan module STATUS FAN 40EA F 2 3 4 5 1 1 Captive screw 2 Airflow flag l back to front airflow l front to back airflow 3 Indicator CloudEngine 7800 6800 5800 Series Switches Hardware Descrip...

Страница 153: ...dingly Common causes of this alarm include errors of dual in line package DIP switches short circuits fan blades blocked and fault of the fan module Specifications Table 4 4 describes the technical specifications of the FAN 40EA series fan modules Table 4 4 Technical specifications of the FAN 40EA fan modules Item FAN 40EA B FAN 40EA F Dimensions W x D x H 94 5 mm x 183 1 mm x 39 8 mm Number of fa...

Страница 154: ...ed NOTE This fan module is supported in V100R002C00 version and later versions CE5850 48T4S2Q EI CE5850 48T4S2Q HI CE6850 48S4Q EI CE6850 48T4Q EI CE6810 48S4Q EI CE6850 48S6Q HI CE6851 48S6Q HI CE6810 48S4Q LI CE6810 48S LI CE7850 32Q EI CE6850U 48S6Q HI CE6850 48T6Q HI CE6850U 24S2Q HI CE6810 32T16S4Q LI CE6810 24S2Q LI CE5855 48T4S2Q EI CE5855 24T4S2Q EI Not supported Not supported Appearance F...

Страница 155: ...tions of a FAN 40SB fan module Function Description Automatic fan speed adjustment After the fan module communicates normally with the switch the switch controls the speed of fans based on temperature of the chassis Hot swap Supported Heat dissipation l FAN 40SB B back to front airflow l FAN 40SB F front to back airflow Panel Figure 4 7 and Figure 4 8 show the panels of the FAN 40SB fan modules Cl...

Страница 156: ... screw 2 Airflow flag l back to front airflow l front to back airflow 3 Indicator 4 Handle 5 Fan air vent Table 4 7 describes the indicator on the panels of the FAN 40SB fan modules CloudEngine 7800 6800 5800 Series Switches Hardware Description 4 Fan Module Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 146 ...

Страница 157: ...line package DIP switches short circuits fan blades blocked and fault of the fan module Specifications Table 4 8 describes the technical specifications of the FAN 40SB fan modules Table 4 8 Technical specifications of the FAN 40SB fan modules Item FAN 40SB B FAN 40SB F Dimensions W x D x H 94 5 mm x 183 1 mm x 39 8 mm Number of fans 1 Weight 0 3 kg Maximum power consumption 4 3 W Maximum fan speed...

Страница 158: ... EI CE6810 48S4Q LI CE6810 48S LI CE6850U 48S6Q HI CE6850 48T6Q HI CE6850U 24S2Q HI CE6851 48S6Q HI CE6810 32T16S4Q LI CE6810 24S2Q LI CE5855 48T4S2Q EI CE5855 24T4S2Q EI Not supported Not supported CE7850 32Q EI Supported NOTE This fan module is supported in V100R003C00 version and later versions Supported NOTE This fan module is supported in V100R003C00 version and later versions Appearance Figu...

Страница 159: ...e 4 10 Functions of a FAN 40HA fan module Function Description Automatic fan speed adjustment After the fan module communicates normally with the switch the switch controls the speed of fans based on temperature of the chassis Hot swap Supported Heat dissipation l FAN 40HA B back to front airflow l FAN 40HA F front to back airflow Panel Figure 4 11 and Figure 4 12 show the panels of the FAN 40HA f...

Страница 160: ... screw 2 Airflow flag l back to front airflow l front to back airflow 3 Indicator 4 Handle 5 Fan air vent Table 4 11 describes the indicator on the panels of the FAN 40HA fan modules CloudEngine 7800 6800 5800 Series Switches Hardware Description 4 Fan Module Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 150 ...

Страница 161: ...able 4 12 describes the technical specifications of the FAN 40HA fan modules Table 4 12 Technical specifications of the FAN 40HA fan modules Item FAN 40HA B FAN 40HA F Dimensions W x D x H 94 5 mm x 183 1 mm x 39 8 mm Number of fans 2 Weight 0 415 kg Maximum power consumption 40 W Maximum fan speed 19000 10 revolutions per minute RPM Maximum wind rate 64 cubic feet per minute CFM Part Number 02359...

Страница 162: ...HI CE6850U 24S2Q HI CE7850 32Q EI Not supported Not supported CE5855 48T4S2Q EI CE5855 24T4S2Q EI Supported NOTE This fan module is supported in V100R005C10 version and later versions Supported NOTE This fan module is supported in V100R005C10 version and later versions Appearance Figure 4 13 shows the appearance of a FAN 040A B fan module and Figure 4 14 shows the appearance of a FAN 040A F fan mo...

Страница 163: ...ions of a FAN 040A fan module Function Description Automatic fan speed adjustment After the fan module communicates normally with the switch the switch controls the speed of fans based on temperature of the chassis Hot swap Supported Heat dissipation l FAN 040A B back to front airflow l FAN 040A F front to back airflow Panel Figure 4 15 and Figure 4 16 show the panels of the FAN 040A series fan mo...

Страница 164: ... screw 2 Airflow flag l back to front airflow l front to back airflow 3 Indicator 4 Handle 5 Fan air vent Table 4 15 describes the indicator on the panels of the FAN 040A fan modules CloudEngine 7800 6800 5800 Series Switches Hardware Description 4 Fan Module Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 154 ...

Страница 165: ...e 4 16 describes the technical specifications of the FAN 040A series fan modules Table 4 16 Technical specifications of the FAN 040A fan modules Item FAN 040A B FAN 040A F Dimensions W x D x H 94 5 mm x 183 1 mm x 39 8 mm Number of fans 2 Weight 0 259 kg Maximum power consumption 12 W Maximum fan speed 16000 10 revolutions per minute RPM Maximum wind rate 40 cubic feet per minute CFM Part Number 0...

Страница 166: ...fan module is supported in V100R005C00 and later versions Supported NOTE The fan module is supported in V100R005C00 and later versions CE6850U 48S6Q HI CE6850 48T6Q HI CE6850U 24S2Q HI Supported NOTE The fan module is supported in V100R005C10 and later versions Supported NOTE The fan module is supported in V100R005C10 and later versions Appearance Figure 4 17 shows the appearance of a FAN 060A B f...

Страница 167: ...4 18 Functions of a FAN 060A fan module Function Description Automatic fan speed adjustment After the fan module communicates normally with the switch the switch controls the speed of fans based on temperature of the chassis Hot swap Supported Heat dissipation l FAN 060A B back to front airflow l FAN 060A F front to back airflow Panel Figure 4 19 and Figure 4 20 show the panels of FAN 060A series ...

Страница 168: ...5 1 Lock 2 Indicator 3 Fan air vent 4 Handle 5 Airflow flag l back to front airflow l front to back airflow Table 4 19 describes the indicator on a FAN 060A fan module CloudEngine 7800 6800 5800 Series Switches Hardware Description 4 Fan Module Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 158 ...

Страница 169: ...causes of this alarm include short circuits fan blades blocked and fault of the fan module Specifications Table 4 20 describes the technical specifications of the FAN 060A series fan modules Table 4 20 Technical specifications of FAN 060A series fan modules Item FAN 060A B FAN 060A F Dimensions W x D x H 86 0 mm x 198 3 mm x 40 0 mm Number of fans 2 Weight 0 478 kg Maximum power consumption 40 W M...

Страница 170: ...e DC Power Cable 5 4 Ground Cable 5 5 Console Cable 5 6 Network Cable 5 7 Optical Fiber 5 8 AOC Cable 5 9 Copper Cable CloudEngine 7800 6800 5800 Series Switches Hardware Description 5 Cables Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 160 ...

Страница 171: ...male to C14 straight male AC power cable Appearance and Structure Figure 5 1 shows the appearance of a C13 straight female to PI straight male AC power cable Figure 5 1 Appearance of a C13 straight female to PI straight male AC power cable C13 straight female connector PI straight male connector Figure 5 2 shows the appearance of a C13 straight female to C14 straight male AC power cable CloudEngin...

Страница 172: ...as follows l The C13 straight female connector is connected to the power socket of the 600 W AC 240 V DC power module l The C14 straight male connector is connected to a high voltage DC PDU If a high voltage DC power distribution box is used make OT or cord end terminals for the cable Cut the C14 straight male connector off and crimp OT or cord end terminals on the bare wires Connect the blue wire...

Страница 173: ...r cable X1 X2 X3 Length Conductor Cross Sectional Area 2 female Cord end terminal 4 2 grey Cord end terminal 4 2 grey 3 m 3 332 mm2 12AWG Connection A DC power cable connects to the DC power module of the device l X1 connector connects to the input port on the DC power module CloudEngine 7800 6800 5800 Series Switches Hardware Description 5 Cables Issue 16 2015 08 26 Huawei Proprietary and Confide...

Страница 174: ...h voltage DC straight female connector is connected to the power socket of the 600 W high voltage DC power module l The bare wires are connected to a 380 V high voltage DC power distribution frame or power distribution box Crimp OT or cord end terminals on the bare wires and then connect the blue wire to a negative terminal the brown wire to a positive terminal and the yellow green wire to a prote...

Страница 175: ...structure of a ground cable Figure 5 7 Structure of a ground cable 1m 4m Pin Assignments Table 5 2 lists the pin assignments of a ground cable CloudEngine 7800 6800 5800 Series Switches Hardware Description 5 Cables Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 165 ...

Страница 176: ...interference A ground cable is connected to a chassis in the following way l The OT6 4 naked crimping connector connects to the ground point on the chassis l The OT6 6 naked crimping connector connects to the ground point on the cabinet 5 5 Console Cable Appearance and Structure Figure 5 8 shows the appearance of a console cable Figure 5 8 Appearance of a console cable Figure 5 9 shows the structu...

Страница 177: ... console cable connects a device and a console as follows l The 8 pin RJ45 connector is connected to the console port of the device l The DB 9 female connector is connected to a maintenance terminal such as a computer 5 6 Network Cable Types of Network Cables Network cables are classified into straight through cables and crossover cables l Straight through cable The pin assignments of RJ45 connect...

Страница 178: ...nd a crossover cable have the same appearance Figure 5 10 and Figure 5 11 show the appearance of a network cable Figure 5 10 Appearance of a network cable 1 Figure 5 11 Appearance of a network cable 2 CloudEngine 7800 6800 5800 Series Switches Hardware Description 5 Cables Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 168 ...

Страница 179: ...range 1 2 Orange 2 3 White and green 3 4 Blue 4 5 White and blue 5 6 Green 6 7 White and brown 7 8 Brown 8 Table 5 5 lists the pin assignments of a crossover cable Table 5 5 Pin assignments of a crossover cable X1 Pin Wire Color X2 Pin 1 White and orange 3 2 Orange 6 3 White and green 1 4 Blue 4 CloudEngine 7800 6800 5800 Series Switches Hardware Description 5 Cables Issue 16 2015 08 26 Huawei Pro...

Страница 180: ...5 6 describes the supported cabling types for a 10GBASE T Ethernet electrical port Table 5 6 Supported cabling types for 10GBASE T Item Category 7 STP Category 6A STP Category 6A UTP Category 6 STP Category 6 UTP Cable Description Category 7 shielded twisted pair STP Category 6A shielded twisted pair Category 6A unshielded twisted pair UTP Category 6 shielded twisted pair Category 6 unshielded twi...

Страница 181: ...hese rules route these cables l Separate these cables with other types of cables If they must be routed in the same cable trough with other types of cables separated them from other cables using a metal plate l Separate cables as much as possible at the outlet and keep the cables parallel with each other Most alien crosstalk appears within 20 m away from the outlet To reduce alien crosstalk do not...

Страница 182: ...single mode fiber Single fiber push on LC connectors at both ends MPO MPO fiber multi fiber push on MPO connectors at both ends MPO 4 DLC fiber MPO connector at one end and four pairs of double LC DLC connectors at the other end MPO 8 FC fiber MPO connector at one end and eight FC connectors at the other end Appearance and Structure Figure 5 14 shows the appearance of an LC single mode fiber Cloud...

Страница 183: ...LC multi mode fiber Figure 5 15 Appearance of an LC multi mode fiber Figure 5 16 shows the appearance of an MPO MPO fiber CloudEngine 7800 6800 5800 Series Switches Hardware Description 5 Cables Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 173 ...

Страница 184: ... 5 17 Appearance of an MPO 4 DLC fiber Figure 5 18 shows the appearance of an MPO 8 FC fiber Figure 5 18 Appearance of an MPO 8 FC fiber CloudEngine 7800 6800 5800 Series Switches Hardware Description 5 Cables Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 174 ...

Страница 185: ...fiber X2 X1 1 2 3 4 5 6 7 8 9 10 11 12 12 11 10 9 8 7 6 5 4 3 2 1 Figure 5 20 shows the structure of an MPO 4 DLC fiber CloudEngine 7800 6800 5800 Series Switches Hardware Description 5 Cables Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 175 ...

Страница 186: ...5 6 7 8 9 10 11 12 1B 1A 2B 2A 4B 4A Figure 5 21 shows the structure of an MPO 8 FC fiber CloudEngine 7800 6800 5800 Series Switches Hardware Description 5 Cables Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 176 ...

Страница 187: ...fiber Table 5 8 Pin assignments of an MPO MPO fiber X1 Pin X2 Pin 1 1 2 2 3 3 4 4 9 9 10 10 11 11 12 12 MPO 4 DLC and MPO 8 FC fibers have the same pin assignments as shown in Table 5 9 CloudEngine 7800 6800 5800 Series Switches Hardware Description 5 Cables Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 177 ...

Страница 188: ...800 5800 series switches for stacking or service aggregation l Scenario 2 used for connection between 10GE or 40GE ports of CE7800 6800 5800 series switches and CE12800 Each end connects to a 10GE port using an SFP optical module Each end connects to a 40GE port using an QSFP optical module MPO MPO fiber l Scenario 1 used for connection between two CE7800 6800 5800 series switches for stacking or ...

Страница 189: ...ODF The MPO connector connects to the switch using a QSFP optical module and the eight FC connectors connect to the ODF 5 8 AOC Cable Types of AOC Cables An active optical cable AOC is an active optical fiber with optical modules at both ends and therefore is easy to use Figure 5 22 and Figure 5 23 show different types of AOC cables Figure 5 22 Appearance of an SFP to SFP AOC cable Figure 5 23 App...

Страница 190: ...d cable connections in these scenarios Table 5 12 AOC cable usage scenarios and connections Cable Type Connection SFP to SFP AOC cable l Scenario 1 used for 10GE optical port connection or stacking between CE7800 6800 5800 series switches l Scenarios 2 used for 10GE connection between CE12800 and CE7800 6800 5800 switches Both ends connect to a 10GE optical port QSFP to QSFP AOC cable l Scenario 1...

Страница 191: ... SFP 02310MUQ QSFP 40G CU1M 1 m Passiv e QSFP to QSFP 02310MUG QSFP 40G CU3M 3 m Passiv e QSFP to QSFP 02310MUH QSFP 40G CU5M 5 m Passiv e QSFP to QSFP 02310MUJ QSFP 4SFP10G CU1M 1 m Passiv e QSFP to 4 SFP 02310MUK QSFP 4SFP10G CU3M 3 m Passiv e QSFP to 4 SFP 02310MUL QSFP 4SFP10G CU5M 5 m Passiv e QSFP to 4 SFP 02310MUM Appearance and Structure Figure 5 24 shows the appearance of an SFP to SFP co...

Страница 192: ...pper cable Figure 5 26 shows the appearance of a QSFP to 4 SFP copper cable Figure 5 26 Appearance of a QSFP to 4 SFP copper cable Figure 5 27 shows the structure of an SFP to SFP copper cable CloudEngine 7800 6800 5800 Series Switches Hardware Description 5 Cables Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 182 ...

Страница 193: ...re 5 29 shows the structure of a QSFP to 4 SFP copper cable Figure 5 29 Structure of a QSFP to 4 SFP copper cable X1 X2 A B D C Connection Table 5 14 describes usage scenarios of copper cables and cable connections in these scenarios CloudEngine 7800 6800 5800 Series Switches Hardware Description 5 Cables Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd ...

Страница 194: ...hes l Scenario 2 used to set up a stack of CE7800 6800 5800 series switches using 40GE optical ports Each end connects to a 40GE optical port l Minimum clearance for cable routing 75 mm l Minimum bend radius 50 mm QSFP to 4 SFP copper cable When a 40GE optical port is configured as four 10GE optical ports one end of this cable connects to a 40GE optical port and the other end connects to four 10GE...

Страница 195: ...d for Huawei switches Non certified optical modules cannot ensure transmission reliability and may affect service stability on the switch Huawei is not responsible for any problem caused by non certified optical modules and will not fix such problems l All the optical modules listed in the documentation are Huawei certified optical modules 6 1 Concepts 6 2 SFP SFP Modules 6 3 QSFP Modules CloudEng...

Страница 196: ...s sent from different types of sources can transmit over different distances due to negative effects of optical fibers such as dispersion and attenuation Interface rate Maximum rate of electrical signals that an optical device can transmit without bit errors Various interface rates are defined in Ethernet standards such as 125 Mbit s 1 25 Gbit s 10 3125 Gbit s and 41 25 Gbit s CloudEngine 7800 680...

Страница 197: ...s Modal bandwidth Bandwidth measured at a point with transmit power several dB lower than that of the point with the peak center wavelength Modal bandwidth reflects spectrum characteristics of an optical module Fiber diameter Diameter of the core of a fiber According to international standards for optical fibers the diameter of a multi mode fiber is 62 5 um or 50 um and the diameter of a single mo...

Страница 198: ...hout signals transmitted in complete modulation mode The extinction ratio indicates the capability of an optical module to identify signal 0 and signal 1 6 2 SFP SFP Modules Appearance Figure 6 2 shows an SFP SFP module Figure 6 2 Appearance of an SFP SFP module Figure 6 3 shows a GE copper module CloudEngine 7800 6800 5800 Series Switches Hardware Description 6 Optical Module Issue 16 2015 08 26 ...

Страница 199: ...mperat ure 02318 169 OMX D3000 0 Suppor ted in V100R 001C0 0 and later versio ns 26 m 10GBA SE SR Multi mode 160 62 5 LC 0 C to 70 C 33 m Multi mode OM1 200 62 5 LC 66 m Multi mode 400 50 LC 82 m Multi mode OM2 500 50 LC 300 m Multi mode OM3 2000 50 LC 400 m Multi mode OM4 4700 50 LC 02310 CRM OSXD 22N00 220 m 10GBA SE LRM Multi mode 160 500 62 5 LC CloudEngine 7800 6800 5800 Series Switches Hardw...

Страница 200: ...0N01 40 km 10GBA SE ER Single mode G 652 9 LC 02310 SNN SFP 1 0G ZR 80 km 10GBA SE ZR Single mode G 652 9 LC 02310J FE LE2M XSC8 0FF0 Suppor ted only in V100R 001C0 0 and V100R 002C0 0 80 km 10GBA SE ZR Single mode G 652 9 LC 02310 MNW SFP 1 0G USR Suppor ted in V100R 002C0 0 and later versio ns 30 m 10GBA SE USR Multi mode OM2 500 50 LC 100 m Multi mode OM3 2000 50 LC 150 m Multi mode OM4 4700 50...

Страница 201: ... in V100R 005C0 0 and later versio ns 40 km 10GBA SE BDER Single mode G 652 9 LC 02311 BJC SFP 1 0G ER SM12 70 BIDI Single fiber bidirec tional optical modul e 02311 BJJ SFP 1 0G iLR Suppor ted in V100R 005C0 0 and later versio ns 1 4 km 10GBA SE iLR Single mode G 652 9 LC CloudEngine 7800 6800 5800 Series Switches Hardware Description 6 Optical Module Issue 16 2015 08 26 Huawei Proprietary and Co...

Страница 202: ...4 7 to 4 14 1 1 3 SFP 10G ZR 1550 0 to 4 24 7 9 LE2MXS C80FF0 1550 0 to 4 24 7 9 SFP 10G USR 850 7 3 to 1 10 7 0 5 3 SFP 10G ER SM1330 BIDI Single fiber bidirectio nal optical module Tx1330 Rx1270 0 to 5 18 9 3 5 SFP 10G ER SM1270 BIDI Single fiber bidirectio nal optical module Tx1270 Rx1330 SFP 10G iLR 1310 8 2 to 0 5 14 4 0 5 3 5 CloudEngine 7800 6800 5800 Series Switches Hardware Description 6 ...

Страница 203: ...ission distance 70 km Fiber mode connector type single mode LC Standard CWDM Operating temperature 0 C to 70 C l Transmit power 0 dBm to 4 dBm l Receiver sensitivity 23 dBm l Overload optical power 7 dBm l Extinction ratio 8 2 dB GE Optical Module Table 6 4 and Table 6 5 list the attributes of GE optical modules Table 6 4 Attributes of GE optical modules Part Num ber Mode l Versi on Supp ort Trans...

Страница 204: ...550 m 1000BA SE LX10 Multi mode OM1 200 500 62 5 LC 550 m Multi mode 400 400 50 LC 550 m Multi mode OM2 500 500 50 LC 10 km Single mode G 652 9 LC 02317 346 S SFP GE LH40 SM13 10 40 km 1000BA SE EX Single mode G 652 9 LC 02317 348 S SFP GE LH80 SM15 50 80 km 1000BA SE ZX Single mode G 652 9 LC 02315 206 eSFP GE ZX100 SM15 50 100 km Single mode LC CloudEngine 7800 6800 5800 Series Switches Hardware...

Страница 205: ...A SE BX10 D 1000BA SE BX10 U Single mode G 652 9 LC 02315 286 SFP GE LX SM14 90 BIDI Single fiber bidirec tional optical modul e 02310 KVU LE2M GSC4 0ED0 Single fiber bidirec tional optical modul e Suppor ted in V100R 002C0 0 and later versio ns 40 km Single mode G 652 LC CloudEngine 7800 6800 5800 Series Switches Hardware Description 6 Optical Module Issue 16 2015 08 26 Huawei Proprietary and Con...

Страница 206: ...X SM1490 BIDI Table 6 5 Optical parameters of GE optical modules Model Operating Wavelength nm Transmit Optical Power dBm Receiver Sensitivity dBm Overload Optical Power dBm Extinction Ratio dB eSFP GE SX MM850 850 9 5 to 2 5 17 0 9 SFP GE LX SM1310 1310 9 to 3 20 3 9 S SFP GE LH40 SM1310 1310 5 to 0 23 3 9 S SFP GE LH80 SM1550 1550 2 to 5 23 3 9 eSFP GE ZX100 SM1550 1550 0 to 5 30 9 8 CloudEngine...

Страница 207: ... bidirectio nal optical module Tx1490 Rx1310 LE2MGS C40ED0 Single fiber bidirectio nal optical module Tx1490 Rx1310 2 to 3 23 3 9 LE2MGS C40DE0 Single fiber bidirectio nal optical module Tx1310 Rx1490 GE CWDM Optical Module Table 6 6 lists the attributes of GE CWDM optical modules CloudEngine 7800 6800 5800 Series Switches Hardware Description 6 Optical Module Issue 16 2015 08 26 Huawei Proprietar...

Страница 208: ... type single mode LC Standard CWDM Operating temperature 0 C to 70 C l Transmit power 0 dBm to 5 dBm l Receiver sensitivity 28 dBm l Overload optical power 9 dBm l Extinction ratio 8 5 dB GE Copper Module Table 6 7 lists the attributes of GE copper modules Table 6 7 Attributes of GE copper modules Part Num ber Mode l Versi on Supp ort Transmissi on Distance Standard Cable Type Connec tor Type 0231...

Страница 209: ...ater versions 2 km 100BA SE FX Multi mode OM1 200 62 5 LC 0 C to 70 C Multi mode 400 50 LC Multi mode OM2 500 50 LC 0231520 5 eSFP FE LX SM1310 15 km 100BA SE LX Single mode G 652 9 LC 0231734 4 S SFP FE LH40 SM1310 40 km 100BA SE EX Single mode G 652 9 LC 0231520 3 SFP FE LX SM1310 BIDI Single fiber bidirectio nal optical module 15 km 100BA SE BX Single mode G 652 9 LC CloudEngine 7800 6800 5800 ...

Страница 210: ... be used with SFP FE LX SM1550 BIDI Table 6 9 Optical parameters of 100M optical modules Model Operating Wavelength nm Transmit Optical Power dBm Receiver Sensitivity dBm Overload Optical Power dBm Extinction Ratio dB SFP FE SX MM1310 1310 19 to 14 30 14 10 eSFP FE LX SM1310 1310 15 to 8 31 8 8 2 S SFP FE LH40 SM1310 1310 5 to 0 37 10 10 5 CloudEngine 7800 6800 5800 Series Switches Hardware Descri...

Страница 211: ...butes and optical parameters of an FC optical module Table 6 10 Attributes of an FC optical module Part Number Model Version Support Rate Trans missi on Dista nce Fiber Mode Modal Bandwidth MHz km Core Diameter μm Connector Type Operating Temperatur e 02311BJ H SFP FC2G SW SR Supported in V100R00 5C10 and later versions 2GE 0 3 km Multi mode OM2 500 50 LC 20 C to 85 C 0 5 km Multi mode OM3 2000 50...

Страница 212: ... km Single mode G 652 9 LC 0 C to 70 C 02311BJL SFP FC8G SW SR 8GE 0 05 km Multi mode OM2 500 50 LC 0 C to 70 C 0 15 km Multi mode OM3 2000 50 LC 4GE 0 15 km Multi mode OM2 500 50 LC 0 38 km Multi mode OM3 2000 50 LC 2GE 0 3 km Multi mode OM2 500 50 LC 0 5 km Multi mode OM3 2000 50 LC 02311BJ A SFP FC8G LW LR 2GE 4GE 8GE 10 km Single mode G 652 9 LC 0 C to 70 C CloudEngine 7800 6800 5800 Series Sw...

Страница 213: ...W LR 1310 5 to 0 21 0 8 2 SFP FC4G SW SR 850 9 to 1 5 15 0 3 SFP FC4G LW LR 1310 8 4 to 1 18 0 9 SFP FC8G SW SR 850 8 2 to 1 3 11 2 0 9 SFP FC8G LW LR 1310 8 4 to 0 5 13 8 0 5 3 5 6 3 QSFP Modules Appearance Figure 6 4 shows the appearance of a QSFP module CloudEngine 7800 6800 5800 Series Switches Hardware Description 6 Optical Module Issue 16 2015 08 26 Huawei Proprietary and Confidential Copyri...

Страница 214: ...0R 001C0 0 and later version s 30 m 40GBase SR4 10GBase USR four lanes Multi mode OM2 500 50 MPO 0 C to 70 C 100 m Multi mode OM3 2000 50 MPO 150 m Multi mode OM4 4700 50 MPO 02310 MHS QSFP 40G LR4 10 km 40GBase LR4 Single mode G 652 9 LC 02310 RMB QSFP 40G eSR4 Suppor ted in V100R 003C0 0 and later 82 m 40GBase eSR4 10GBase SR four lanes Multi mode OM2 500 50 MPO 300 m Multi mode OM3 2000 50 MPO ...

Страница 215: ...2 9 MPO Table 6 13 Optical parameters of 40GE optical modules Model Center Wavelen gth nm Transmit Optical Power dBm Receiver Sensitivity dBm Overload Optical Power dBm Extinction Ratio dB QSFP 40 G iSR4 850 7 6 to 1 9 5 2 4 3 QSFP 40 G LR4 1271 1291 1311 1331 7 to 2 3 11 5 3 3 3 5 QSFP 40 G eSR4 850 7 6 to 1 5 4 2 4 3 QSFP 40 G ER4 1271 1291 1311 1331 2 7 to 4 5 19 5 4 5 5 5 QSFP 40 G iSM4 1310 8...

Отзывы: