background image

 

 

 

 

 

AP4130DN

 

Quick Start Guide

 

FCC ID: QISAP4030DN

 

 

Issue 01

 

Date 2015-02-06

 

HUAWEI TECHNOLOGY CO., LTD

 

Содержание AP4130DN

Страница 1: ...AP4130DN Quick Start Guide FCC ID QISAP4030DN Issue 01 Date 2015 02 06 HUAWEI TECHNOLOGY CO LTD ...

Страница 2: ...e customer All or part of the products services and features described in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject...

Страница 3: ...is document are defined as follows Symbol Description Indicates an imminently hazardous situation which if not avoided will result in death or serious injury Indicates a potentially hazardous situation which if not avoided could result in death or serious injury Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury Indicates a potentially hazardous...

Страница 4: ...escription NOTE is used to address information not related to personal injury equipment damage and environment deterioration Change History Changes between document issues are cumulative The latest document issue contains all changes made in previous issues Issue 01 2014 11 07 Initial commercial release ...

Страница 5: ...ion 11 2 1 Preparing for Installation 11 2 2 Unpacking the Equipment 12 2 3 Determining the Installation Position 13 2 4 Installing the AP 14 2 4 1 Wall Mounting 14 2 4 2 Ceiling Mounting 15 2 4 3 T rail Mounting 16 2 5 Installing the Security Lock 17 2 6 Connecting Cables 18 2 7 Powering on the AP 19 3 Logging In to the AP 20 3 1 Logging In to the AP Through the Console Port 20 3 2 Logging In to ...

Страница 6: ... time management and maintenance Huawei indoor APs are especially applicable to places with simple building structure small size dense users and high capacity demands such as small size conference rooms bars and leisure centers They can be flexibly deployed according to surrounding environment 1 1 Device Structure 1 2 Indicator Description 1 3 Basic Specifications 1 1 Device Structure Figure in Fi...

Страница 7: ... power adapter The AP supports the PoE power supply and DC power supply To connect the AP to a DC power source use the power adapter delivered with the AP otherwise the AP maybe damaged 4 Security slot Fasten the cable of the security lock to an immovable object around and insert the security lock into the security slot and lock it 1 2 Indicator Description The following information describes indi...

Страница 8: ...and starts uploading the software the indicator blinks green once Until the software is uploaded and started the indicator remains steady green Running status Green Blinking once every 2s 0 5 Hz The system is running properly the Ethernet connection is normal and STAs are associated with the AP The system enters the Uboot CLI Blinking once every 5s 0 2 Hz The system is running properly the Etherne...

Страница 9: ...le in Table 1 3 shows the specifications of AP4130DN Table 1 3 Basic specifications of the AP4130DN Item Description Technical specifications Dimensions H x W x D 180mm 180mm 54 5mm not include mounting bracket Weight 0 4kg not include mounting bracket System memory 256MB DDR2 32 MB Flash Power specifications Power input 12V 10 2A Maximum power consumption 10 2W PoE 48V DC 0 35A Environment specif...

Страница 10: ...O O O O O O O 表示该有毒有害物质在该部件所有均质材料中的含量在 SJ T11363 2006 标准规定的限量要求下 Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is below the relevant threshold of the SJ T11363 2006 standard X 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ T11363 2006 标准规定的限量要求 Indicates that the concentration of the hazardous substance of at least one of all homogeneous materials in the pa...

Страница 11: ...sition away from any liquid and prevent the device from slipping Keep the device clean Do not put the device and tools in the aisles This device uses non harmonized frequency and is intended for use in all European countries The WLAN can be operated in the EU without restriction indoors but cannot be operated outdoors A 20cm separation distance needs to be maintained to ensure compliance with the ...

Страница 12: ...45 crimping tool Wire stripper Network cable tester Multimeter Level 2 2 Unpacking the Equipment Before unpacking the carton ensure that the packing carton is intact and not damaged or soaked Stop unpacking if the equipment is rusted or soggy Then investigate causes and contact the supplier Usually the packing list contains the following items AP Mounting Bracket Power adapter optional Quick Start...

Страница 13: ... AP in a hidden position that does not affect daily lives and work of residents Install the AP in a site that is free from leaking or dripping water heavy dew and humidity and take protective measures to prevent water from flowing into the equipment along the cable Indoor APs are usually mounted on a wall or ceiling using sheet metal mounting brackets The installation position is determined by the...

Страница 14: ...nting 1 Fix the mounting bracket to the wall adjust the installation position and use the marker to mark the drilling positions where expansion screws are installed 2 Use a 6 mm drill bit to drill 25 mm to 30 mm deep holes in the drilling positions Hammer the expansion tubes into the holes until the expansion tubes are completely embedded into the wall ...

Страница 15: ...cket to the wall and use the Phillips screwdriver to fasten three expansion screws into the expansion 3 Align the mounting screws at the rear of the AP with the mounting holes on the mounting bracket and hang the AP on the bracket Press the AP downwards to secure the AP on the wall 2 4 2 Ceiling Mounting ...

Страница 16: ...The screws provided for ceiling mounting of APs are 30 mm long and can be used to fix an AP on a ceiling not thicker than 15 mm To install APs on thicker ceilings you need to purchase longer screws Ensure that the AP is correctly installed on the mounting bracket and there must be 200 mm space above and around the AP for maintenance 2 4 3 T rail Mounting 1 Remove two ceiling tiles around the T rai...

Страница 17: ...e the AP 1 Before fixing the adjustable buckle with a screw you need to adjust the buckle to a proper position based on the T rail width 2 Ensure that the AP is correctly installed on the mounting bracket and there must be 200 mm space above and around the AP for maintenance 2 5 Installing the Security Lock There is a security slot on the AP You can lock the AP to an immovable object to prevent th...

Страница 18: ...e category 5 enhanced or higher twisted pairs Ensure that the AP is connected to the Ethernet using the Ethernet cable that works properly If the Ethernet cable is not working properly for example RJ45 connectors are short circuited the AP may fail to be powered on or fail to work Before connecting an Ethernet cable to the AP use the cable test tool to check whether the cable is qualified If the c...

Страница 19: ... If the cable is unqualified replace it Do not connect the service network cable to the console port Otherwise the AP may be damaged when the PoE power supply is used Before removing network cables or power cables remove the AP from the mounting bracket first to prevent damage to the network cables or power cables The cable cannot exceed 100 meters 2 7 Powering on the AP You can check the power on...

Страница 20: ...rt of the AP and the DB9 connector to the serial port of a PC Step 2 Run the terminal emulation program on the PC For example to open the HyperTerminal of Windows XP on the PC choose Start Programs Accessories Communications HyperTerminal Enter a connection name and click OK Step 3 Select the serial port used on the PC and click OK Step 4 Set communication parameters click Restore Defaults and the...

Страница 21: ...ss and subnet mask The IP address must be on the network segment 169 254 0 0 16 but cannot be 169 254 1 1 169 254 1 100 is recommended The subnet mask is 255 255 0 0 Before the device is delivered the STelnet service has been configured on the device The STelnet interface number is 22 and the default user name and password are respectively admin and admin huawei com Use the SSH client software to ...

Страница 22: ...ation page Step 3 Click Open Enter the user name and password at the prompt and press Enter You have logged in to the device The following information is only for reference login as admin Sent username admin admin 169 254 1 1 s password Huawei It is recommended that you change the initial user name and password after login ...

Страница 23: ...ment system and connect the PC to the GE interface Start the web browser on the PC and visit http 169 254 1 1 to log in to the web management system You can only log in to the FAT AP using the web platform Procedure Step 1 Open a web browser on a PC and enter the management address in the format of http 169 254 1 1 in the address bar Ensure that the PC and AC can communicate with each other Then p...

Страница 24: ...AP4130DN Quick Start Guide 4 Caution Issue 01 2015 02 06 华为专有和保密信息 版权所有 华为技术有限公司 24 4 Caution 4 1 Caution ...