Figure 3-2
Procedure for commissioning the base station that starts to provide services of one
mode
1.
Configure the transmission data of the MBTS in mode A. The transmission data includes
but is not limited to E1, MP link, MP group, IP address, routing information, DHCP (used
at the MBTS in mode B) relay information, and VLAN.
(1) Configure the transmission data and export the data configuration file using the CME.
For details, see the
GBTS Initial Configuration Guide
,
NodeB Initial Configuration
Guide
, or
eNodeB Initial Configuration Guide
accordingly.
(2) Load the data configuration file to the base station in mode A. You are advised to load
the data configuration file locally using a USB disk. For details, see
Software and Configuring Data by Using the USB Disk
NOTE
You can configure other data of the base station in mode A after it is planned. The data configuration
of boards such as PMU and FUN in mode A must comply with mode B. Otherwise, alarm are reported
because of configuration conflict.
2.
Commission the MBTS in mode B by following the procedure for commissioning a single-
mode base station. For details, see the
GBTS Commissioning Guide
,
NodeB Commissioning
Guide
, or
eNodeB Commissioning Guide
accordingly.
3900 Series Multi-Mode Base Station
Commissioning Guide
3 Procedure for Commissioning the Base Station that Starts
to Provide Services of One Mode
Issue 02 (2010-07-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3-3