switch modules are not stacked, log in to each switch module and repeat the
preceding log collection procedure.)
[ftp]mkdir swi2
[ftp]cd swi2
[ftp]mput 2#flash:/logfile/*
[ftp]cd ..
[ftp]quit
221 Windows FTP Server (WFTPD, by Texas Imperial Software) says goodbye
<HUAWEI>
NO TE
– When you use the mput command in the FTP CLI, 2#flash:/ indicates the flash
root directory of the switch module with the stack ID 2. You can obtain the stack
ID and role information by using the display stack command.
– The flash root directory of the master switch module in a stack is flash:/.
– If multiple switch modules are displayed after running the display stack
command, obtain the log file of each switch module in the logfile directory.
4. View the log file in the FTP directory on the PC.
----End
4.4.2.5 Using the Web Tools Page of a Switch Module to Collect FC
Switching Plane Information (MX510)
Operation Scenario
Use Web Tools page of a switch module (MX510) to collect information about the
FC switching plane.
This section applies to the CX311, CX911, and CX915.
Prerequisites
Conditions
●
The connection between the management IP address of the FC switch module
and the server IP address is normal.
●
You have logged in to the Ethernet switching plane Web Tools page. For
8.10 Logging In to the Web Tools of the MX510
Data
Table 4-7 Data list
Parameter
Example Value
IP address
192.168.1.100
Subnet mask
255.255.255.0
Default gateway
0.0.0.0
Huawei Servers
Troubleshooting
4 Collecting Information
Issue 20 (2020-09-25)