No.
Parameter
Description
Remarks
23
Apparent power
baseline (kVA)
Adjust the apparent output
baseline of the inverter.
-
24
Active power
baseline (kW)
Adjusts the active output baseline
of the inverter.
-
25
Power percentage
for triggering Q-U
scheduling
Specifies the reference apparent
power, in percentage. When the
actual apparent power of the
inverter is greater than the value
of this parameter, the Q-U
characteristic curve scheduling
function is enabled.
-
26
Q-U characteristic
curve
The inverter adjusts Q/S (the ratio
of the output reactive power to
apparent power) in real time
based on U/Un(%) (the ratio of
the actual power grid voltage to
the rated power grid voltage).
-
27
Q-P characteristic
curve
The inverter adjusts Q/Pn (the
ratio of the output reactive power
to the rated active power) in real
time based on P/Pn(%) (the ratio
of the actual active power to the
rated active power).
-
28
Cosφ-P/Pn
characteristic curve
The inverter adjusts the output
power factor cosφ in real time
based on P/Pn(%).
-
7.2 Operations with a USB Flash Drive
USB flash drives of SanDisk, Netac, or Kingston are supported. Other USB flash
drives may not be identified because they are not tested for compatibility.
NO TE
Delete the script file immediately after use to reduce information disclosure risks.
7.2.1 Exporting Configurations
Procedure
1. Click Local maintenance script on the app to generate a boot script file, see
the
FusionSolar APP and SUN2000 APP User Manual
.
2. Import the boot script file to a PC.
(Optional) The boot script file can be opened as a .txt file.
SUN2000-(196KTL-H0, 200KTL-H2, 215KTL-H0)
Series
User Manual
7 Man-Machine Interactions
Issue 07 (2021-07-08)
Copyright © Huawei Technologies Co., Ltd.