background image

LONG HAND

IMPULSE SEALER

OPERATING INSTRUCTIONS

MODELS

FS-600H, FS-800H, FS-100H

TROUBLESHOOTING

MALFUNCTIONS

REASONS

SUGGESTIONS

No sealing

Power lamp is off

Disconnected plug

Power cord is broken

Transformer is broken

Check or change the plug

Replace or repair the cord

Replace the transformer

No sealing

Power lamp is on

Sealing lamp is on

Heater (heating element) is

broken

Spring hook our mounting

spring is loose or in poor
contact

Terminals of the heating

Replace the heater

Clean or tighten spring

hook connection

Clean the terminals and

adjust if needed

Terminals of the heating

element are in poor
contact

No sealing

Power lamp is on

Sealing lamp is off

Microswitch is activated

Defective microswitch

Adjust the microswitch

lever

Adjust the microswitch

position

Replace the microswitch

Teflon cloth burn

Timer malfunction

Prolonged heating time

Replace timer or relay

Decrease the timer
setting

Heating wire breaks

Worn Teflon adhesive

Replace the Teflon
adhesive

Seal is wrinkled

Heating timer is set too

high

Cooling time is not enough

Lower the timer setting

Continue pressing the

upper lever for 1-2

Cooling time is not enough

upper lever for 1-2
seconds after the light
goes off

Imperfect seal

Worn Teflon cloth

Worn silicone rubber

Replace Teflon cloth

Replace silicone rubber

Broken seal

Prolonged sealing time

Decrease timer setting

Non-full-weld seal

Sealing time is too short

Increase sealing time

Seal sticking

Dirty Teflon cloth

Dirty sealing bar

Clean the Teflon cover

Clean the silicone rubber
sealing bar

Отзывы: