PARAMETER CHECKING AND ADUSTMENT
Parameter list
Some
system
parameters can be checked and adjusted by the controller. Below is the parameter
list:
Parameter
No.
Description
Range
Default
Remarks
0
Tank water setting temp.
10 ~ 70°C
50°C
Adjustable
1
Water temperature gap
to restart
2 ~ 15°C
5°C
Adjustable
2
E-heater off tank water temp
10 ~ 85°C
55°C
Adjustable
3
E-heater delay time
0 ~ 90min
6
t * 5 min
4
Week disinfection temperature
50 ~ 70°C
70°C
Adjustable
5
High temp disinfection time
0 ~ 90 min
30 min
Adjustable
6
Defrosting period
30~90 min
45 min
Adjustable
7
Defrosting entry coil temp.
-30 ~ 0°C
-7°C
Adjustable
8
Defrosting exit coil temp.
2 ~ 30°C
13°C
Adjustable
9
Max defrosting cycle period
1 ~ 12 min
8 min
Adjustable
10
Electronic
expansion
valve
adjustment
0/1
1
Adjustable (0-manual
,
1-auto)
11
Target over-heat degree
-9 ~ 9°C
5°C
Adjustable
12
Steps of manually adjusting the
electronic expansion valve
10 ~ 50 step
35 step Adjustable
13
Disinfection
start
up
time
adjusting
0~23
23
Adjustable(hour)
14
Parameter of solar water pump
0/1
0
Adjustable( 0 without
water pump
,
1with water
pump)
15
Solar water pump star return
difference
2-20
℃
10
Adjustable
16
High
temp
disinfection
frequency
7-28day
7
Adjustable
A
Inlet
water
temp.
sensor
detect range
-9 ~ 99°C
Actual testing value. Error code P1
will be shown in case of a
malfunction
B
Outlet
water
temp.
sensor
detect range
-9 ~ 99°C
Actual testing value. Error code P2
will be shown in case of a
malfunction
C
Evaporator
coil
temp.
sensor detect range
-9 ~ 99°C
Actual testing value. Error code P3
will be shown in case of a