HTW IX41B Скачать руководство пользователя страница 8

 Unit Parts

 

 And Major 

Functions

Page 8 

Operating Conditions

Use the system under the following temperatures for safe and effective operation. If the air 

conditioner is used under different conditions, it may malfunction or become less efficient.

Features

Protection of the air conditioner

Compressor protection

The compressor cannot restart for 3 minutes

after it stops.

Anti-cold air (Cooling and heating models 

only)

The unit is designed not to blow cold air on

HEAT mode, when the indoor heat exchanger

is in one of the following three situations and

the set temperature has not been reached.

A) When heating has just started.

B) During defrosting.

C) Low temperature heating.

The indoor or outdoor fan stop running when

defrosting (Cooling and heating models only).

Defrosting (Cooling and heating models only)

Frost may be generated on the outdoor unit

during a heat cycle when outdoor temperature

is low and humidity is high resulting in lower

heating efficiency in the air conditioner.

Under these conditions, the air conditioner will

stop heating operations and start defrosting

automatically.

The time to defrost may vary from 4 to 10

minutes, depending the outdoor temperature

and the amount of frost buildup on the

outdoor unit.

 

Auto-Restart (some models)

In case of power failure, the system will 

immediately stop. When power returns, the 

Operation light on the indoor unit will flash. To 

restart the unit, press the 

ON/OFF 

button on the 

remote control. If the system has an auto restart 

function, the unit will restart using the same 

settings.     

White mist emerging from the indoor unit

A white mist may be generated due to a large

temperature difference between air inlet and

air outlet on COOL mode in places with high

relative humidity.

A white mist may be generated due to moisture

created in the defrosting process when the air

conditioner restarts in HEAT mode operation

after defrosting.

Noise coming from the air conditioner

You may hear a low hissing sound when the

compressor is running or has just stopped

running. This sound is the sound of the

refrigerant flowing or coming to a stop.

You may also hear a low "squeaking" sound

when the compressor is running or has just

stopped running. This is caused by tempera

heat expansion and cold contraction of the

plastic parts in the unit when the temperature

is changing.

A noise may be heard due to the louver

restoring itself to its original position when

power is first turned on.

Dust blowing out from the indoor unit.

This is happens when the air conditioner has not

been used for a long time or during its first use.

Smell emitting from the indoor unit.

This is caused by the indoor unit giving off smells

permeated from building materials, furniture,or 

smoke.

NOTE: 

For multi-split type air conditioners, one outdoor unit can be matched to different types of 

indoor units. All of the pictures in this manual are for demonstration purposes only. Your air 

conditioner may be slightly different, if similar in shape. The following pages introduce several kinds 

of indoor units that can be matched with the outdoor units.

COOL Mode

HEAT mode

DRY mode

Indoor 

Temperature 

17-32°C(62-90°F)

0-30°C (32-86°F)

17-32°C(62-90°F)

Outdoor 

Temperature 

0-50°C (32-122°F)

-15-24°C (5-75°F)

0-50°C (32-122°F)

-7-24°C (19-75°F)

0-60°C (32-140°F)

-15-50°C (5-122°F)

(For models with low-temp 

cooling systems) 

0-60°C (32-140°F)

(For special tropical models) 

Содержание IX41B

Страница 1: ...OWNER S MANUAL ENGLSIH Thanks for choossing our product Please read carefully this manual before using the product IX41B...

Страница 2: ...Unit Parts and Major Functions 06 Manual Operation and Maintenance 10 Table of Contents Owner s Manual SAFETY FIRST Safety Precautions 04 1 2 3...

Страница 3: ...rer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants For more details...

Страница 4: ...cess or to clean other than those recommended by the manufacturer The appliance shall be stored so as to prevent mechanical damage from occurring General Introduction Failure to observe a warning may...

Страница 5: ...he evaporator coils inside the indoor unit The evaporator coils are sharp and may cause injury DO NOT place items that might be affected by moisture damage under the indoor unit Condensation can occur...

Страница 6: ...r filter behind 5 Horizontal louver 6 LCD display window 7 Vertical louver 8 Manual control button behind 9 Remote controller holder Outdoor unit 10 Drain hose refrigerant connecting pipe 11 Connectiv...

Страница 7: ...Remote controller 4 Installation part 5 Display panel Outdoor unit 6 Drain hose refrigerant connecting pipe 7 Connective cable 8 Stop valve 9 Fan hood Fig 2 4 Indoor unit 1 Drain pump drain water from...

Страница 8: ...white mist may be generated due to a large temperature difference between air inlet and air outlet on COOL mode in places with high relative humidity A white mist may be generated due to moisture crea...

Страница 9: ...ure rises on COOL mode or falls on HEAT mode to the set point Droplets of water may form on the surface of the indoor unit when cooling occurs in relatively high humidity defined as higher than 80 Adj...

Страница 10: ...unit periodically Contact a local dealer or a customer service centre if the unit requires servicing When the air conditioner is to be used again Use a dry cloth to wipe off the dust accumulated on th...

Страница 11: ...Pre heating Defrost indicators are lit up the outdoor temperature is too cold and the unit s anti cold wind is activated in order to defrost the unit In Cooling only Models If the Fan Only indicator...

Страница 12: ...optimize product operation The indoor unit makes noises A squeaking sound is heard when the system is OFF or in COOL mode The noise is also heard when the drain pump optional is in operation A squeaki...

Страница 13: ...ll doors and windows are closed while operating the unit Excessive heat is generated by sunlight Close windows and curtains during periods of high heat or bright sunshine Low refrigerant due to leak o...

Страница 14: ...al waste When disposing of this appliance you have the following options Dispose of the appliance at designated municipal electronic waste collection facility When buying a new appliance the retailer...

Страница 15: ......

Страница 16: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Страница 17: ...C Industria 13 l Pol gono Industrial El Pedregar 08160 Montmel Barcelona Spain Phone 0034 93 390 42 20 Fax 0034 93 390 42 05 info htwspain com www htwspain com...

Отзывы: