HTW INNOVA HTWS026INNR32-INT Скачать руководство пользователя страница 16

14

Installation of indoor unit

Step 1: Choose installation place

Recommend the installation place to client and then confirm it with client.

Step 2:  Install wall-mounting frame

1. Hang the wall-mounting frame on the wall; make it in Verticalwith the level meter and

then make the screw fixing holes on the wall .

2. Drill the screw fixing holes on the wall with impact drill (the specification of drill head

should be the same as the plastic expansion particle) and then fill the plastic expansion

particles in the holes.

3. Fix the wall-mounting frame on the wall with tapping screws (ST4.2X25TA) and  then

check if the frame is firmly inatalled by pulling the frame.If the plastic expansion particle

is loose, please drill another fixing hole nearby.

Step 3:  Open piping hole

1. Choose the place of piping hole according to the direction of outlet pipe. The position

of piping hole should be a little lower than the wall-mounted frame, as below.

Left

Wall

Φ55

Right

Mark in the middle of it

Level meter

Rear piping hole

Wall

Space

to the

wall

above

150mm

Space

to the

wall

above

150mm

Φ55

Rear piping hole

Dimension: 910x303x200

2. Open a piping hole with the diameter of Φ55/Φ70 on the selected outlet pipe position. In

order to drain smoothly, slant the piping hole on the wall slightly downward to the outdoor

side with the gradient of 5-10°.

Indoor

Outdoor

5~10°

Φ55/Φ70

Note:

● Pay attention to dust prevention and take relevant safety

measures when opening the hole.

● The plastic expansion particles are not provided and

should be bought locally.

Содержание INNOVA HTWS026INNR32-INT

Страница 1: ...OWNER S AND INSTALLATION MANUAL INDOOR UNIT SPLIT ENGLISH INNOVA Thanks for choosing our product Please read carefully this manual before using the product HTWS026INNR32 INT HTWS035INNR32 INT...

Страница 2: ...lation This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste...

Страница 3: ...ly cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Do not wash the air conditioner with water to avoid electric shoc...

Страница 4: ...ch please press the switch with an insulating object except metal Do not step on top panel of outdoor unit or put heavy objects It may cause damage or physical injury Precautions Operation and Mainten...

Страница 5: ...ufacturer service agent or similarly qualified persons to avoid hazard The temperature of refrigerant circuit will be high please keep the interconnection cable away from the copper pipe The appliance...

Страница 6: ...place only the qualified person can perform the work Otherwise it may cause physical injury or damage Choose the place which is out of the reach of children and far away from animals or plants If it...

Страница 7: ...ndoor unit Display Actual product may be different from above graphics please refer to actual products NOTE Panel Horizontal louver Aux button Air inlet Filter Air outlet Wifi display PM2 5 display Te...

Страница 8: ...es of the panel push the panel upward according to the direction of arrow then open the panel Place the supporting rods which are on the left and right sides of the panel on the chute to support the p...

Страница 9: ...hair dryer to dry the filter to avoid deformation or fire hazard NOTE Clean and maintenance 2 Remove IFD module Pull out the IFD module by pressing the buttons at the left and right ends IFD module H...

Страница 10: ...er drainage pipe is damaged Checking after use season 1 Disconnect power supply 2 Clean filter and indoor unit s panel Notice for recovery 1 Most packing materials are recyclable materials Please disp...

Страница 11: ...replace them No display when operating remote controller Check whether remote controller appears to be damaged If yes replace it Fluorescent lamp in room Take the remote controller close to indoor un...

Страница 12: ...liminate the odour source Air conditioner operates normally suddenly Whether there s interference such as thunder wireless devices etc Disconnect power put back power and then turn on the unit again W...

Страница 13: ...occurs again after a few minutes please contact the professional person L2 No feedback signal of indoor unit fan Turn off restart after a few seconds if the code occurs again after a few minutes pleas...

Страница 14: ...be noobstruction near air inlet and air outlet 2 Choose a place where the condensation water can be dispersed easily and won t affect other people 3 Choose a place which is convenient to connect the...

Страница 15: ...be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 8 The temperature of refrigerant circuit will be high please keep the interconnection cable...

Страница 16: ...he plastic expansion particle is loose please drill another fixing hole nearby Step 3 Open piping hole 1 Choose the place of piping hole according to the direction of outlet pipe The position of pipin...

Страница 17: ...mouth 2 Pretightening the union nut with hand 3 Adjust the torque force by referring to the following sheet Place the open end wrench on the pipe joint and place the torque wrench on the union nut Tig...

Страница 18: ...ection wire to the wiring terminal according to the color tighten the screw and then fix the power connection wirewith wire clip 4 Put wiring cover back and then tighten the screw 5 Close the panel NO...

Страница 19: ...pass through the wall hole 2 Hang the indoor unit on the wall mounting frame 3 Stuff the gap between pipes and wall hole with sealing gum 4 Fix the wall pipe 5 Check if the indoor unit is installed f...

Страница 20: ...n the outlet pipe hole of indoor unit The water outlet can t be placed in water in order to drain smoothly Slant the drain hose slightly downwards The drain hose can t be curved raised and The drain h...

Страница 21: ...supply according to the voltage marked on the nameplate It may cause malfunction or damaging the parts Is electric wiring and pipeline installed correctly It may cause malfunction or damaging the par...

Страница 22: ...erating when first power on and turn on units to ensure the correct installation The steps of test operation is as below A Use remote controller to select cooling mode and set the temperature in 16 Ai...

Страница 23: ...C Industria 13 l Pol gono Industrial El Pedregar 08160 Montmel Barcelona Spain Phone 0034 93 390 42 20 Fax 0034 93 390 42 05 info htwspain com www htwspain com...

Отзывы: