LP-722 Rev. 000 Rel. 000 Date 9.3.19

WARNING

!

This Quick Start Guide DOES NOT replace the Use and Care Manual. Read and 

comprehend the Use and Care Manual before installing this product.

 

Step 1 - Before Installing

Quick Start Guide

Models: 3kW / 6.5kW / 10.5kW / 13kW

This product must only be installed by a qualified installer / service technician. 
The manufacturer will not be held liable for any damages resulting from im-

proper installation. 

Follow all local codes as well as the most recent edition of the latest version of 

the 

National Electrical Code, NFPA No. 70

.

When applicable, the installation must conform with Manufactured Home 

Construction and Safety Standards, Title 24 CFR, Part 3280 and/or CAN/CSA 

Z240 MH Series Mobile Homes. 

Failure to follow these instructions before installation could result in property 

damage, personal injury or death.

Step 2 - Installing

Inlet

Temp.

  

Single & Multipoint

110-120V

 

3.1-3.5 KW

240V

 

6.5 KW

240V 

10.5 KW

240V  

13 KW

40

º

F

Max Flow Rate

.7 GPM

1.1 GPM

1.4 GPM

50

º

F

Max Flow Rate

.5 GPM

.8 GPM

1.3 GPM

1.6 GPM

60

º

F

Max Flow Rate 

.5 GPM

1 GPM

1.6 GPM

2 GPM

70

º

Max Flow Rate

.6 GPM

1.3 GPM

2 GPM

2.5 GPM

Fixture Flow Rates

Shower  

1.5 GPM

(Range 1.5 -2.5)

Sink  

.5 GPM

(Range.5-1.5)

- Max Flow Rate Calculated for 105ºF Outlet Water Temperature
- Standard Install is 240V, if 208V is used Increase One Model 
   Size from the Chart Below

NOTICE

Any claims for damage or shortage in shipment must be filed immediately 

against the transportation company by the consignee.

A. Unpacking

B. Location Requirements

Choose a location for the water heater as centralized to the piping and electrical 

system as possible, and where domestic water piping will not be exposed to 

freezing temperatures. All piping should be insulated. Additionally, place the 

water heater so that the drain, controls, and inlets/outlets are easily accessible.

C. Wall Mounting

The mounting surface must be solid and secure. Do not install the unit above 

electrical boxes or junctions. Ensure the unit is level. Mount the unit to the wall 

with four (4) screws of at least one (1) inch in length. 

NOTICE

Use screws suitable for the wall material and the weight of the water heater. 

Failure to do so could result in property damages and damage to the water 

heater. Such damages ARE NOT covered by product warranty.

The appliance must be mounted horizontally, with water inlets and outlets at 

the bottom. See Figure 1.

WARNING

!

This water heater must be installed upright in the vertical position as described 

in this manual. DO NOT attempt to install this water heater in any other orien-

tation. Doing so will result in improper water heater operation and property 

damage, and could result in serious personal injury or death.

Figure 1 - DO NOT INSTALL THE WATER HEATER UPSIDE DOWN

AURES

SLIM MU

LTI

AURES

SLI

M MU

LTI

Step 3 - Plumbing

It is mandatory that all plumbing be done in accordance with federal, local, and 

state plumbing codes and practices.

The supplied pressure relief device (PRD) must be installed to protect against 

excessive pressures.

NOTE:

 It is highly recommended by the manufacturer to install water leak detec-

tion devices and automatic shutoff  valves in any water heater installation where 
a leakage of water could result in property damages. 

Figure 2 - General Piping Detail

Step 4 - Electrical Connection

The voltage requirement and dedicated wattage load for the heater is specified 

on the water heater rating label. Consult your local power company to deter-

mine if your electrical service is adequate for the additional load of the heater.

Make secure, appropriate wiring connections to the water heater per the 

National Electric Code.

Table 1 - Technical Specifications - *Wattage based on maximum voltage.

Connect the water 

inlet line to the entry 

point of the heater 

(left side inlet), and 

connect the outlet 

line to the water out-

let. Use a line that can 

withstand a minimum 

pressure of 58 psi. Us-

ing any other type of 

line will cause dam-
age. 

*Wattage 

(kW)

Voltage Amperage

Phase Circuit Breaker Size

Required Wire 

Size

3

120

25

1

1 x 30

10 AWG

6.5

240

27

1 x 30

8.5

36

1 x 40

6 AWG

10.5

44

1 x 50

13

54

1 x 60

4 AWG

AUTOMATIC WATER

SHUT-OFF VALVE 

(OPTIONAL)

HOT WATER OUTLET

BALL VALVE

CHECK VALVE

UNION

MIXING VALVE

(OPTIONAL)

PRESSURE 

RELIEF

COLD WATER INLET

LP-683-A
10/23/18

CATCH 

PAN

DRAIN

WATER LEAK

DETECTION

SENSOR (OPTIONAL)