Be sure to disconnect electrical power before performing service. Failure to do so could result in an electrical shock, property damage, 
serious personal injury, or death. 
 

 

This water heater is not designed or intended for use in space heating applications. Failure of a water heater due to unapproved use IS 
NOT covered by the warranty. 

B. WHEN SERVICING THE WATER HEATING SYSTEM 

 

To avoid electric shock, disconnect electrical supply before performing maintenance. 

 

To avoid severe burns, allow heater to cool before servicing. 

C. HEATER WATER 

 

Do not use petroleum-based cleaning or sealing compounds in a water heating system. Gaskets and seals in the system may 
be damaged. This can result in substantial property damage. 

 

Do not use “homemade cures” or “heater patent medicines”. Damage to heater, substantial property damage, and/or serious 
personal injury may result. 

D. INSTALLATIONS IN THE STATE OF CALIFORNIA 

 

California Law requires that residential water heaters must be braced, anchored, or strapped to resist falling or horizontal displacement 
due to earthquake motions. For residential water heaters up to 52 gallon capacity, a brochure with generic earthquake bracing 
instructions can be obtained from: Office of the State Architect, 400 P Street, Sacramento, CA 95814, or you may call 916-324-5315, or 
ask a water heater dealer. 
However, applicable local codes shall govern installation. For residential water heaters of a capacity greater than 52 gallons, consult the 
local building jurisdiction for acceptable bracing procedures. 

E. WATER CHEMISTRY 

 

Sodium less than 20mGL.  

 

Water pH between 6.0 and 8.0 

o

 

Maintain water pH between 6.0 and 8.0. Check with litmus paper or have it chemically analyzed by water treatment 
company. 

o

 

If the pH differs from above, consult local water treatment company for treatment needed. 

 

Hardness less than 7 grains 

o

 

Consult local water treatment companies for unusually hard water areas (above 7 grains hardness). 

 

Chlorine concentration less than 100 ppm 

o

 

Using chlorinated fresh water should be acceptable as levels are typically less than 5 ppm. 

o

 

Do not connect the boiler to directly heat swimming pool or spa water. 

o

 

Do not fill boiler or operate with water containing chlorine in excess of 100 ppm. 

 

Hardness:

 7 grains 

Chloride levels:

 100 ppm 

pH levels:

 6-8 

TDS:

 2000 ppm 

Sodium:

 20 mGL 

 

 

Failure of an electric element due to lime scale build-up on the heating surface, low pH, or other imbalance IS NOT covered by the 
warranty. 

PART 2 – PREPARE THE WATER HEATER 

 

UNCRATING HEATER

 

– Any claims for damage or shortage in shipment must be filed immediately against the transportation company 

by the consignee. Remove all sides of the shipping crate to allow the heater to be moved into its installation location. 
 
 

Содержание Everlast EV-12

Страница 1: ...oduct contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm NOTICE HTP reserves the right to make product changes or updates without notice and w...

Страница 2: ...rety before beginning any work Installation should be made in accordance with the regulations of the Authority Having Jurisdiction local code authorities and utility companies which pertain to this ty...

Страница 3: ...ble materials 0 top bottom sides and back Heater must have room for service 24 front and 6 sides are minimum recommended service clearances A combustible door or removable panel is acceptable front cl...

Страница 4: ...CA 95814 or you may call 916 324 5315 or ask a water heater dealer However applicable local codes shall govern installation For residential water heaters of a capacity greater than 52 gallons consult...

Страница 5: ...22 27 19 41 EV 30 30 4500 240 4 34 39 19 55 EV 30LB 30 4500 240 4 21 28 23 65 EV 45LB 45 4500 240 4 34 42 23 86 EV 50 50 4500 240 4 56 63 19 1 90 EV 80 80 4500 240 5 64 72 23 1 132 Table 1 Specificat...

Страница 6: ...result in substantial property damage severe personal injury or death 2 Check for nearby connections to System water piping Electrical power Choose a location for the water heater as centralized to th...

Страница 7: ...testing laboratory that maintains periodic inspection of production of listed equipment and materials Install the T P valve into the opening provided and marked for this purpose on the water heater so...

Страница 8: ...cold and hot water in branch supply lines Such valves are available from your local plumbing supplier Table 2 details the relationship of water temperature and time with regard to scald injury and ma...

Страница 9: ...REV 4 15 14 F INSTALLATION DIAGRAMS Figure 3 Piping Detail NOTE Drawing is meant only to demonstrate system piping concept The installer is responsible for all equipment and detailing required by loca...

Страница 10: ...V 4 15 14 Figure 4 Mobile Home and Point of Use Piping Detail NOTE Drawing is meant only to demonstrate system piping concept The installer is responsible for all equipment and detailing required by l...

Страница 11: ...the 120 volt model the white wire must be connected to the neutral leg 240V electrical installation should be done by a qualified licensed electrician or by your local electric utility All wiring mus...

Страница 12: ...protective cover should NOT be removed Set temperature indicator to desired temperature Replace insulation and the black access cover Turn on power to the heater See below for Thermostat adjustment E...

Страница 13: ...Screw the element clockwise into tank and tighten with the 1 socket wrench Be sure O ring seats properly STEP 6 Refill the tank with cold water STEP 7 Pressure check the tank for leaks around element...

Страница 14: ...for assistance Check the area around the water heater for flammable liquids or combustible materials If any are found remove from the area Vacation Extended Shut Off Periods During extended mild or w...

Страница 15: ...at 4 Manual Reset High Limit Switch ECO open a Thermostat s defective b Thermostat out of calibration c Heat build up due to loose wires d Defective High Limit Switch ECO 1 Turn switch ON 2 Rewire per...

Страница 16: ...LECTRIC ELEMENT W O RING EV 6 EV 20 1 2 6060P 187 ELECTRICAL BOX COVER 2 3 TP1500 3 4 T P VALVE 100XL 8 1 4 6060P 633 THERMODISC MOUNTING CLIP 2 5 TD1015 UPPER THERMOSTAT CONTROL 1 6 6060P 1009 THERMO...

Страница 17: ...17 LP 04 REV 4 15 14 NOTES...

Страница 18: ...nstallation Address Date of Installation Installer s Code Name Product Serial Number s Comments Installer s Phone Number Signed by Installer Signed by Customer IMPORTANT Customer Please only sign afte...

Отзывы: