6. Cosmetic Inspection Criteria
6.1 Classes definition of inspective area :
6.1.1 Description:
1.
D: Diameter /
L
: Length /
W
: Width /
N
: Number of defects/
S
: Distance from dot to dot
2. Inspecting distance: 30
±
5cm / Mechanical inspection angle
:
90 degrees /
LCM inspection angle
:
90
±
15 degrees / Inspection time:5 secs per surface.
3. Ambient illumination is to be 500-1100 lux
4. The inspection condition of Newton ring:
a. Inspection distance: 30cm / Inspection time: 5 sec
(Could check it after one hour)
b. Ambient illumination is to be 500-1000 Lux (Incandescent lamp)
c. Inspection should be performed under the condition that LCD
Class A
Class B
Class D
Class C