CHAPTER 6 –LEAKAGE CURRENT MEASUREMENT
This is a quick method to measure if any abnormal leakage current on main board which caused high
power consumption compare to GOOD main board.
(1) Requirement
:
-
Power Supply
- Micro-current Meter
- Current series JIG
-
CABLE
-
Battery JIG
1.Equipment need:
A. Power Supply (set at 4 V /1A).
B. Micro-Current Meter (support 0.5mA ~ 1A).
2. Fixture needed
C. Cable
D. Battery with extension cable
E. Current series jig.( with black and red cable)
B
A
D
E
C