5.3.
LOW
Ω
– SETTINGS FOR CONTINUITY TEST WITH 200MA
The purpose of this measurement is to test the continuity of protective conductors and
equipotential ones (e.g. from rod to earth and connected foreign earth) and earth rods of
SPDs on PV installations. The test must be carried out using a test current > 200mA
according to the prescriptions of IEC/EN62446 guideline
5.3.1. Instrument settings
1. Position the cursor onto
LOW
Ω
by using the arrow keys
and confirm with
ENTER
. The display shows the following
screen:
2. Press the
ENTER
key. The instrument shows the following
options:
Settings
and
Leads calibration
3. Use the arrow keys
to select “
Settings
” and confirm with
ENTER
. The instrument shows the following screen:
4. Using the arrow keys
it is possible to set the maximum
limit value of Rpe resistance which the instrument uses as a
reference while measuring.
5. Press the
SAVE
key to save the settings made; the message
“Data saved” will be displayed for a few seconds. Press the
ESC/MENU
key to exit without saving and go back to the
previous screen.
select “
Settings
” and confirm with
ENTER
. The instrument shows the following screen:
CAUTION
The settings saved for max RPE also affect the settings for the Continuity test
contained in the IVCK measurement (MENU
IVCK)
5.4.
M
Ω – SETTINGS FOR INSULATION MEASUREMENT
5.4.1. Instrument settings
1. Position the cursor onto
M
Ω
by using the arrow keys
and
confirm with
ENTER
. The display shows the following screen: