XL421 - XL422 

 

 

1. SAFETY PRECAUTIONS AND PROCEDURES 

This meter has been designed in compliance with EN 61010 directive. For your own safety 
and to avoid damaging the instrument we suggest you follow the procedures hereby 
prescribed and to read carefully all the notes preceded by the symbol 

 

WARNING 

 

 

Should you fail to keep to the prescribed instructions you could damage the 
instrument and/or its components or endanger your safety. 

 
Take extreme care of the following conditions while taking measurements: 

)

  Do not performing any measures in humid or wet environments. 

)

 Do not use the meter in presence of explosive gas (material), combustible gas 

(material), steam or dust. 

)

  Do not touch the circuit under test if no measurement is being taken. 

)

 Do not use the instrument if it seems to be malfunctioning (i.e. if you notice 

deformations, breaks, leakage of substances and so on). 

 
The herewith symbols are used: 
 

 

Caution: refer to the instruction manual; an improper use may damage the 
instrument or its components 

 

 

 

Danger high voltage: risk of electrical shocks 

 

 

 

De-energize the plant under test before connecting the instrument 

 

 

 

Double insulated meter 

 

 

 

AC voltage and current 

 

1.1 PRELIMINARY 

INSTRUCTIONS 

)

  This instrument has been designed for use in environments of pollution degree 2 up to 

2000m high. 

)

 It can be used for 

CURRENT

 measurements up to 2500A on installations with 

overvoltage category CAT III 1000V

 to ground or CAT IV 600V

 to ground. 

)

  Please use the standard safety precautions aimed at: 

9

  Protecting you against dangerous electric currents. 

9

  Protecting the instrument against incorrect operations. 

)

  Do not test circuits exceeding the current and voltage limits. 

)

  De-energize the plant under test before connecting the instrument. Take all the safety 

precautions before taking actions on the plant. 

)

  Do not perform any test under environmental conditions exceeding the limits indicated 

in this manual (ref. par. 10.2). 

)

  Make sure that batteries are correctly installed. 

)

 Only the accessories supplied with the instrument guarantee compliance with the 

safety standards. They must be in good conditions and must be replaced, if necessary, 
with identical models. 

 

 

EN - 2

www.

.com

[email protected]

1.800.561.8187

Содержание XL421

Страница 1: ...ENGLISH User s manual Copyright HT ITALIA 2007 Release EN 1 02 13 06 2007 www com information itm com 1 800 561 8187...

Страница 2: ...6 6 MEASURING PROCEDURE 7 6 1 Using the instrument in a Single Phase plant 7 6 2 Using the instrument in a Three Phase plant 9 7 LED MESSAGES DESCRIPTION 11 8 CONNECTION OF INSTRUMENT TO PC 11 9 MAIN...

Страница 3: ...s Danger high voltage risk of electrical shocks De energize the plant under test before connecting the instrument Double insulated meter AC voltage and current 1 1 PRELIMINARY INSTRUCTIONS This instru...

Страница 4: ...the source of low voltage installations Examples are electricity meters and measurements on primary overcurrent protection devices and ripple control units Measurement category III is for measurement...

Страница 5: ...ingle phase or three phase plant Where not expressly indicated the characteristics are common for both models The meter can monitoring a plant for a long time thanks to a sophisticated memory managing...

Страница 6: ...ph 10 1 2 For battery fitting operation procedure please see paragraph 9 2 WARNING The meter after fitted batteries is always continuously ON also if STATUS and ALARM LED are OFF Pressing of START STO...

Страница 7: ...rnal clock Set instrument date and time Check battery status How to operate 1 Connect the instrument to PC COM using included serial cable 2 Run DATALINK software 3 Choose the correct COM port with th...

Страница 8: ...n the middle of the head 5 Re energize the plant under test 6 How to start a Recording If no recording was performed or if the recording data was already downloaded to a PC pressing and keeping the ST...

Страница 9: ...ion is possible During Recording operations RS 232 serial communications to PC is not possible 8 Stop a Recording To stop a Recording pressing START STOP key and keep it pressed for 3 seconds The STAT...

Страница 10: ...he middle of the head 5 Re energize the plant under test 6 How to start a Recording If no recording was performed or if the recording data was already downloaded to a PC pressing and keeping the START...

Страница 11: ...ion is possible During Recording operations RS 232 serial communications to PC is not possible 8 Stop a Recording To stop a Recording pressing START STOP key and keep it pressed for 3 seconds The STAT...

Страница 12: ...NNECTION OF INSTRUMENT TO PC Connection of the instrument to a PC is made with a serial cable supplied with the instrument To download data to the PC after installation of DATALINK software keep to th...

Страница 13: ...ING Only experts and trained technicians should perform this operation Remove the flexible head from the conductor under test before replacing the batteries 1 Stop the recording if necessary remove th...

Страница 14: ...ht 2000m Overvoltage category CAT III 1000V to ground CAT IV 600V to ground 10 1 2 General data Mechanical characteristics Size 120 L x 80 W x43 D mm Max diameter cable clamped 174mm Head length 600mm...

Страница 15: ...Damages caused by incorrect shipping procedures Damages caused by repair service trials of unauthorized people Modifications to the equipment without explicit authorization of our Technical Dept Adapt...

Отзывы: