1. 

Upon power-up the unit will resume display of time and 

elapsed time. 
2. 

To set the React unit,  press and hold the letter "R" in the 

word React for approximately five seconds, or press the RESET and 

the MODE buttons at the same time and hold for 5 seconds. The 

units will activate the set-up mode and a blinking 0 in the upper 

[orange] row and numbers in the lower [green] row. 
3. 

Time of Day  With the red 0 blinking press the START/STOP 

switch and the first green digit will begin to blink, Use the MODE 

switch to set the first digit.  Press the START/STOP to activate the 

second digit and use the MODE to set it.  Repeat for the rest of the 

digits. Upon completion of the time set, a red blinking 1 will 

appear. 
4. 

Date.  With the red 1 blinking press the START/STOP switch and the first green digit will begin to 

blink. Continue as in 3 above to set the date. 
5. 

Brightness.  With the red 2 blinking press the START/STOP switch and the last green digit will begin 

to blink.  Pressing MODE will change the brightness from 0 [dim] to 6 [bright]  Do not set at over 6. 
6. 

Mode,  With the red 3 blinking press the START/STOP switch and the last green digit will begin to 

blink.  Press the MODE switch to change the Mode as follows: 

7. 

12/24 Hour  With the red 4 blinking press the START/STOP switch and the last green digit will begin 

to blink.  Pressing MODE will change the operation for the time of day clock to 

8. 

4/6 Digit Display  With the red 5 blinking press the START/STOP switch and the last green digit will 

begin to blink.  Pressing MODE will change the operation for the time of day clock to 

9. 

Single/Dual Display  With the red 6 blinking press the START/STOP switch and the last green digit 

will begin to blink.  Pressing MODE will change the operation for the time of day clock to 

10.  Version No.  With the red 7 blinking the lower row will display the version number of the unit's 

program. 
11.  Self Test  With the red 8 blinking press the START/STOP switch and the last green digit will begin to 

blink.  Pressing MODE will cycle all digits through all numbers for testing. 
12.  After self test the unit will revert to operational mode.  After setting any of the above, operational 

mode can be attained by pressing RESET.  Your last changes will be entered only if the red digit is 

blinking 

when you press RESET.

 

 

 

elapsed timer only 

time of day only 

date & time of day 

elapsed timer & time of 

day 

date & elapsed timer & 

time of day 

 

 

0  24 hour time of day display 

1  12 hour time of day display 

0  24 hour time of day display 

1  4 digit display for time of day HH:MM 

0  Dual display  [elapsed timer in red on 

top, time of day in green on bottom 

Single display, MODE will display either 

elapsed time  

or time of day in top 

[red] row 

Operating Instructions 