5 Installation and commissioning
42
HSD S.p.A. © - h0104k01a.fm291119
Transmission speed setting (bit-rate)
The servo-motor is supplied with an initial bit-rate value of 500 Kbit/s.
If the value is not aligned with the one on the numerical control, it is necessary to follow the bit-rate
value setting procedure described below.
To set the required bit-rate value (DSW2), it is necessary to start the servo-motor with switch 6 On,
switch 5 Off and switches 1 to 4 set according to the bit-rate value required, as shown in the table
below.
Immediately after switch-on, the green servo-motor LED lights up for about 1 second. After this, if
the required bit-rate value has been successfully saved to the flash memory, it will start to flash
periodically with a number of blinks based on the bit-rate that has been selected.
If the dip-switch configuration is not one of those envisaged, the bit-rate value will remain as
before. If there are flash storage problems, the green LED will begin a 4-second flashing sequence
(2 seconds ON and 2 seconds OFF).
At the end of the procedure the servo-motor must be turned off and the dip-switch configuration
restored.
Dip-switch (DSW2)
Bit-rate
value
Flash*
to confirm
(green led DL3)
*
The LED flashes a certain number of times, followed by a pause before the "N" flashes are repeated.
6
5
4
3
2
1
On
Off
Off
Off
Off
On
1 Mbit/s
1
On
Off
Off
Off
On
Off
800 Kbit/s
2
On
Off
Off
Off
On
On
500 Kbit/s
3
On
Off
Off
On
Off
Off
250 Kbit/s
4
On
Off
Off
On
Off
On
125 Kbit/s
5
Содержание SM 137 D
Страница 2: ......
Страница 4: ...Information about the publication 4 HSD S p A H5834D0189 fm291119 ...
Страница 8: ...Table of contents 8 HSD S p A H5834D0189TOC fm291119 ...
Страница 9: ...Preliminaries ...
Страница 10: ......
Страница 16: ...1 Preliminary information 16 HSD S p A h0101k00a fm291119 ...
Страница 20: ...2 Safety information 20 HSD S p A h0115k00a fm291119 ...
Страница 21: ...Descriptions ...
Страница 22: ......
Страница 26: ...3 Main parts 26 HSD S p A h0102k00a fm291119 ...
Страница 48: ...5 Installation and commissioning 48 HSD S p A h0104k01a fm291119 ...
Страница 49: ...Maintenance ...
Страница 50: ......
Страница 52: ...6 Maintenance 52 HSD S p A h0107k00a fm291119 ...
Страница 53: ...Appendices ...
Страница 54: ......
Страница 60: ...A Technical characteristics 60 HSD S p A h0124k00a fm291119 ...
Страница 62: ...B Disposal 62 HSD S p A h0109k00a fm291119 ...
Страница 70: ...Analytical index 70 HSD S p A H5834D0189IX fm291119 ...
Страница 71: ......