- 35 -
Display notification Meaning
Both setting procedures were successful.
Example of the NOK setting process:
Process 1 NOK, 2 processes remaining. The error notification can be
removed by clicking on the yellow button.
The tension is displayed. After sliding the battery the notification
„Trigger“ appears. If the trigger is not released the battery voltage is
displayed.
NOK must be confirmed separately by the worker clicking on the
yellow button on the display.
Maximum temperature of the motor exceeded, consult the manu-
facturer.
Maximum logic voltage exceeded, tool must be repaired!
Maximum permissible force exceeded, consult the manufacturer.
Maximum permissible current exceeded , consult the manufacturer.
Maximum temperature of the control exceeded, consult the manu-
facturer.