HRS 176-7317 Скачать руководство пользователя страница 8

2. Hi-Flex結線プレス各部の名称/

Configuration of the Hi-Flex connection press

 

2. Hi-Flex結線プレス各部の名称/

Configuration of the Hi-Flex connection press

 

  

2-1.  結線プレス/

Connection press

 

2-1.  結線プレス/

Connection press

 

  
この結線プレスは Hi-Flex シリーズコネクタ全機種の結線作業にご使用できます。 

この結線プレスは Hi-Flex シリーズコネクタ全機種の結線作業にご使用できます。 

The connection press is applicable for connecting all types of the Hi-Flex Series connectors.

 

The connection press is applicable for connecting all types of the Hi-Flex Series connectors.

 

HRS No. 

HRS No. 

Product number 

Product number 

Height 

Height 

Width 

Width 

Depth 

Depth 

Weight

Weight

550-0082-2 Hi-Flex 

Connection press

440mm 160mm 350mm

13kg

HRS No. 

製品番号 

高さ 

幅 

奥ゆき 

重畳

550-0082-2

Hi-Flex  結線プレス

440mm 

160mm 

350mm

13kg

 

D.

 

ハンドル部/

Handle section 

C.

 

ラチェット部/

Ratchet section 

B.

 

ガイドプレート取付け部/

Guide-plate mounting section 

各  部  の  名  称/

Name of parts 

A.

 

加圧ブロックの取付け部/

Pressure-block mounting section

  

2-2.  適合治具/

Applicable jigs

 

2-2.  適合治具/

Applicable jigs

 

  
表-1 適合治具一覧表を参照の上、各シリーズと極数に合わせた指定加圧ブロックとガイドプレートを準備して下さい。

 

表-1 適合治具一覧表を参照の上、各シリーズと極数に合わせた指定加圧ブロックとガイドプレートを準備して下さい。

 

A pressure block and guide plate specified according to the type of Series and the number of poles of your connector should be 
prepared referring to the Listing of the HIF Series connection jigs and applicable jigs in Table 1.

 

A pressure block and guide plate specified according to the type of Series and the number of poles of your connector should be 
prepared referring to the Listing of the HIF Series connection jigs and applicable jigs in Table 1.

 

  

加圧ブロック/

Pressure block

 

ガイドプレート/

Guide plate

 

  
  
  
  
  
  
  
  
  
  
  
  
  
ガイドプレートおよび加圧ブロックは、当社製品以外のコネクタには使用できません。また、当社結線プレスおよび
適合治具以外の結線プレスその他を使用した場合の結線完成品は、保証致しかねますのでご注意下さい。 

ガイドプレートおよび加圧ブロックは、当社製品以外のコネクタには使用できません。また、当社結線プレスおよび
適合治具以外の結線プレスその他を使用した場合の結線完成品は、保証致しかねますのでご注意下さい。 

The guide plates and pressure blocks are only applicable for connecting the HIROSE connectors. 

The guide plates and pressure blocks are only applicable for connecting the HIROSE connectors. 
Be sure to remember that HIROSE does not guarantee the connection quality of connectors if any of tools including connection 
presses other than those available from HIROSE is used.

 

Be sure to remember that HIROSE does not guarantee the connection quality of connectors if any of tools including connection 
presses other than those available from HIROSE is used.

 

-

Aug.1.2019 Copyright 2019 HIROSE ELECTRIC CO., LTD. All Rights Reserved.

Содержание 176-7317

Страница 1: ...to read this Instruction Manual carefully before using it to secure safety in operation In addition save this Instruction Manual so that it is available whenever necessary for review HIROSE ELECTRIC C...

Страница 2: ...ction Tool This Manual describes the procedure for connecting ribbon cables to the HIF connectors and the details of the tool Be sure to read this Instruction Manual carefully before using it to secur...

Страница 3: ...I 1 1 1 2 1 2 3 4 i Aug 1 2019 Copyright 2019 HIROSE ELECTRIC CO LTD All Rights Reserved...

Страница 4: ...n 1 Such safety devices as the safety cover and the like are not attached to this tool When performing connection use this tool while fully considering so that the fingers or the like are not caught i...

Страница 5: ...able jig and for adjusting the ratchet 4 Cutting allowance of cables and cautions to be taken when cutting them 5 Procedure for connecting the HIF2 IC type and DIP type 6 Procedure for connecting the...

Страница 6: ...HIF2C 60PB 550 0156 7 HIF3 GPA2 HIF3 A B BA BB J N 550 0133 1 HIF1 A 01 I C H I I B 2 F H I F 2 I H I F 2 C I 6 10 14 16 20 26 30 34 40 50 60 64 HIF3 HIF3A HIF3B HIF3BA HIF3BB HIF3J HIF3N HIF3 6PD 2 5...

Страница 7: ...e pressure block is included HIF3 16PD 2 54R 550 0072 9 HIF3 GPD16 exclusive pressure block is included HIF3 20PD 2 54R 550 0073 1 HIF3 GPD20 exclusive pressure block is included HIF3 26PD 2 54R 550 0...

Страница 8: ...mber of poles of your connector should be prepared referring to the Listing of the HIF Series connection jigs and applicable jigs in Table 1 A pressure block and guide plate specified according to the...

Страница 9: ...ed product name is in white of the pressure block C should be faced toward you 3 1 Fig 3 1 Recessed part A of pressure block holder Pressure block holder Projected part B of pressure block Pressure bl...

Страница 10: ...head bolts supplied accessories diagonally as a c and b d and secure them with the M5 hexagonal wrench key See Fig 3 4 For the HIF2 lower the press handle so that the guide pins of the pressure block...

Страница 11: ...From this state securely tighten the bolt while checking how the ratchet is released During the adjustment also check the following carefully 1 1 When you want to return the handle to its home positi...

Страница 12: ...nsion of allowance to dimension L in completed connection drawing example Without clamp With clamp HIF2 IC type HIF2 14 12 5mm HIF2 14 12 5mm allowance HIF2 16 12 5mm HIF2 16 12 5mm allowance HIF2 24...

Страница 13: ...jects from the cutting plane 5 HIF2 I C cedure for connecting the HIF2 IC type and DIP type Pro 1 IC 5 1 1 Place a protector on the guide plate For the IC type the protector may be oriented in either...

Страница 14: ...s IC IC type connector DIP type connector A type B B type Stopper Stopper Stopper Stopper A type 5 2 Fig 5 2 B B type 3 3 Depress the handle until the ratchet locks in place After completion of connec...

Страница 15: ...HIF2 IC type DIP type with a clamp is not used Correct the corrugation of cable fits in the corrugation groove of the protector Wrong the corrugation of cable does not fit in the corrugation groove o...

Страница 16: ...ector may be oriented in either direction Protector Stopper Protector common to all number of poles Guides 6 1 Fig 6 1 2 6 2 2 Place the cable properly See Fig 6 2 Wrong 6 2 Fig 6 2 Not flush Not stra...

Страница 17: ...ype classification Determine a desired connection type according to the direction of the mark on the cable and the filled triangle mark on the connector mark Stopper Stopper 6 3 Fig 6 3 A type B type...

Страница 18: ...unit as an accessory Pressure block Depress the handle Stopper Push the take out lever 6 4 Fig 6 4 5 6 5 6 6 HRS 5 Fold the cable which has been connected Fig 6 5 as shown in Fig 6 6 press the top end...

Страница 19: ...ndling the product after the completion of connection Ca 1 2 HIF2 HIF3 3 HIF2 4 1 Do not re use the connector and cable which have been used once since the re use can cause a malfunction 2 Be sure to...

Страница 20: ...4R S A F2 HIF2 D 2 54R S type HIF2 D 2 54R S type HIF2B D 2 54R S A type the example diagram indicates the F2 type HIF2B D 2 54R S A type the example diagram indicates the F2 type AA AA type AA AA typ...

Страница 21: ...S B HIF2B D 2 54R S B type HIF2B D 2 54R S B HIF2B D 2 54R S B type AA AA type AA AA type AA AA type AA AA type Cable mark Dip type Dip IC IC type AB AB type AB AB type AB AB type AB AB type Cable ma...

Страница 22: ...circuit diagram for HIF3 AB AB type Cable mark A AB type AD AD type AD AD type CD CD type CD CD type AD AD type CD CD type Cable mark D Cable make D C Aug 1 2019 Copyright 2019 HIROSE ELECTRIC CO LTD...

Страница 23: ...AC AC type CC CC type AA AA type AC AC type Cable mark Cable mark Cable mark C A AA CC CC type AA type Aug 1 2019 Copyright 2019 HIROSE ELECTRIC CO LTD All Rights Reserved...

Страница 24: ...tact our Marketing Department 4 It should be understood that notwithstanding the aforementioned item 3 we assume no liability to any claim for loss or failure to earn profit resulting from the use of...

Страница 25: ...6235 Phone Tele Fax 805 5227958 805 5223217 Hirose Electric GmbH Zeppelinstraze 42 73760 Ostfildern Kemnat Phone Tele Fax 0711 4560021 0711 4560729 Hirose Electric UK Ltd Crownhill Business Centre 22...