background image

Read all the instructions before installation. This instruction manual is to 
be left at the installation site. These Floodlights must only be connected to 
a 230V-240Va.c. 50Hz supply by a licensed electrician.

Where to mount your flood light:

1.  Installation is to be made in dry weather conditions. 
2.  Choose a wall mount position that is in a sheltered location (e.g under 

the eaves of the house). A mounting height of greater than 2m 
is recommended.

3.  Do not operate in close proximity to combustible materials or 

substances affected by heating or drying. Keep a minimum distance 
of 0.5m from adjacent objects.

Installation:

Installing a wall switch adjacent to the power source is recommended.
1.  Remove mounting bracket from the fitting and use to mark position on 

the wall/ceiling. 

2.  Mount the bracket on the wall/ceiling. Ensure the method of fixing can 

support up to a 10kg weight.

3.  Reattach fitting to the bracket.* Do not tighten bolts completely 

to allow for mains wiring termination.

*  Ensure that cord gland faces downwards in the final mounting 

position (as shown in Fig.1)

4.  Choose rubber-sheathed 3-core circular cord, H05RN-F 3G 1mm2 

(not supplied) for the mains wiring.

5.  Remove junction box cover, strip insulation from cord and insert in to 

cord gland. Wire up as shown in Fig 2.

6.  Replace junction box and tighten screws to ensure a weatherproof 

seal. Tighten gland

7.  Orient fitting to desired position and tighten bolts completely.

Instruction Manual

Forta LED Floodlight

Cat. Nos. LFL0110WBL, LFL0120WBL, LFL0130WBL, LFL0140WBL

Fig 1

1  Lamp Cover Screw
2  Terminal Block
3  Junction Box Cover Screws (x 4pcs)
4  Wall Mounting Bracket Screws (x 2pcs)
5  Wall Mounting Bracket
6  Gland
7  Power Cable (not provided)

Blue wire to Neutral

N

N

L

L

Green-yellow to earth

Brown wire to switch

White wire to light

Green-yellow to light

White wire to light

Fig 2

1

3

4

7

6

5

2

FORTA

LFL0130WBL