background image

Instruction Manual

Inline Exhaust Fan Kit – 100mm & 150mm 

Cat. No. EFIL100SQWE, EFIL150SQWE 

Read through these instructions completely before commencing installation. Retain for future use.

Cat No.

EFIL100SQWE 

EFIL150SQWE

Supply voltage

230-240V a.c.  50Hz 

Power rating

30W

60W

Protection class

Class II

IP rating

IP44

Draught stopper

Yes (PET Sheet)

Duct diameter

Ø100mm

Ø150mm

Engine size

290 x 200 x 210mm

290 x 230 x 250mm

Engine weight

1.9kg

3.0kg

Power cord length

1m

Ceiling cut-out size (for inlet & outlet grilles)

Ø110mm

Ø160mm

Max airflow (m

3

/hr) 

Duct length

Low Speed (I)

High Speed (II)

Low Speed (I)

High Speed (II)

No duct

200

255

450

555

1m per side (total 2m)

100

125

310

390

2.5m per side (total 5m)

90

115

270

335

Specifications

Features

Please Read Carefully

1

2

3

The inline fan is designed to extract steam and odours from a bathroom and expel it to the exterior through an eave outlet. It is also suitable for 
extracting air from one room and expelling it to another room (heat distribution).

The fan engine is fitted into the ceiling, well away from the inlet. This inline feature allows the inlet grille to be mounted in wet areas (near the splash 
zones of bathrooms) or even above the shower. And because the motor is in the ceiling cavity (away from the inlet grille), noise from the fan is minimal.

1.  This product shall be installed in accordance to AS/NZS 3000 Wiring Rules.
2.  This product is meant for indoor use only.
3.  Regulations concerning the discharge of air must be fulfilled. Local building codes may require venting to the outside.
4.  Do not locate the inlet grille above a stove. This product is not to be used in conjunction with a kitchen range hood exhaust system.
5.  The minimum length of duct between the fan engine and the inlet / outlet grilles is 200mm.
6.  Cross Ventilation: 

 Ventilation products must have an adequate source of external air to ensure rated performance.