HPM Legrand warrants the following on the Instant Heat from the date of purchase:
• 5-year warranty on materials and workmanship (excluding heat lamps and centre light).
•  2-year warranty on heat lamps and centre light. These goods come with guarantees 

that cannot be excluded under the Australian and New Zealand Consumer Laws. You 
are entitled to a replacement or a refund for a major failure and for compensation for 
any other reasonably foreseeable loss or damage. You are also entitled to have the 
goods repaired if the goods fail to be acceptable quality and the failure does not amount 
to a major failure.

See the Warranty card enclosed with this product for further details.

Customer Service

For all Customer Service and Technical Support  
please call Monday to Friday during business hours.

HPM Legrand Australia
1300 369 777
www.hpm.com.au

HPM Legrand New Zealand
0800 476 009
www.hpm.co.nz

ABN: 31 000 102 661

LE06397AKA

Ducted Instant Heat 3-in-1

2 Heat Lamp model: BH2DWE 

4 Heat Lamp model: BH4DWE

Instruction Sheet

1

2

Rating

The Ducted Instant Heat 3-in-1 are ceiling mounted heat lamp appliances combining the functions of heater, extraction fan and luminaire.

Read through these instructions completely before commencing installation. Retain for future use. 

This product shall be installed by a licensed electrical contractor or similarly qualified person.

CAUTION: 

Regulations concerning the discharge of air must be fulfilled. Local building codes may require venting to the outside. The Instant Heat is 

for ceiling mounting only, with the lowest point to be at least 2.2 metres above floor level. It is not intended to be installed in wardrobes or 

within 300mm of walls. Please note there is a danger of combustion if placed too close to curtains or other flammable materials. Under no 

circumstances must the Instant Heat be covered with insulating material within the ceiling space.  

Instant Heat must not be installed where there is a possibility of water splashing on to the lamps. Locate in accordance with the 

requirements of the Wiring Rules AS/NZS 3000 relating to damp situations. This means that no part may be located directly above any part 

of the bath or shower recess or enclosure. For unenclosed showers refer to the Wiring Rules conditions.

Note: Steam will only be removed if there is sufficient flow of air through the room. Ensure adequate inlet openings in the room are 

provided, for example through windows, vents or under the door. Air-flow paths from room inlets to fan should ideally pass over surfaces 

where condensation may form.

Model: 

BH2D 

BH4D

Supply voltage: 

230-240Vac 

230-240Vac

Frequency: 

50Hz 

50Hz

Max Power Consumption:  840W 

1570W

Disclaimers

Trouble shooting

I.  Use the Instant Heat only as described in this instruction. 
II.   A switch disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
III.   This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack 

of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person 

responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

IV.   This appliance is intended for household use and similar purposes. It is not suitable for use in an environment heavily laden with 

dust. Under these conditions the life of the fan motor can be significantly reduced.

V.   This product contains no serviceable parts and no attempt should be made to repair this product. If the product is faulty it should 

be discarded.

VI.   This product must be cleaned periodically from dust and other contaminants with a damp cloth. Aggressive cleaning agents and 

solvents should never be used.

VII.  Airflows listed in this instruction sheet indicate the product performance. Refer to the BCA (Building Code of Australia), or similar, 

for the appropriate airflow required for a particular installation.

VIII.  Ventilation products must have an adequate source of external air to ensure correct performance.
IX.  This product should not be enclosed in thermal insulation as it may cause the unit to overheat.
X.  This product has been designed for domestic or similar uses and is not suitable for a commercial installation.
XI.   This product utilises intellectual property in the form of registered designs, trademarks, and/or patents. Such intellectual property 

remains the property of HPM Legrand in all cases.

XII.  HPM Legrand reserves the right to modify the specification of this product at any time.

This Instant Heat is fitted with a thermal cut-out to provide over-temperature protection. If the heat lamps begin to 

switch ON/OFF intermittently this may indicate the unit was wired incorrectly, allowing the lamps to operate without 

the fan running. To rectify please check your installation.

BH2D

BH4D

  What’s in the box

BH2D

BH4D

Housing

1 piece

1 piece

Infrared Heat Lamps (275W)

2 pieces

4 pieces

Light globe (11W CFL)

1 piece

1 piece

Instructions

1 piece

1 piece

Warranty card

1 piece

1 piece

Hole-cutting template

1 piece

1 piece

Ducting (3m x 

Φ

150mm)

1 piece

1 piece

Duct holder

1 piece

1 piece

External grille

1 piece

1 piece

Wall switch plate

1 set

1 set

Duct tape and cable ties

1 set

1 set

6

7

8

Отзывы: