background image

1

  

Rating

Supply voltage: 

230-240Vac

Frequency: 50Hz
Max Power Consumption:  375W
(May be connected to a light or power circuit if loading permits.)

2   Please read carefully

Read through these instructions completely before commencing installation.
The HPM Single Lamp Instant Heat is designed for installation in the 
ceilings of toilets and bathrooms where heat is required. The appliance 
is fitted with a plug and lead for ease of installation. Two or more Instant 
Heats may be required for larger bathrooms.
The infrared lamps heat by direct radiation rather than by heating the air in 
the room, so the Instant Heat should be located directly over the drying area.
Instant Heat must not be installed where there is a possibility of water 
splashing on to the lamps. Locate in accordance with the requirements of 
the Australian/New Zealand Wiring Rules AS/NZS 3000 relating to damp 
situations. This means that no part may be located directly above any part 
of the bath or shower recess or enclosure. For unenclosed showers refer to 
Wiring Rules conditions.
A minimum volume of 1m

3

 is required around each Instant Heat to prevent 

build-up of heat. Additional Instant Heats may be placed side-by-side if at 
least 1m clearance between them is observed.
All wiring must be carried out by a licensed electrician.

3   Location

The Instant Heat is for ceiling mounting 
only, with the lowest point to be at least 2.2 
metres above floor level. It is not intended to 
be installed in wardrobes or within 300mm 
of sides of walls, as per Figure 1. There is a 
danger of combustion if placed too close to 
curtains or other flammable materials.

4   Ceiling preparation and installation

The clearances between Instant Heat and adjacent building members 
shown in Figure 2 shall be observed. Thermal insulation or similar material 
shall not be placed on top of the unit, and adjacent material to the side 
shall be kept clear to a minimum distance of 150mm (Fig 3).
Joists, beams and rafters shall not be cut or notched to install Instant Heat. 
After determining the location of Instant Heat use the template to mark out 
and cut the aperture (Fig 4). 

5   Fixing to ceiling

Remove all packaging before installation. 
Remove fascia and lamp. Check that 
power to the circuit has been isolated 
before connecting plug to mains supply. 
Push the Instant Heat body into the 
opening, ensuring the retractable clips do 
not catch on the hole cutout. Once fully 
recessed, push in the 3 clips and use a 
screwdriver to tighten.

6   Final assembly

Refasten the fascia cover which is designed to snap onto the housing flange 
sitting flush against the ceiling. Insert the lamp into the socket, tightening 
well to ensure good electrical contact and long life. Wipe the fascia and the 
bulbs clean. Reconnect the power from the mains and test.

7   Wiring

The Instant Heat may be dimmed for variable heat output. The recommended 
dimmer is Excel Life Cat EM700TR.
Wall switches/controls should be located in a position that is not within reach 
of a person in the bath or shower.

Instruction Sheet

Single Lamp Instant Heat

Cat. BH1WE / BH1MS

Joist

Joist

>150mm

>150mm

Thermal

insulation

Thermal

insulation

Thermal

insulation

Thermal

insulation

Fig 3

> 100mm

clearance

2.2M Min.

Jois

t

> 30mm

clearance 

Fig 2

Fig 4

Instant

Heat

body

Fig 5

>300mm

Wall

>300mm

Fig 1

Отзывы: