Action
Verify the license details.
A storage scan fails
Symptom
A storage scan fails
Solution 1
Cause
There are insufficient expansion licenses applied to allow the entire expansion to complete (in this case,
no expansion will take place until sufficient licenses are present for all added storage).
Action
Verify that all licenses have been applied.
Solution 2
Cause
There are failed or predictive fail disks in either the existing or newly added storage.
Action
Verify the status of the disks and replace disks, if required.
Solution 3
Cause
The SAS cabling between the head server and the disk enclosures is not connected securely.
Action
Verify the physical connections.
Solution 4
Cause
There are foreign logical drives or volumes already present on the attached storage. These are identified
as an unsupported or invalid storage configuration and the
dev-id
of the volume is provided in the error
message.
Action
Delete the storage, as described in the
StoreOnce 5500 System Maintenance and Service Guide
.
54
A storage scan fails