Using the holes provided in the rear rack rails, install the tie wraps and route external cables, as required,
as shown in following figure:
5.
Connect all power cords to the facility power source.
2U Rail instructions
For detailed instructions on installing the HPE rack rails into square and round hole racks for HPE 2U Storage
system, see
HPE Rack Rail Kit installation instructions document
, that is part of the shipped rail kit.
Cabling instructions
The iLO network port is used to remotely manage the StoreEasy 1X60 hardware and allows administrators to
launch a remote console session to the system. HPE recommends that you connect the iLO port to your
management network. The iLO port is preconfigured to obtain an IP address through DHCP. If your
environment does not support DHCP, use a KVM and configure iLO to use a static IP address.
18
2U Rail instructions