Item LED
Status
Definition
Flashing green
The drive is doing one of the following:
• Rebuilding
• Performing a RAID migration
• Performing a strip size migration
• Performing a capacity expansion
• Performing a logical drive extension
• Erasing
• Spare part activation
Flashing amber/
green
The drive is a member of one or more logical drives and predicts the
drive will fail.
Flashing amber The drive is not configured and predicts the drive will fail.
Solid amber
The drive has failed.
Off
The drive is not configured by a RAID controller or a spare drive.
NVMe drive components and LEDs
Item
Description
1
Release lever
2
Activity ring
3
Do Not Remove LED
1
4
Request to Remove NVMe Drive button
1
Do not remove an NVMe SSD from the drive bay while the Do Not Remove button LED is flashing. The Do
Not Remove button LED flashes to indicate the device is still in use. Removal of the NVMe SSD before the
device has completed and ceased signal/traffic flow can cause loss of data.
60
Component identification
Содержание ProLiant XL230k Gen10
Страница 5: ...Warranty information 72 Regulatory information 73 Documentation feedback 73 5...
Страница 22: ...22 Customer self repair...
Страница 23: ...Customer self repair 23...
Страница 24: ...24 Customer self repair...
Страница 25: ...Customer self repair 25...
Страница 49: ...6 Install the riser cover 7 Install the riser into the I O module Removal and replacement procedures 49...
Страница 61: ...Chassis server bay numbering Chassis I O module bay numbering Component identification 61...
Страница 65: ...Cabling Front panel LED board assembly cabling SATA drive cabling Cabling 65...