Item
LED
Status
Definition
Flashing amber/green
The drive is a member of one or
more logical drives and predicts
the drive will fail.
Flashing amber
The drive is not configured and
predicts the drive will fail.
Solid amber
The drive has failed.
Off
The drive is not configured by a
RAID controller.
The blue Locate LED is behind the release lever and is visible when illuminated.
IMPORTANT:
The Dynamic Smart Array B140i Controller is only available in UEFI Boot Mode. It cannot be enabled in
Legacy BIOS Boot Mode. If the B140i controller is disabled, drives connected to the system board Mini-
SAS connectors operate in AHCI or Legacy mode. Under this condition:
• The drives cannot be a part of a hardware RAID or a logical drive.
• The Locate, Drive status, and Do not remove LEDs of the affected drives are disabled.
Use BIOS/Platform Configuration (RBSU) in the
B140i controller (System Configuration
®
BIOS/Platform Configuration (RBSU)
®
System Options
®
SATA Controller Options
®
Embedded SATA Configuration).
NVMe SSD components
Item
Component
Status
Definition
1
Release lever
—
Ejects the NVMe drive
carrier from the cage.
2
Activity ring LED
Rotating green
Off
Drive activity
No drive activity
3
Do Not Remove LED
Solid white
Drive is powered on and
configured in system.
Do not remove the drive.
Table Continued
98
NVMe SSD components
Содержание ProLiant ML350
Страница 12: ...12 Customer self repair...
Страница 13: ...Customer self repair 13...
Страница 14: ...14 Customer self repair...
Страница 15: ...Customer self repair 15...
Страница 25: ...Illustrated parts catalog 25...
Страница 64: ...SFF configuration Two SAS Expanders 64 Removal and replacement procedures...
Страница 91: ...Rack orientation 24 LFF drives Tower orientation Component identification 91...
Страница 93: ...Rack orientation One SAS expander configuration with LFF drives Tower orientation Component identification 93...
Страница 94: ...Rack orientation Two SAS expanders configuration with SFF drives Tower orientation 94 Component identification...
Страница 106: ...Storage controller installed in slot 6 to 9 106 Cabling...
Страница 114: ...LFF configuration SAS Expander cabling One SAS Expander LFF configuration 114 SAS Expander cabling...
Страница 115: ...SFF configuration Two SAS Expanders Cabling 115...