Press and hold the Power On/Standby button on the server.
c.
If the LEDs are off, check the power source. Then, power on the server again.
d.
If the power source is working properly, and the LEDs remain off, replace the power supply.
4.
Verify that the system has enough power, particularly if you recently added hardware, such as drives.
a.
To verify that the system has enough power, remove the newly added component.
b.
If the issue is no longer present, then additional power supplies are required.
c.
If the issue persists, check the IML for system information.
For more information, see the server documentation on the Hewlett Packard Enterprise website
(
http://www.hpe.com/info/enterprise-docs
).
More information
Product QuickSpecs on page 138
UPS issues
UPS is not working properly
Symptom
The UPS is not working properly.
Cause
• The UPS switch is not in the ON position.
• The UPS batteries are not charged to the proper level.
• The UPS software is not up-to-date.
• The UPS power cord is not connected.
• The UPS power cord is not the correct type for the UPS and the country/region in which the server is
located.
Action
1.
Be sure that the UPS batteries are charged to the proper level for operation.
For more information, see the UPS documentation.
2.
Be sure that the UPS power switch is in the ON position.
For the location of the switch, see the UPS documentation.
3.
Be sure that the UPS software is updated to the latest version.
Use the Power Management software on the Hewlett Packard Enterprise website (
4.
Be sure that the power cord is the correct type for the UPS and the country/region in which the server
is located.
For specifications, see the UPS reference guide.
74
UPS issues