For more information on how to review the Onboard Administrator SHOW ALL output for warnings or
possible failures, see the
HPE BladeSystem c-Class Enclosure Troubleshooting Guide
on the Hewlett
Packard Enterprise website (
http://www.hpe.com/support/BladeSystem_Enclosure_TSG_en
2.
To verify the status and diagnostics for the blade, access
Device bays > Host > Status
tab.
3.
Review the
IML
tab for possible server hardware events that require action.
4.
Review possible interconnect link state issues on the
Status
tab
> Port Mapping Information
.
Any Green indicator on a Port indicates that a link is available at the transportation layer. This means
that a NIC or a possible SAN connection should be established and that the midplane signals are
transferred correctly from the server to the interconnect device.
5.
The
Table view
tab on this screen displays the Port Status indicator as Green for all connections.
For any ports that are not green or that are failed ports, review the signal backplane on the server or
the midplane for damage.
For any blade power on issues, review the
iLO
screen on the
Status
tab and the
Event Log
tab on
the ”iLO – Device bay x” page.
6.
If all status indicators are green and no warnings, failed, or degraded components exist, then proceed
to the iLO WEB guide (
Status Tab > iLO > Web Administration
).
7.
If the blade is not displayed in the Insight Display on the chassis or within the Onboard Administrator
GUI, then troubleshoot the issue further using the procedures in the
HPE BladeSystem c-Class
Enclosure Troubleshooting Guide
on the Hewlett Packard Enterprise website (
support/BladeSystem_Enclosure_TSG_en
).
Using the OA CLI
To gather and respond to information obtained by the
SHOW ALL
command, perform the following
procedure.
Prerequisites
Gather and review health and system information using the OA CLI to troubleshoot the system:
• For systems using OA firmware 3.60 or later, run the
SHOW HEALTH
CLI command and review the
health status for the entire chassis. The
SHOW HEALTH
status output is included within the OA
SHOW
ALL
report as well as the first executed
SHOW
command.
• Execute the
SHOW ALL
command from either the OA GUI or the OA CLI as follows:
◦ OA GUI > Enclosure Settings > Configuration Scripts >
SHOW ALL
◦ OA CLI > Execute the following CLI command:
SHOW ALL
This command executes all OA CLI
SHOW
commands to provide a detailed report of the enclosure
configuration, status, and inventory available.
Procedure
1.
For systems using OA firmware 3.60 and earlier, review the
SHOW ENCLOSURE LCD
output of the
SHOW ALL
report. A display status of "Blinking" indicates a warning condition. Review the data or
remotely review messages on the Insight Display through the OA GUI.
2.
For a status overview of the chassis, review the output of the following commands listed in the
SHOW
ALL
report:
34
Using the OA CLI