Environmental specifications
Environmental specifications
Specifications
Specifications
Value
Value
Temperature range*
Temperature range*
—
Operating
10°C to 35°C (50°F to 95°F)
Nonoperating
-30°C to 60°C (-22°F to 140°F)
Relative humidity (noncondensing)
Relative humidity (noncondensing)
—
Operating
8% to 90%
28°C (82.4°F) maximum wet bulb temperature, noncondensing
Nonoperating
5% to 95%
38.7°C (101.7°F) maximum wet bulb temperature, noncondensing
Altitude
Altitude
—
Operating
3050 m (10,000 ft)
This value may be limited by the type and number of options installed.
Maximum allowable altitude change rate is 457 m/min (1,500 ft/min).
Nonoperating
9144 m (30,000 ft)
Maximum allowable altitude change rate is 457 m/min (1,500 ft/min).
Standard operating support
Standard operating support
10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C per every 305 m (1.8°F per every 1,000 ft) above sea level to a
maximum of 3,050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 20°C/hr
(36°F/hr). The upper limit and rate of
change may be limited by the type and number of options installed.
System performance during standard operating support might be reduced if operating above 30°C (86°F).
Extended ambient operating support
Extended ambient operating support
For approved hardware configurations, the supported system inlet range is extended to be: 5° to 10°C (41° to 50°F) and 35° to 40°C
(95° to 104°F) at sea level with an altitude derating of 1.0°C per every 175 m (1.8°F per every 574 ft) above 900 m (2,953 ft) to a
maximum of 3050 m (10,000 ft). The approved hardware configurations for this system are listed at the Hewlett Packard Enterprise
40°C to 45°C (104°F to 113°F) at sea level with an altitude derating of 1.0°C per every 125 m (1.8°F per every 410 ft) above 900 m
(2953 ft) to a maximum of 3,050 m (10,000 ft). The approved hardware configurations for this system are listed on the Hewlett
Environmental specifications
199
Содержание ProLiant DL20 Gen10 Plus
Страница 20: ...DIMM slot location The arrow points to the front of the server DIMM slot location 20 ...
Страница 30: ...Fan numbering Fan numbering 30 ...
Страница 100: ...Installing an optical drive in the LFF drive chassis 100 ...
Страница 154: ...Cabling This chapter includes cabling guidelines and diagrams for internal component cabling Cabling 154 ...
Страница 169: ...Energy pack cabling Energy pack cabling 169 ...
Страница 174: ...M 2 SATA SSD add in card cabling 174 ...
Страница 176: ...Fan cabling Color Description Orange Fan 1 cable Blue Fan 2 cable Gold Fan 3 cable Fan cabling 176 ...
Страница 177: ...Chassis intrusion detection switch cabling Chassis intrusion detection switch cabling 177 ...
Страница 178: ...Serial port cabling Serial port cabling 178 ...
Страница 180: ...Power supply cabling 180 ...
Страница 185: ...Troubleshooting NMI functionality Troubleshooting resources Troubleshooting 185 ...
Страница 196: ...Ukraine RoHS material content declaration Ukraine RoHS material content declaration 196 ...