9.
Using a T-30 Torx screwdriver, fully tighten each heatsink nut in the order indicated on the heatsink
label (1 > 2 > 3 > 4) until it no longer turns.
Front of Server
T30, 12 in-lbs
1
3
2
4
1
1
2
2
3
3
4
4
Must Install
Must Remove
Rear
Fully tighten
until screws
will not turn
Start
here
1
3
4
2
on page 25.
on page 23.
on page 42.
on page 21
HPE Trusted Platform Module 2.0 Gen10 option
Overview
Use these instructions to install and enable an HPE TPM 2.0 Gen10 Kit in a supported server blade. This
option is not supported on Gen9 and earlier server blades.
This procedure includes three sections:
1.
Installing the Trusted Platform Module board.
2.
Enabling the Trusted Platform Module.
3.
Retaining the recovery key/password.
HPE TPM 2.0 installation is supported with specific operating system support such as Microsoft
®
Windows Server
®
2012 R2 and later. For more information about operating system support, see the
product QuickSpecs on the Hewlett Packard Enterprise website (
). For more
information about Microsoft
®
Windows
®
BitLocker Drive Encryption feature, see the Microsoft website
(
CAUTION:
If the TPM is removed from the original server blade and powered up on a different
server blade, data stored in the TPM including keys will be erased.
68
Hardware options installation