59
IMPORTANT:
•
The HPE 5940 48SFP+ 6QSFP28, HPE 5940 48XGT 6QSFP28, HPE 5940 48XGT 6QSFP+,
HPE 5940 48SFP+ 6QSFP+, HPE 5940 , and HPE 5940 2-slot switches can operate
correctly with only one power supply. You can install two power supplies on the switch for 1+1
redundancy.
•
The HPE 5940 4-slot switch can operate correctly with two power supplies. You can install four
power supplies on the switches for 2+2 redundancy.
•
You must install two fan trays of the same model for the switch.
•
If an HPE 5940 48SFP+ 6QSFP+ or HPE 5940 48SFP+ 6QSFP28 switch uses 650 W power
supplies, you can install two LSWM1HFANSC, LSWM1HFANSCB, LSWM1FANSC, or
LSWM1FANSCB fan trays to ensure heat dissipation. If an HPE 5940 48SFP+ 6QSFP+ switch
uses 300 W power supplies, you must install two LSWM1FANSC or LSWM1FANSCB fan trays to
ensure heat dissipation.
Power supplies
CAUTION:
When the switch has power supplies in redundancy, you can replace a power supply without
powering off the switch. Make sure the power supply to be replaced is powered off before you
replace it.
Table 13 Power supply specifications
Power supply
Specifications
Remarks
650W AC
•
Rated input voltage:
100 VAC to 240 VAC @ 50 Hz or 60 Hz
•
Max input voltage:
90 VAC to 264 VAC @ 47 Hz to 63 Hz
•
Max output power:
650 W
For more information about the
power supplies, see
HPE A58x0AF
650W AC (JC680A) & 650W DC
(JC681A) Power Supplies User
Guide
or
HPE FlexFabric Switch
650W 48V Hot Plug NEBS
Compliant DC Power Supply
(JH336A) User Guide.
650W DC
•
Rated input voltage:
–40 VDC to –60 VDC
•
Max input voltage:
–40 VDC to –72 VDC
•
Max output power:
650 W
300W AC
•
Rated input voltage:
100 VAC to 240 VAC @ 50 Hz or 60 Hz
•
Max input voltage:
90 VAC to 264 VAC @ 47 Hz to 63 Hz
•
Max output power:
315 W
For more information about the
power supplies, see
HPE A58x0AF
300W AC (JG900A) & 300W DC
(JG901A) Power Supplies User
Guide.
300W DC
•
Rated input voltage:
–48 VDC to –60 VDC
•
Max input voltage:
–36 VDC to –72 VDC
•
Max output power:
315 W