103
track nqa
Use
track nqa
to create a track entry and associate it with the specified reaction entry of the NQA
test group.
Use
undo track
to remove the track entry.
Syntax
track
track-entry-number
nqa entry
admin-name
operation-tag
reaction
item-number
[
delay
{
negative
negative-time
|
positive
positive-time
} * ]
undo track
track-entry-number
Default
No track entry exists.
Views
System view
Predefined user roles
network-admin
mdc-admin
Parameters
track-entry-number
: Specifies the track entry ID in the range of 1 to 1024.
entry
admin-name operation-tag
: Specifies the NQA test group to be associated with the track entry.
The
admin-name
argument is the name of the NQA test group administrator who creates the NQA
operation, and is a case-insensitive string of 1 to 32 characters. The
operation-tag
argument is the
NQA operation tag, a case-insensitive string of 1 to 32 characters.
reaction
item-number
: Specifies the reaction entry to be associated with the track entry. The
item-number
argument is the reaction entry ID in the range of 1 to 10.
delay
: Specifies the amount of time the Track module waits before notifying the application modules
that the track entry state has changed. If this keyword is not specified, the Track module notifies the
application modules immediately when the track entry state changes.
negative
negative-time
: Specifies the amount of time the Track module waits before notifying the
application modules that the state of the track entry has changed to Negative. The
negative-time
argument represents the delay time in the range of 1 to 300 seconds.
positive
positive-time
: Specifies the amount of time the Track module waits before notifying the
application modules that the state of the track entry has changed to Positive. The
positive-time
argument represents the delay time in the range of 1 to 300 seconds.
Usage guidelines
After a track entry is created, you can only use the
track nqa delay
command to modify its
notification delay settings. To modify other settings, you must delete the entry and create a new one.
Examples
# Create track entry 1, and associate it with reaction entry 3 of the NQA test group
admin-test
.
<Sysname> system-view
[Sysname] track 1 nqa entry admin test reaction 3
Related commands
display track