a.
RAID Controller firmware
b.
RAID driver
c.
Host bus adapter firmware
3.
Be sure the drive or backplane is cabled properly.
4.
Be sure the drive data cable is working by replacing it with a known functional cable.
5.
Be sure drive blanks are installed properly when the server is operating. Drives may overheat and
cause sluggish response or drive failure.
6.
Be sure the replacement drives within an array are the same size or larger.
7.
Be sure the replacement drives within an array are the same drive type, such as SAS, SATA, or SSD.
8.
Power cycle the server. If the drive shows up, check to see if the drive firmware needs to be updated.
Drives are not recognized
Symptom
Drives are not recognized
Action
1.
Be sure no power issues exist.
2.
Be sure no loose connections exist.
3.
Check for available updates on any of the following components:
a.
RAID Controller firmware
b.
RAID driver
c.
HBA firmware
4.
Be sure the drive or backplane is cabled properly.
5.
Check the drive LEDs to be sure they indicate normal function.
6.
Be sure the drive is supported. Power cycle the server. If the drive appears, check to see if the
drive firmware needs to be updated.
7.
Be sure the drive bay is not defective by installing the hard drive in another bay.
8.
When the drive is a replacement drive on an array controller, be sure that the drive is the same type
and of the same or larger capacity than the original drive.
9.
When using an array controller, be sure the drive is configured in an array.
10.
Be sure that the correct controller drivers are installed and that the controller supports the hard drives
being installed.
Data is inaccessible
Symptom
The data on the drives is inaccessible.
Troubleshooting
35
Содержание Cloudline CL2600 Gen10
Страница 62: ...VLAN Configuration Parameter Description Enter Configuration Menu VLAN VLAN Configuration 62 System utilities...
Страница 63: ...Driver Health Parameter Description Component UEFI driver Driver healthy status System utilities 63...
Страница 73: ...NVMe SSD Drives List System utilities 73...
Страница 103: ...b Remove the riser blank Full height Removal and replacement procedures 103...