8.
Install the access panel.
9.
Install the server in the rack.
10.
Connect each power cord to the server.
11.
Connect each power cord to the power source.
12.
Power up the server (
).
Installing a high-performance heatsink
Prerequisites
CAUTION:
Installing a high-performance heatsink requires the installation of a processor assembly
onto the heatsink. To avoid damage to server or components, do not remove or install the processor
assembly when installing or replacing other heatsinks.
Before installing this option, be sure that you have the following:
• The components included with the hardware option kit
• T-30 Torx screwdriver
• 1/4" flat blade screwdriver or nonconductive tool
Hewlett Packard Enterprise recommends using a nonconductive tool.
Procedure
1.
Observe the following alerts.
CAUTION:
The processor assembly must be removed and replaced as a unit. Do not remove
the processor from the carrier.
Removal and replacement procedures
113