WBEM indication providers
Hardware monitors are available to monitor the following components (These monitors are distributed
free on the OE media):
Server/fans/environment
CPU monitor
UPS monitor*
FC hub monitor*
FC switch monitor*
Memory monitor
Core electronics components
Disk drives
Ha_disk_array
NOTE:
No SysFaultMgmt WBEM indication provider is currently available for components followed by an
asterisk.
OpenVMS fault management and monitoring
HPE WBEM Provider software enables monitoring the health of Integrity servers running OpenVMS. More
information on WBEM providers is available at
Web Based Enterprise Services (WEBES) suite of tools aids monitoring and diagnosing the OpenVMS
systems.
http://www.hpe.com/support/WEBES_Overview
See the
HPE OpenVMS System Manager's Manual, Volume 2: Tuning, Monitoring, and
Complex Systems
document for OpenVMS specific monitoring tips available at
(search for the manual title).
Errors and reading error logs
Event log definitions
Often the underlying root cause of an MCA event is captured by system or iLO MP firmware in both the
System Event and Forward Progress Logs (SEL and FPL, respectively). These errors are easily matched
with MCA events by their timestamps. For example, the loss of a processor VRM might cause a
WBEM indication providers
105
Содержание AH395-9013J
Страница 13: ...Internal components Figure 1 Internal components Fans Processors DIMM expansion boards Internal components 13...
Страница 19: ...21 NIC 3 connector 22 NIC 4 connector 23 NIC link LED 24 NIC activity LED Overview 19...
Страница 186: ...2 Select Add License Key 3 Enter the license key and press Enter 186 Utilities...