background image

E

n

s

u

re

 F

la

n

g

e

 

is

 t

ig

h

t

K

e

y

 V

a

lv

e

Ga

s

 I

n

W

a

rn

in

g

:

It

 i

s

 t

h

e

 i

n

s

ta

lle

rs

 r

e

s

p

o

n

s

ib

ilt

y

 t

o

 

e

n

s

u

re

 k

e

y

 v

a

lv

e

 a

n

d

 b

ra

c

k

e

a

re

 s

e

c

u

re

ly

 m

o

u

n

te

d

.

F

a

ilu

re

 t

o

 d

o

 s

o

 m

a

y

 r

e

s

u

lt

 i

n

 i

n

ju

ry

 o

p

ro

p

e

rt

y

 d

a

m

a

g

e

D

o

 N

o

U

s

e

 

T

h

re

a

d

 /

 P

ip

e

 s

e

a

le

o

n

 f

la

re

 f

it

ti

n

g

s

.

F

le

x

 L

in

e

 -

 D

o

 n

o

k

in

k

.

M

a

in

ta

in

 l

a

rg

e

 r

a

d

iu

s

 

to

 a

v

o

id

 w

h

is

tl

in

g

.

E

x

c

e

s

s

 F

lo

w

 V

a

lv

e

(I

m

p

o

rt

a

n

t:

 I

n

s

ta

ll

 E

F

V

 V

a

lv

e

 i

n

 a

h

o

ri

z

o

n

ta

p

o

s

it

io

n

 o

n

ly

.)

P

e

rf

o

rm

 L

e

a

k

 T

e

s

t:

1

A

In

s

ta

lla

ti

o

n

2

A

n

n

u

a

lly

3

A

n

y

ti

m

e

 a

 g

a

s

 l

e

a

k

 i

s

 s

u

s

p

e

c

te

d

F

o

ll

o

w

 a

ll

 I

n

s

tru

c

ti

o

n

s

 a

n

d

 L

o

c

a

C

o

d

e

s

D

o

 n

o

u

s

e

 t

h

re

a

d

 s

e

a

le

p

ip

e

 s

e

a

le

o

n

 

  

 f

la

re

 f

it

ti

n

g

s

.

D

o

 n

o

c

h

a

n

g

e

 p

ro

d

u

c

fro

m

 i

ts

 o

ri

g

in

a

l

  

c

o

n

fi

g

u

ra

ti

o

n

 

M

o

d

if

ic

a

ti

o

n

 o

p

ro

d

u

c

w

il

v

o

id

 a

n

y

 

  

c

e

rt

if

ic

a

ti

o

n

 a

n

d

 w

a

rra

n

ty

M

a

tc

h

-L

it

 S

y

s

te

m

 W

it

h

 F

le

x

 L

in

e

0

2

/0

8

/2

0

1

6

Содержание MLFPK 18-SQ

Страница 1: ...jury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance DANGER If you smell gas 1 Shut off g...

Страница 2: ...for use with any type of remote or start up timer control WARNING We suggest that our products be installed by professionals that are locally licensed by the authority having jurisdiction in gas piping We suggest that our products be serviced annually by a professional certified in the US by the National Fireplace Institute NFI as NFI Gas Specialists or in Canada by WETT Wood Energy Technical Trai...

Страница 3: ... pit to allow for emergency shut off and maintenance WARNING Use non combustible materials and construction for gas supply power and enclosure A metal outlet box should be used inside the enclosure for electronic ignition models WARNING The enclosure must incorporate 1 vent on at least two opposing sides 2 vents total at a minimum size of 18 sq inches of total free area each Example 3 x 6 or large...

Страница 4: ...t on main gas supply Repair leaks as necessary Shut Off Gas Supply and Power to fire pit Connect fire pit to main gas supply Turn on gas supply and perform leak test on all inlet connections Repair as needed Position fire pit safely with access to all gas connections for testing Light fire pit It may take several cycles to purge air from the lines Once fire pit is lit perform leak test on all gas ...

Страница 5: ... fire pit per instructions 2 Fill Pan with glass Cover Burner with 1 8 to of glass Do not over fill with glass All LP installations must be checked for back pressure with media installed Failure to do so may result in personal injury or property damage 6 Parts List 1 Match Lit Fire Pit 2 Lava Rock 3 Instructions 7 Installation WARNING Product certification is void if product configuration is alter...

Страница 6: ...t for cooking Make sure that there is no vegetation or other objects over the top or sides of the fire pit that could interfere with safe operation See clearances in section 2 Selecting the Location WARNING If lava rock is wet allow fire pit to burn for 45 minutes prior to coming within 15 feet of the fire pit WARNING When fire pit is not in operation turn off gas valve WARRANTY REQUIREMENT When n...

Страница 7: ...by manufacturer 10 Troubleshooting Below are some potential causes and countermeasures to the symptoms indicated in bold Please contact your retailer or certified technician for service repair Below are some potential causes and countermeasures to the symptoms indicated in bold If still unable to resolve issue please contact your retailer or certified technician Will Not Light 1 Air in gas line If...

Страница 8: ...OB Dayton Ohio This warranty is for parts and in house HPC labor The defective product must be sent back to HPC with a Return Merchandise Authorization RMA issued by HPC for that specific product and any other additional information for the nature of the defect or warranty claim The warranty does not cover items that have been damaged by overheating modification abuse or improper storage Also any ...

Страница 9: ...9 6 05 2015 870 ...

Страница 10: ...kink Maintain large radius to avoid whistling Excess Flow Valve Important Install EFV Valve in a horizontal position only Perform Leak Test 1 At Installation 2 Annually 3 Anytime a gas leak is suspected Follow all Instructions and Local Codes Do not use thread sealer pipe sealer on flare fittings Do not change product from its original configuration Modification of product will void any certificat...

Отзывы: