Edit Ports window
Description
Item
Select the attribute of the port indicating I/O flow.
Port Attribute
•
Initiator: Issues I/O commands to a target port when I/O is executed
between storage systems with Continuous Access Synchronous, and so
on.
•
Target: Receives I/O commands from a host.
•
RCU Target: Receives I/O commands from an initiator when I/O is
executed between storage systems with Continuous Access Synchronous,
and so on.
•
External: Issues I/O commands to a target port of an external storage
system with External Storage.
If this port attribute is changed from Target or RCU Target to Initiator or to
External, the host group of this port belongs to meta_resource.
Therefore, the host group of this port is not displayed in windows.
Select whether LUN security is Enabled or Disabled.
Port Security
Select the data transfer speed, in Gbps, for the selected fibre channel port.
Port Speed
If
Auto
is selected, the storage system automatically sets the data transfer
speed to 2, 4, 8, 10, or 16 Gbps.
Caution
: If you are using 2-Gbps HBA and switch, set the transfer speed of
the CHF (fibre channel adapter) port as 2 Gbps. If you are using 4-Gbps
HBA and switch, set the transfer speed of the CHF port as 4 Gbps. If you
are using 8-Gbps HBA and switch, set the transfer speed of the CHF port
as 8 Gbps. If you are using 16-Gbps HBA and switch, set the transfer speed
of the CHF port as 16-Gbps. If the Auto Negotiation setting is required, the
linkup may become improper at server restart. Check a channel lamp, and
if it is blinking, remove and re-insert the cable to perform the signal
synchronization and linkup.
When the transfer speed of the CHF port is set to
Auto
, the data might not
be transferred at the maximum speed depending on the connected device.
Confirm the transfer speed appearing in
Speed
in the
Ports
list when you
start up the storage system, HBA, or switch. When the transfer speed is not
the maximum speed, select the maximum speed from the list on the right or
remove and reinsert the cable.
When the transfer speed of the CHF port is set to
Auto
, the data might not
be transferred at the maximum speed depending on the connected device.
Confirm the transfer speed appearing in
Speed
in the
Ports
list when you
Edit Ports wizard 405
Содержание XP7
Страница 229: ...Select LDEVs window Available LDEVs table Description Item LDEV identifiers LDEV ID Create Resource Groups wizard 229 ...
Страница 303: ...Pools Volume tabs Pools Volume tabs 303 ...
Страница 378: ...Add LUN Paths wizard Select LDEVs window Available LDEVs table 378 LUN Manager GUI reference ...
Страница 381: ...Select Host Groups window Available Host Groups table Add LUN Paths wizard 381 ...