[XP7]
•
(1) In the case of virtual DKC, if Host group name: HP-VSS-HG does not exist in RSG which
P-VOL belongs to, create HP-VSS-HG.
•
(2) If virtual DKC is running, confirm the setting when VSS provider is used in the virtual
DKC. See Table 9-1.
•
(3) If the virtual DKC which straddles multiple physical DKCs is used, make sure that the
virtual LDEV ID of P-VOL is not duplicated in the virtual DKC. If the virtual LDEV ID of P-VOL
is duplicated, assign the virtual LDEV ID of P-VOL to prevent duplication.
E200201C
Message
The LU is not found.
Explanation
While waiting for format completion, S-VOL is not found.
Recommended action
During S-VOL creation, operation might have been interrupted by Storage Management Software
or another program, and the P-VOL or S-VOL may have been deleted or the pair state may have
been changed. Confirm the existence of P-VOL and S-VOL and check the pair status using
Storage Management Software.
E200201D
Message
DeleteLun failed for S-Vol: [LU number of S-VOL].
Explanation
Could not delete an S-VOL.
Recommended action
An error occurred when an operation command was given to the disk array system.
See
“About errors attributable to disk array systems” (page 133)
E200201E
Message
Initializing S-Vol LU failed.
Explanation
Initialization of an S-VOL failed.
Recommended action
•
(1) During S-VOL creation, operation might have been interrupted by other program, and
the P-VOL or S-VOL may have been deleted or the pair state may have been changed.
Confirm the existence of P-VOL and S-VOL and check the pair status using Storage
Management Software.
•
(2) An error occurred when an operation command was given to the disk array system.
See
“About errors attributable to disk array systems” (page 133)
108
Troubleshooting
Содержание XP
Страница 51: ...5 Missing number 51 ...