2.
Rotate the bezel and snap in at the bottom.
Reinstall the module in the library
Procedure
1.
Slide the module into the rack.
2.
If there are adjacent modules:
a.
Set the alignment mechanisms to the lock position.
If you encounter resistance, adjust the upper module so the pin in the alignment mechanism moves
into the hole in the lower module.
b.
Reconnect the expansion interconnect cables.
3.
Use a #2 Phillips screwdriver to tighten the captive fasteners on each side of the repaired module and
its adjacent modules until they are finger tight. Do not over tighten.
4.
Insert the magazines.
5.
Reconnect the Ethernet, SAS, and Fibre Channel cables to the module.
6.
Reconnect the power supply cables to the module.
Verifying the center bezel replacement
Procedure
1.
Check the overall library status from the RMI
Status > Library Status
screen.
If there are any new events, verify that the cables and cords are properly installed. In a library with
multiple modules, verify that the alignment mechanisms between modules are locked and that the
bottom alignment mechanism is unlocked.
2.
Verify that the library configuration is correct from the RMI
Status > Partition Map > Configuration
Status
screen.
150
Reinstall the module in the library