Removal and Replacement Procedures
2-4
HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guide
HP CONFIDENTIAL
Codename: Aurora Part Number: 251850-004 Last Saved On: 9/19/03 10:57 AM
System Power Down
WARNING: To reduce the risk of personal injury, electric shock, or damage to the
equipment, remove the power cord to remove power from the system. The front panel
Power On/Standby button does not completely shut off system power. Portions of the
power supply and some internal circuitry remain active until AC power is removed.
IMPORTANT:
If installing a hot-plug device, it is not necessary to power down the system.
To power down the system:
1. Power down any attached servers. Refer to the server documentation.
2. Press the Power On/Standby button. Wait for the system power LED to go from green to
off.
3. Disconnect the power cords.
Hard Drive Blank
CAUTION:
Always populate drive bays with either a hard drive or blank. Proper airflow can
only be maintained when the bays are populated. Operating the system with unpopulated
drive bays can lead to improper cooling and thermal damage.
To remove the component:
2
1
To replace a blank, slide the blank into the bay until it locks into place.