Table 9 SAS and SATA hard drive LED combinations
Online/activity
LED (green)
Fault/UID LED
(amber/blue)
Interpretation
On, off, or
fl
ashing
Alternating amber
and blue
The drive has failed, or a predictive failure alert has been
received for this drive; it also has been selected by a
management application.
On, off, or
fl
ashing
Steadily blue
The drive is operating normally, and it has been selected by
a management application.
On
Amber,
fl
ashing
regularly (1 Hz)
A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.
On
Off
The drive is online, but it is not active currently.
Flashing regularly
(1 Hz)
Amber,
fl
ashing
regularly (1 Hz)
Do not remove the drive. Removing a drive may terminate
the current operation and cause data loss.
The drive is part
of an array that is undergoing capacity expansion or stripe
migration, but a predictive failure alert has been received for
this drive. To minimize the risk of data loss, do not replace
the drive until the expansion or migration is complete.
Flashing regularly
(1 Hz)
Off
Do not remove the drive. Removing a drive may terminate the
current operation and cause data loss.
The drive is rebuilding,
or it is part of an array that is undergoing capacity expansion
or stripe migration.
Flashing irregularly
Amber,
fl
ashing
regularly (1 Hz)
The drive is active, but a predictive failure alert has been
received for this drive. Replace the drive as soon as possible.
Flashing irregularly
Off
The drive is active, and it is operating normally.
Off
Steadily amber
A critical fault condition has been identi
fi
ed for this drive,
and the controller has placed it of
fl
ine. Replace the drive as
soon as possible.
Off
Amber,
fl
ashing
regularly (1 Hz)
A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.
Off
Off
The drive is of
fl
ine, a spare, or not con
fi
gured as part of an
array.
All-in-One SB600c Storage Blade Solution
47
Содержание StorageWorks All-in-One SB600c - Storage Blade
Страница 36: ...36 Hardware Options installation and cabling ...
Страница 40: ...40 Configuration utilities ...
Страница 50: ...50 All in One SB600c Storage Blade Solution components ...
Страница 58: ...58 Regulatory Compliance Notices and Safety ...