Diagnostics
99
17
A director firmware upgrade is required (“
Download a Firmware Version to a
” on page 210). Perform the data collection procedure after the download.
Did the director-to-HAFM appliance Ethernet connection recover?
NO
YES
↓
The director-to-HAFM appliance connection is restored and is
operational. Exit MAP.
Contact the next level of support. Exit MAP.
18
An instance of the HAFM application is open at another HAFM appliance and
communicating with the director (duplicate session). Notify the customer and
either:
■
Power off the HAFM appliance running the second instance of the
application, or
■
Configure the HAFM appliance running the second instance of the
application as a client workstation.
Does the customer want the second HAFM appliance configured as a client?
YES
NO
↓
Power off the HAFM appliance reporting the Duplicate Session
communication problem. Exit MAP.
19
Determine the internet protocol (IP) address of the HAFM appliance running the
first instance of the HAFM application.
1. After successful POST completion, the LCD panel displays a
Welcome!!
message, then continuously cycles through and displays appliance operational
information.
■
Host name.
■
System date and time.
■
LAN 1 and LAN 2 IP addresses.
■
Fan 1, fan 2, fan 3, and fan 4 rotational speed.
■
CPU temperature.
Содержание StorageWorks 2/140 - Director Switch
Страница 18: ...About this Guide 18 Director 2 140 Service Manual ...
Страница 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Страница 224: ...FRU Removal and Replacement 224 Director 2 140 Service Manual Figure 72 ESD grounding points 1 ...
Страница 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Страница 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Страница 318: ...Information and Error Messages 318 Error Messages ...
Страница 388: ...Event Code Tables 388 Director 2 140 Service Manual ...