Diagnostics
65
Figure 16: View FRU Properties panel
2. Inspect the Status fields for both power supplies.
Does the Status field display a
Failed
message for either power supply?
NO
YES
↓
A power supply failure is indicated. Go to
codes. If no event codes are found, go to “
” on page 69. Exit MAP.
51
Inspect the Status fields for director FRUs, including CTP cards, SBAR
assemblies, fan modules, and the backplane.
Does the Status field display a
Failed
message for any of the FRUs?
YES
NO
↓
The director is operational. Exit MAP.
A FRU failure is indicated. Continue to the next step to obtain event codes. If no
event codes are found, go to “
MAP 0500: FRU Failure Analysis
Exit MAP.